Preferred Language
Articles
/
jmracpc-38
STUDY THE OPTIMUM CONDITIONS FOR THE REMOVAL OF HEAVY METAL ELEMENTS FROM AQUEOUS SOLUTIONS USING CONTAMINATED BACTERIA Bacillus subtilis LOCALLY ISOLATED: STUDY THE OPTIMUM CONDITIONS FOR THE REMOVAL OF HEAVY METAL ELEMENTS FROM AQUEOUS SOLUTIONS USING CONTAMINATED BACTERIA Bacillus subtilis LOCALLY ISOLATED
...Show More Authors

We studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 106 cell/ml showed maximum removal for two isolates. The removal efficiency was (%) under the obtained optimum conditions above using the bacterial isolate
Bacillus subtilis 88.4, 91.9, 98.1, 96.7, 83.1, and 94.8 for the minerals Cd, Cu, Pb, Fe, Zn and Ni consequently. The maximum removal for Cr element under the optimum conditions was 92.1% by using Bacillus subtilis 2 isolate.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 20 2022
Journal Name
Nano Biomedicine And Engineering
DFT-Quantum Chemical and Experimental Studies of a New 2-(Substituted Thio) Furan as a Corrosion Inhibitor in Acidic Media
...Show More Authors

The corrosion inhibiting properties of the new furan derivative 5-(furan-2-ylmethylsulfonyl-4-phenyl-2,4- dihydro [1,2,4] triazole-3-thione in acidic solution (1.0 M HCl) were explored utilizing electrochemical, surface morphology (AFM), and quantum chemical calculations approaches. The novel furan derivative 5-(furan-2-ylmethylsulfonyl-4-phenyl-2,4- dihydro [1,2,4] triazole-3-thione shows with an inhibitory efficiency value of 99.4 percent at 150 ppm, carbon steel corrosion in acidic medium is effectively inhibited, according to the results. The influence of temperature on corrosion prevention was studied using adsorption parameters and activation thermodynamics. The novel furan derivative creates a protective layer over the metallic surfa

... Show More
View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
المربعات الصغرى المشذبة الموزونة لتقدير تأثير مياه الصرف الصحي في تلوث مياه نهر دجلة/ محافظة واسط
...Show More Authors

في كثير من الأحيان يفشل تحليل المربعات الصغرى (LS) تماماً في حالة وجود قيم شاذة في الظواهر المدروسة، اذ ستفقد OLS خصائصها ومن ثم تفقد صفة المقدر الخطي الجيد Beast Linear Unbiased Estimator (BLUE) لِما تسببه الشواذ Outliers من تأثير سيئ علـى نتـائج التحليـل الاحـصائي للبيانـات اذ أن وجودها يؤدي الى إرباك كبير في تحليل البيانات في حالة إستخدام الطرائق التقليدية، ولعلاج هذه المشكلة تم تطوير أساليب إحصائية جديدة بحيث لا تتأثر بالقي

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Performance evolution of a hybrid thermal solar air conditioning system and compare it with a traditional system according to Iraq weather
...Show More Authors

In a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Photodynamic effect of Rose Bengal activated by low-level laser light on S. aureus : Qusay K. Abbas*, Layla M. Hassan
...Show More Authors

Abstract: Background: Staphylococcus aureus is Gram-positive bacteria that lives as a normal flora in living organisms but can be pathogenic to humans. Although a relatively unspectacular, nonmotile coccoid bacterium, S. aureus is a dangerous human pathogen in both community-acquired and nosocomial infections. Due to the increasing emergence of new strains of this antibiotic-resistant bacteria, it has become essential to approach different methods to control this pathogen. One of these methods is the antimicrobial photodynamic inactivation process using a low-level laser, in this paper, the Photodynamic effects of Rose Bengal and LLLL on the virulence factors of S.aureus were evaluated.

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 20 2023
Journal Name
Bionatura
Impact of inflammatory markers, dread diseases and cycle threshold (Ct) Values in COVID-19 progression. Revis Bionatura 2023; 8 (1) 33
...Show More Authors

Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Numerical modeling of single closed and open-ended pipe pile embedded in dry soil layers under coupled static and dynamic loadings
...Show More Authors
Abstract<p>For the design of a deep foundation, piles are presumed to transfer the axial and lateral loads into the ground. However, the effects of the combined loads are generally ignored in engineering practice since there are uncertainties to the precise definition of soil–pile interactions. Hence, for technical discussions of the soil–pile interactions due to dynamic loads, a three-dimensional finite element model was developed to evaluate the soil pile performance based on the 1 g shaking table test. The static loads consisted of 50% of the allowable vertical pile capacity and 50% of the allowable lateral pile capacity. The dynamic loads were taken from the recorded data of the Kobe e</p> ... Show More
Scopus (12)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Mar 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of Some Mixed-Ligand Complexes Containing Azo Dye and 1,10-phenanthroline with CoII, ZnII, CdII and HgII Ions
...Show More Authors

 In this work, the ligand was obtained from the reaction of diazonium salt of naphthyl amine with 1-amino-2-naphtol-4-sulfonic acid. The bidentate ligand  type (NO) donar atoms was reacted with 1,10-phenanthroline and matel salt in a 1:1:1 mole ratio to give the complexes, using NaOH as a base. Physical-chemical teqnichas were used to characteriz the prepared compounds FT-IR,U.V-Vis, fluorescence and 1HNMR spectroscopy, atomic absorption , chloride content along with conductivity and melting point measurements .Finally, thermal analysis was used to confirm the presence of coordination H2O molecule in the complexes structure. According to memtioned characterization methods, the general formula proposed for CoII ZnII, CdII and Hg

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Unstable Angina /Non ST Elevation Myocardial Infarction: Frequency of Conventional Risk Factors; TIMI Risk Score, and Their Impact On Angiographic Data
...Show More Authors

Background: Appreciation of the crucial role of risk factors in the development of coronary artery disease (CAD) is one of the most significant advances in the understanding of this important disease. Extensive epidemiological research has established cigarette smoking, diabetes, hyperlipidemia, and hypertension as independent risk factors for CADObjective: To determine the prevalence of the 4 conventional risk factors(cigarette smoking, diabetes, hyperlipidemia, and hypertension) among patients with CAD and to determine the correlation of Thrombolysis in Myocardial Infarction (TIMI) risk score with the extent of coronary artery disease (CAD) in patients with unstable angina /non ST elevation myocardial infarction (UA/NSTEMI).Methods: We

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 20 2021
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Hall and Joule's heating Influences on Peristaltic Transport of Bingham plastic Fluid with Variable Viscosity in an Inclined Tapered Asymmetric Channel
...Show More Authors

   This paper presents an investigation of peristaltic flow of Bingham plastic fluid in an inclined tapered asymmetric channel with variable viscosity. Taken into consideration Hall current, velocity, thermal slip conditions, Energy equation is modeled by taking Joule heating effect into consideration and by holding assumption of long wavelength and low Reynolds number approximation these equations simplified into couple of non-linear ordinary differential equations that solved using perturbation technique. Graphical analysis has been involved for various flow parameters emerging in the problem. We observed two opposite behaviors for Hall parameter and Hartman number on velocity axial and temperature curves.

View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Effect of Adding Alcohols and Gas Velocity on Gas Hold up and Mass Transfer Coefficient in Bubble Columns with Draught Tube
...Show More Authors

     The bubble columns are widely used as a two or three phase reactor in industrial chemical process such as absorption, biochemical reactions, coal liquefaction, etc. To design such a column, two main parameters should be taken in consideration, the gas hold-up (), and the liquid phase mass transfer coefficient KLa. The study includes the effect of gas velocity and the addition of alcohols on gas hold-up and mass transfer coefficient in bubble column with draught tube when the length of the column is 1.5m and the ratio of the draught tube diameter to the column diameter equals 0.5 and the air dispersion into the base of the draught tube using a multi hole tuyere is equivalent to a diameter of 0.15 mm and

... Show More
View Publication Preview PDF