Preferred Language
Articles
/
jkmc-33
Role of MRI diffusion weighted imaging in differentiation between benign and malignant ovarian masses
...Show More Authors

Background: Characterization of the ovarian masses preoperatively is important to inform the surgeon about the possible management strategies. MRI may be of great help in identifying malignant lesion before surgery. Diffusion Weighted Imaging (DWI) is a sensitive method for changes in proton of water mobility caused by pathological alteration of tissue cellularity, cellular membrane integrity, extracellular space perfusion, and fluid viscosity.

Objective: to study the diagnostic accuracy of DWI in differentiation between benign and malignant ovarian masses.

Type of the study:Cross-sectional study.

Methods: this study included  53with complex ovarian mass or masses ,Diffusion Weighted Imaging was obtained to all these patient with correlation to the histopathological results; the Signal Intensity (SI) of the solid and cystic part of the lesions was evaluated on T2 and Diffusion Weighted Imaging  ,with Apparent Diffusion Coefficient (ADC) values were also obtained .

Results: 22 masses out of the total 53 were malignant and 31 were benign .On DWI the high SI intensity observed more frequently in the malignant lesions than the benign lesions (p value 0.0293) .There was significant difference between the mean ADC value of the malignant and benign ovarian lesions, with the mean ADC value for the benign lesions solid component =1.05 x10 -3, and the mean ADC value for the malignant lesions solid component =0.91 x10-3. The ROC study reveals that 0.926 x 10 -3  may be the optimal cutoff value  with sensitivity 54.8 %, specificity 59.1%, NPV 48.15 %, PPV 63.39%  , Accuracy 56.6%. With exclusion of the teratoma and endometriomas from statistical analysis the ROC reveals that 0.99 x10 -3  may be the optimal cut off value with sensitivity 76.9 % , specificity 77.3% , PPV 66.67% , NPP 85% and  accuracy 77.14% Conclusions: Combined with conventional pelvic MRI, DWI is a helpful tool in differentiation between benign and malignant ovarian masses, with high signal intensity on DWI more frequently observed in the malignant than benign ovarian lesions.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
دراسات دولية
Importance of Promoting the Study of Scientific Research Methodology in Political Science
...Show More Authors

There are main methods of scientific research, and that the researcher's choice of the appropriate methodology for scientific research is one of the most important rules on which the researcher must rely in order to prepare scientific research properly. There is no doubt that the methodology of scientific research is of great importance that they all agree on the preparation of accurate scientific research. Scientific research is an organized research that does not come by chance, but comes as a result of the activity of the mind. It is theoretical because it relies on theories for the purposes of perceiving the proportions and relationships between things, and everyone is subjected to testing and experiment.

Publication Date
Sun Mar 31 2024
Journal Name
Iraqi Geological Journal
Determination of Reservoir Rock Type in Sarvak Reservoir of an Iranian Oilfield
...Show More Authors

Integrated reservoir rock typing in carbonate reservoirs is a significant step in reservoir modelling. The key purpose of this study is the identification of integrated rock types in the Sarvak Formation of an Iranian oilfield. In this study, electrofacies (EFAC) analysis of the Sarvak reservoir was done in detail to determine the reservoir quality and rock types of the Sarvak Formation in the studied field. The core data and conventional petrophysical logs were used for rock typing. Some petrophysical logs such as porosity, sonic, neutron, density, and Photo electric factor were applied as input data for electrofacies analysis. Multi-Resolution Graph-Based Clustering was used among six approaches, resulting in four electrofacies af

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Evaluation of D-Dimer in the diagnosis of suspected deep vein thrombosis
...Show More Authors

Background: Deep vein thrombosis is a multi causal disease and its one of most common venous disorder, but only one quarter of the patients who have signs and symptoms of a clot in the vein actually have thrombosis and need treatment .The disease can be difficult to diagnose. Venous ultrasound in combination with clinical finding is accurate for venous thromboembolism, its costly because a large number of patients with suspicious signs and symptoms. Venography still the gold standard for venous thromboembolism but it is invasive. The D-dimer increasingly is being seen as valuable tool rolling out venous thromboembolism and sparing low risk patients for further workup.Objectives: this study has designed the role of D-dimer to confirm diag

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 16 2016
Journal Name
World Journal Of Pharmaceutical Research
Identification of some species of wireworm Agriotes spp.(Coleoptera: Elateridae) in Baghdad
...Show More Authors

Publication Date
Sat Jan 02 2021
Journal Name
International Journal Of Pharmaceutical Research
Detection of Kaposi’s Associated Herpesvirus in Saliva of Drug Related Immunosupressed Patient
...Show More Authors

View Publication
Crossref
Publication Date
Thu May 03 2001
Journal Name
Master's Thesis
The image of the United States of America in the Iraqi press
...Show More Authors

Preview PDF
Publication Date
Wed Sep 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Enhancement of Uniformity of Solid Particles in Spouted Bed Using Stochastic Optimization
...Show More Authors

Performance of gas-solid spouted bed benefit from solids uniformity structure (UI).Therefore, the focus of this work is to maximize UI across the bed based on process variables. Hence, UI is to be considered as the objective of the optimization process .Three selected process variables are affecting the objective function. These decision variables are: gas velocity, particle density and particle diameter. Steady-state solids concentration measurements were carried out in a narrow 3-inch cylindrical spouted bed made of Plexiglas that used 60° conical shape base. Radial concentration of particles (glass and steel beads) at various bed heights and different flow patterns were measured using sophisticated optical probes. Stochastic Genetic

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Effect of pesticide Glyphosate Aqua in liver enzymes activity of Barbus sharpeyi
...Show More Authors

The present study was designed in the aquaculture and fish nutrition research aquarium in the College of Veterinary Medicine/Baghdad University from a period 1/3 to 1/6/2013 to investigate the toxicity of the herbicide glyphosate aqua on Barbus sharpeyi fish. Fish fingerlings were used with average weight between 10 – 15 gm to measure the (LC50), and 200 fingerlings were used to know the acute and chronic toxic effect for the herbicide. The fingerlings were randomly distributed as 10 fish for each aquarium. Fish were divided into four treatments and control group (without addition of herbicide). The first processing with a concentration of 0.415 mg/L for a duration of exposure 90 days, the second processing group with a concentration 0.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
The Efficacy of (810 Nm) Diode Laser in Treatment of Idiopathic Epistaxis
...Show More Authors

There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one

... Show More
View Publication Preview PDF