Background: Increasing interest in quality of life (QoL) is the new approach for understanding and improvement of health care. Although there are many studies about quality of life, there is deficiency of data about quality of life of peoples survived from terroristic explosions.Objectives: To study the QoL for peoples survived from terroristic explosions and compare it with that of a controlled people. Methods: This study was conducted between, 1st of July till 31st of December 2013. The sample of this study was collected from peoples attending the outpatient clinics in four primary health care centers, Baghdad city (2 from Rusafa and 2 from Karkh). 183 individuals proved to be exposed to terroristic explosion and 199 individual not exposed to such event were recruited and Arabic version of the World Health Organization (WHO) self-reporting questionnaire (WHO-QoL-BRIEF) was used to assess the QoL.Results: This study revealed that peoples exposed to event of terroristic explosion show a serious defect in all domains of QoL (physical, psychological, social and environmental) as compared with that for non exposed peoples to such accidents in the same areas of the study.Conclusions: This study showed that peoples survived from terroristic explosions have a low QoL indicators as compared with those not exposed to such trauma .
Quinolones L1 (ciprofloxacin) are manufactured wide range anti-infection agents with great oral ingestion and magnificent bioavailability. Because of the concoction capacities found on their core (a carboxylic corrosive capacity at the 3-position) and much of the time an essential piperazinyl ring (or anothertN-heterocycle) at the 7-positionh and a carbonylvoxygenc atomi atothel 4-positioni) quinolones bind metal particlesiframing buildings which can go about as bidentate. Bidentateiligands L2=2-phenyl-2-(P-methoxy anilinee) acetonitrilel was set up by the response of Primiryiaminejwithjbenzaldehyde, in nearness of potassiumbcyanidej and acidicimedia . Theimetalledifices were portrayed by the miniaturized scale component examination (C.H
... Show MoreThe dependence of the energy losses or the stopping power for the energies and the related penetrating factor are arrive by using a theoretical approximation models. in this work we reach a compatible agreement between our results and the corresponding experimental results.
The downhole flow profiles of the wells with single production tubes and mixed flow from more than one layer can be complicated, making it challenging to obtain the average pressure of each layer independently. Production log data can be used to monitor the impacts of pressure depletion over time and to determine average pressure with the use of Selective Inflow Performance (SIP). The SIP technique provides a method of determining the steady state of inflow relationship for each individual layer. The well flows at different stabilized surface rates, and for each rate, a production log is run throughout the producing interval to record both downhole flow rates and flowing pressure. PVT data can be used to convert measured in-situ r
... Show More
In this work, the modified Lyapunov-Schmidt reduction is used to find a nonlinear Ritz approximation of Fredholm functional defined by the nonhomogeneous Camassa-Holm equation and Benjamin-Bona-Mahony. We introduced the modified Lyapunov-Schmidt reduction for nonhomogeneous problems when the dimension of the null space is equal to two. The nonlinear Ritz approximation for the nonhomogeneous Camassa-Holm equation has been found as a function of codimension twenty-four.
The downhole flow profiles of the wells with single production tubes and mixed flow from more than one layer can be complicated, making it challenging to obtain the average pressure of each layer independently. Production log data can be used to monitor the impacts of pressure depletion over time and to determine average pressure with the use of Selective Inflow Performance (SIP). The SIP technique provides a method of determining the steady state of inflow relationship for each individual layer. The well flows at different stabilized surface rates, and for each rate, a production log is run throughout the producing interval to record both downhole flow rates and flowing pressure. PVT data can be used to convert measured in-situ rates
... Show MoreOur aim in this paper is to introduce the notation of nearly primary-2-absorbing submodule as generalization of 2-absorbing submodule where a proper submodule of an -module is called nearly primary-2-absorbing submodule if whenever , for , , , implies that either or or . We got many basic, properties, examples and characterizations of this concept. Furthermore, characterizations of nearly primary-2-absorbing submodules in some classes of modules were inserted. Moreover, the behavior of nearly primary-2-absorbing submodule under -epimorphism was studied.
This research presents a new algorithm for classification the
shadow and water bodies for high-resolution satellite images (4-
meter) of Baghdad city, have been modulated the equations of the
color space components C1-C2-C3. Have been using the color space
component C3 (blue) for discriminating the shadow, and has been
used C1 (red) to detect the water bodies (river). The new technique
was successfully tested on many images of the Google earth and
Ikonos. Experimental results show that this algorithm effective to
detect all the types of the shadows with color, and also detects the
water bodies in another color. The benefit of this new technique to
discriminate between the shadows and water in fast Matlab pro
The study presents the test results of Completely Decomposed Granite (CDG) soil tested under drained triaxial compression, direct shear and simple shear tests. Special attention was focused on the modification of the upper halve of conventional Direct Shear Test (DST) to behave as free
head in movement along with vertical strain control during shear stage by using Geotechnical Digital System (GDS). The results show that Free Direct Shear Test (FDST) has clear effect on the measured shear stress and vertical strain during the test. It has been found that shear strength
parameters measured from FDST were closer to those measured from simple shear and drained triaxial compression test. This study also provides an independent check on