Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture in children. Type of the study: A prospective study. Methods: During the period between February/2012 and May/2015, we made a prospective study of (18) patients suffered from O′Brien type II&III radial neck fracture with severe angulation that require surgery seen at Al-Kindy Teaching Hospitals. However, we select a group of children who had more than 30° of Radial head angulation really cannot treated by conservative method. Angulated radial neck fractures in children reduced with a percutaneous Kirschner wire. We select of surgical procedure after failure of thumbing intraoperatively. The primary indication for surgery was changing type II&III to typeI which can go on in manage conservatively. Results: All the (18) patients treated with percutaneous pinning techniques were followed-up, clinically and radiographically evaluated pre-surgery, post-surgery and finally (6) months after surgery. The mean angulation of the fractures was 64° (30° - 90°) before reduction and 10°(0° - 22°) after reduction. Mean fracture displacement after reduction in all cases was less than 3 mm. Range of Motion (ROM) in flexion, extension, pronation and supination was the functional parameter in our study as graded by (the grading system of Steele). We obtained an outcome of excellent results in 15 patient (83%), good results in 3 patients (17%) and we have no fair or poor results. Conclusions Percutaneous Joystick Reduction Techniqueusing K-wire in children with radial neck fractures is a safe, short, easy procedure requires only good technical measures, minimally invasive in nature with minimal hospitalization time, has a minimal morbidity and complication rates, it is recommended surgical treatment that can achieve recovery of normal radial neck angulation, elbow motion and yielding excellent results.
Objective: To assess prospectively functional outcome of interlocked intramedullary nailing fixation in management of closed tibia shaft fractures. Methodology: This prospective study included 134 patients with closed shaft tibia fractures with age 18-60 years and isolated closed fracture of shaft of tibia. The fractures were fixed by interlocking intramedullary nail. At follow-up after 12 months postoperatively, the functional outcome was assessed radiographically for the sign of union and clinically according to Klemm-Borner criteria. Results: The mean age was 38.55 years. Out of 134 patients, 55.2% were male. The cause was road traffic accident in 44.8%, majority of the fracture occur in the mid-shaft (41.8%), and oblique fracture was th
... Show MoreTwo locally isolated microalgae (Chlorella vulgaris Bejerinck and Nitzschia palea (Kützing) W. Smith) were used in the current study to test their ability to production biodiesel through stimulated in different nitrogen concentration treatments (0, 2, 4, 8 gl ), and effect of nitrogen concentration on the quantity of primary product (carbohydrate, protein ), also the quantity and quality of lipid. The results revealed that starvation of nitrogen led to high lipid yielding, in C. vulgaris and N. palea the lipid content increased from 6.6% to 40% and 40% to 60% of dry weight (DW) respectively.Also in C. vulgaris, the highest carbohydrate was 23% of DW from zero nitrate medium and the highest protein was 50% of DW in the treatment 8gl. Whil
... Show MoreThe current research dealt with the study of space compatibility and its role in enhancing the functional aspect of the design of the interior spaces of isolation hospitals by finding a system or format that is compatible with the nature of the changes occurring in the structure and function of the space system, as well as contributing to enhancing compatibility between the functional aspect and the interior space. Therefore, the designer must The interior is the study of the functional and spatial aspects as they are the basic aspects for achieving suitability, and through the interaction between the person and the place, the utilitarian performance characteristics are generated that the interior designer is interested in and tries to d
... Show MoreEvaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars, Hussain A Taher*, Salwan Y Bede
Catalytic reduction is considered an effective approach for the reduction of toxic organic pollutants from the environment, but finding an active catalyst is still a big challenge. Herein, Ag decorated CeO2 catalyst was synthesized through polyol reduction method and applied for catalytic reduction (conversion) of 4-nitrophenol (4-NP) to 4-aminophenol (4-AP). The Ag decorated CeO2 catalyst displayed an outstanding reduction activity with 99% conversion of 4-NP in 5 min with a 0.61 min−1 reaction rate (k). A number of structural characterization techniques were executed to investigate the influence of Ag on CeO2 and its effect on the catalytic conversion of 4-NP. The outstanding catalytic performances of the Ag-CeO2 catalyst can be assigne
... Show MoreABSTRACT Background: resin cement type and intraoral temperature fluctuations may affect the fracture performance of successful zirconia restorations. To fill this gap, the purpose of this study is to evaluate and compare the influence of thermocycling on fracture resistance and mode of failure of monolithic zirconia crowns luted with Rely X™ U200 and BreezeTMself-adhesive resin cements as well as imply the effect of adding 2 % of polylysine (PLS) to these cements. Materials: 64 maxillary premolars were milled out of zirconia blocks using CAD/CAM milling system. They were divided into four groups (n = 16) according to the cement type. Four different resin cements were used (RelyXTMU200, Breeze™, RelyX™ U200 with 2 % PLS
... Show MoreElbow stiffness is hard to treat and commonly resulted from trauma or degenerative arthritis. This study aimed to demonstrate the effectiveness of using ultrasound therapy in management of stiff elbow joint resulted from several etiological factors. A total number of 42 patients (35 male and 7 female) allocated randomly from the Department of Physiotherapy at Al-yarmouk Teaching Hospital during 2013. Each patient examined physically by physiotherapist taking in consideration the measurement of the joint movement angle using goniometer in flexion and the extension, and the pain score using visual analogue scale (VAS). Ultrasound therapy initiated thrice weekly for two weeks. At the time of entry, the means degree of flexion and extension
... Show More