Preferred Language
Articles
/
jkmc-33
Role of MRI diffusion weighted imaging in differentiation between benign and malignant ovarian masses

Background: Characterization of the ovarian masses preoperatively is important to inform the surgeon about the possible management strategies. MRI may be of great help in identifying malignant lesion before surgery. Diffusion Weighted Imaging (DWI) is a sensitive method for changes in proton of water mobility caused by pathological alteration of tissue cellularity, cellular membrane integrity, extracellular space perfusion, and fluid viscosity.

Objective: to study the diagnostic accuracy of DWI in differentiation between benign and malignant ovarian masses.

Type of the study:Cross-sectional study.

Methods: this study included  53with complex ovarian mass or masses ,Diffusion Weighted Imaging was obtained to all these patient with correlation to the histopathological results; the Signal Intensity (SI) of the solid and cystic part of the lesions was evaluated on T2 and Diffusion Weighted Imaging  ,with Apparent Diffusion Coefficient (ADC) values were also obtained .

Results: 22 masses out of the total 53 were malignant and 31 were benign .On DWI the high SI intensity observed more frequently in the malignant lesions than the benign lesions (p value 0.0293) .There was significant difference between the mean ADC value of the malignant and benign ovarian lesions, with the mean ADC value for the benign lesions solid component =1.05 x10 -3, and the mean ADC value for the malignant lesions solid component =0.91 x10-3. The ROC study reveals that 0.926 x 10 -3  may be the optimal cutoff value  with sensitivity 54.8 %, specificity 59.1%, NPV 48.15 %, PPV 63.39%  , Accuracy 56.6%. With exclusion of the teratoma and endometriomas from statistical analysis the ROC reveals that 0.99 x10 -3  may be the optimal cut off value with sensitivity 76.9 % , specificity 77.3% , PPV 66.67% , NPP 85% and  accuracy 77.14% Conclusions: Combined with conventional pelvic MRI, DWI is a helpful tool in differentiation between benign and malignant ovarian masses, with high signal intensity on DWI more frequently observed in the malignant than benign ovarian lesions.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 28 2019
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Value of Combination of Standard Axial and Thin-Section Coronal Diffusion-weighted Imaging in Diagnosis of Acute Brainstem Infarction

AIM: To determine the value of the combination of thin-section 3 mm ‎coronal and standard ‎axial DWI and their impact in facilitating the diagnosis of ‎‎acute brainstem infarction. METHODS: A cross-sectional study conducted from the 1st of April 2017 to the end of February 2018 on 100 consecutive patients (66% were male, and 34% were female) with isolated acute ischemic infarction in the ‎brainstem. The abnormal MRI findings concerning the ischemic lesions were interpreted on standard axial 5 mm and thin-section coronal 3mm DWI. RESULTS: The mean age of the studied group was 69.2 ± 4.3 for male and 72.3 ± 2.5 years. The standard axial DWI can diagnose 20%, 6.7% and 6.7% of the infarctions in midbrain, pons an

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Binding studies of lh in benign and malignant uterine tumors

the sera levels of luteninizing hormone were investgaited prior tq surgery in 10 postmenopaisal women with benign and 10 postmenopausal women with maliganant healthy

View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Most appropriate conditions of the binding of LH in Benign and Malignant

Test method was developed radioimmunotherapy to appoint in two groups of patients infected with a uterine tumor Great conditions in tumor tissue benign and malignant Ddh teacher radioactive iodine isotope

View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
the kincetic studies of lh binding in benign an malignant uterine

kinetic studies were carried out the uterine homogenate time course of the association of with LH in benign and malignant uterine

View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Clinical Evaluation of the Levels of CEA,CA15-3 and AlphaFeto Protein in Malignant and Benign Pleural Effusion

Background: Pleural effusion is a common clinical
problem.
Objective: The aim of the study was to evaluate the
diagnostic utility of Carcino embryonic antigen
(CEA), CA 15- 3, and alpha-feto protein ( AFP ) as
a tumor markers in serum and pleural effusion and
evaluate the value of combining them as a diagnostic
tools that are complementary to cytology in the
diagnosis of malignancies .
Methods: Forty patients (18 malignant and 22 benign
pleural effusion) were included in this study .The
serum and effusion levels of CEA, CA 15 – 3 and
AFP were measured using immunoradiometric assay
Results: from the 40 effusions studied 26 were
exudates and 14 were transudates. The level of
pleural effusions

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 30 2021
Journal Name
Al-kindy College Medical Journal
The Role of MRI-US Fusion Techniques in Detection of Clinically Significant Prostate Cancer

Prostate cancer is the commonest male cancer and the second leading cause of cancer-related death in men. Over many decades, prostate cancer detection represented a continuous challenge to urologists. Although all urologists and pathologists agree that tissue diagnosis is essential especially before commencing active surgical or radiation treatment, the best way to obtain the biopsy was always the big hurdle. The heterogenicity of the tumor pathology is very well seen in its radiological appearance. Ultrasound has been proven to be of limited sensitivity and specificity in detecting prostate cancer. However, it was the only available targeting technique for years and was used to guide biopsy needle passed transrectally or transperineally

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Advances In Computing
A New Abnormality Detection Approach for T1-Weighted Magnetic Resonance Imaging Brain Slices Using Three Planes

Generally, radiologists analyse the Magnetic Resonance Imaging (MRI) by visual inspection to detect and identify the presence of tumour or abnormal tissue in brain MR images. The huge number of such MR images makes this visual interpretation process, not only laborious and expensive but often erroneous. Furthermore, the human eye and brain sensitivity to elucidate such images gets reduced with the increase of number of cases, especially when only some slices contain information of the affected area. Therefore, an automated system for the analysis and classification of MR images is mandatory. In this paper, we propose a new method for abnormality detection from T1-Weighted MRI of human head scans using three planes, including axial plane, co

... Show More
Publication Date
Thu Sep 19 2024
Journal Name
Irish Journal Of Medical Science (1971 -)
Correlation between clinical and MRI findings in disc herniation in the lumbosacral region

View Publication
Scopus Clarivate Crossref
Publication Date
Thu Jul 21 2022
Journal Name
Neuro Quantology
Astronomical Observation between Diffraction Limited Coherent and Incoherent Imaging Systems

Numerical simulations are carried out to evaluate the coherence concept’s effect on the performance regarding the optical system, when observing and imaging the planet’s surface. In numerous optical approaches, the coherence qualities of light sources play an important role. This paper provides an overview about the mathematical formulation of temporal and spatial coherence and incoherence properties of light sources. The circular aperture was used to describe the optical system like a telescope. The simulation results show that diffraction-limited for incoherent imaging system certainly improves the image. Yet, the quality of the image is degraded by the light source's highly spatial and temporal coherence properties, resulting in a

... Show More
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Comparison between Modified Weighted Pareto Distribution and Many other Distributions

 

In 2020 one of the researchers in this paper, in his first research, tried to find out the Modified Weighted Pareto Distribution of Type I by using the Azzalini method for weighted distributions, which contain three parameters, two of them for scale while the third for shape.This research compared the distribution with two other distributions from the same family; the Standard Pareto Distribution of Type I and the Generalized Pareto Distribution by using the Maximum likelihood estimator which was derived by the researchers for Modified Weighted Pareto Distribution of Type I, then the Mont Carlo method was used–that is one of the simulation manners for generating random samples data in different sizes ( n= 10,30,50), and in di

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref