Preferred Language
Articles
/
jkmc-185
Association of Echocardiographic Epicardial Fat Thickness and Carotid Intima Media Thickness with the Severity of Coronary Artery Disease
...Show More Authors

Background: Coronary artery disease remains the main cause of death despite several preventive programs. Epicardial adipose tissue is a visceral fat depot of the heart located along the large coronary arteries and on the surface of ventricles and apex. Intima media thickness is commonly recognized as the initial stage in the development of atherosclerosis. The development of ultrasound machines, advances in echocardiographic devices and high resolution transducers facilitate comprehensive analysis of epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT).
Aim: To investigate the relationship of echocardiographic epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT) with the severity of coronary artery disease.
Methods: A cross sectional multicenter diagnostic accuracy study carried out at Ibn Al-Nafis Cardiovascular Hospital, Ibn Al- Bitar Cardiology Center and Ghazi Al-Hariri Hospital –Iraqi Center for Cardiology during the period between October 2016 and May 2017 assessing. History regarding demographic data and risk factors was taken. Two dimensional transthoracic echocardiographic measurements were done. EFT was measured from parasternal long axis view perpendicular to the right ventricular free wall. C-IMT was measured according to that recommended by the American society of echocardiography (ASE).
Results: The current study demonstrated that the EFT has a direct and significant correlation with the number of involved vessels (P value ˂ 0.001, r= 0.770). The validity of EFT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.984, cut point > 8mm, sensitivity=92.9%, specificity= 93.3%). There is inverse and significant correlation between ejection fraction (EF) and three vessels disease (P value ˂ 0.001, r= -0.507). Also there is a direct and significant correlation between C-IMT and severity of CAD. ROC analysis for validity of C-IMT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.961, cut point > 1.04mm, sensitivity=92.9%. specificity=86.7%). C-IMT is fair to discriminate between single vessel disease and no vessel involvement (AUC=0.738, cut point ˃ 0.84mm, sensitivity 100%), so if correlated with age, C-IMT above 0.84 can be used as a cut off point for the prediction of CAD. Finally, EFT and C-IMT are more likely to reflect severity of CAD than their ratio.
Conclusions: C-IMT and EFT are simple and reproducible parameters that can be used as a screening tool for the presence and severity of CAD especially before symptoms appearance in high risk patients

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Fat Mass and Obesity Association gene Polymorphism in PCOS Iraqi Women
...Show More Authors

             Polycystic syndrome (PCOS) is a considerable infertility disorder in adolescents and adult women in reproductive age. Obesity is a vigorous risk factor related to POCS.  This study aims to evaluate the association of obesity and PCOS by investigating several parameters including:  anthropological, biochemical (lipid profile, fasting blood sugar, glucose tolerance test, and hormone levels (LH, FSH, LH/FSH ratio, Estradiol2 and Testosterone),and genetic parameters (Fat mass and Obesity associated gene (FTO) polymorphism at rs17817449) in 63 obese and non-obese PCOS women. The biochemical tests were investigated by colorimetric methods while FTO gene polymorp

... Show More
View Publication Preview PDF
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Fat Mass and Obesity Association gene Polymorphism in PCOS Iraqi Women
...Show More Authors

             Polycystic syndrome (PCOS) is a considerable infertility disorder in adolescents and adult women in reproductive age. Obesity is a vigorous risk factor related to POCS.  This study aims to evaluate the association of obesity and PCOS by investigating several parameters including:  anthropological, biochemical (lipid profile, fasting blood sugar, glucose tolerance test, and hormone levels (LH, FSH, LH/FSH ratio, Estradiol2 and Testosterone),and genetic parameters (Fat mass and Obesity associated gene (FTO) polymorphism at rs17817449) in 63 obese and non-obese PCOS women. The biochemical tests were investigated by colorimetric methods while FTO gene polymorphism was detected by PCR–RFLP.  Lipid profile, F

... Show More
Preview PDF
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study the Effect of Thickness on the Electrical Conductivity and Optical Constant of Co3O4 Thin Films
...Show More Authors

 In this research the Cobalt Oxide (Co3O4) films are prepared by the method of chemical spray pyrolysis deposition at different thicknesses such that (250, 350, 450, and 550) ± 20 nm.      The optical measurement shows that the Co3O4 films have a direct energy gap, and they in general increase with the increase of the thickness. The optical constants are investigated and calculated such as absorption coefficient, refractive index, extinction coefficient and the dielectric constants for the wavelengths in the range (300-900) nm.     The electrical conductivity (σ) and the activation energies (Ea1, Ea2) have been investigated on (Co3O4) thin films as a function of thickness. The films

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Study the effect of thickness and annealing temperature on the Electrical Properties of CdTe thin Films
...Show More Authors

The electrical properties of polycrystalline cadmium telluride thin films of different thickness (200,300,400)nm deposited by thermal evaporation onto glass substrates at room temperature and treated at different annealing temperature (373, 423, 473) K are reported. Conductivity measurements have been showed that the conductivity increases from 5.69X10-5 to 0.0011, 0.0001 (?.cm)-1 when the film thickness and annealing temperature increase respectively. This increasing in ?d.c due to increasing the carrier concentration which result from the excess free Te in these films.

View Publication Preview PDF
Crossref
Publication Date
Sat Oct 30 2021
Journal Name
Iraqi Journal Of Science
Estimation of Hematological Parameters of Disease Severity in Iraqi Patients with COVID-19
...Show More Authors

    Coronavirus disease 2019 (COVID-19) is a systemic disease with a substantial impact on the hematopoietic system and hemostasis. Neutrophilia is an early indicator of SARS-CoV-2 infection, while lymphopenia acts as a biomarker of the severity of infection, and the neutrophil-to-lymphocyte ratio (NLR) is the main indicator of cytokine storms. Thus, this study aimed to provide local data about hematological parameters among COVID-19 patients and estimate their correlation with viral load and other factors in severe cases. A total of 99 nasopharyngeal swabs and whole blood specimens were collected from individuals suspected with COVID-19 between October and December 2020. Samples were tested by real time reverse transcript

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (3)
Scopus Crossref
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effects of Hypothermia on Renal Functions for Patients undergo Coronary Artery Bypass Graft Surgery
...Show More Authors

Objective: To determine the effectiveness of hypothermia on renal functions for patients undergoing
coronary artery bypass graft CABG surgery.
Methodology: A purposive (non-probability) sample of (50) patients undergoing Isolated coronary artery
bypass graft surgery consecutively admitted to the surgical ward, and they were followed up in the
intraoperative, Intensive Care Unit (ICU) and in the postoperative (surgical ward). Post-operative renal function
test (glumeruler filteration rate (GFR) by using the Crockroft-Gault formula and serum creatinine level) was
determined first week post operative and post operative renal function was classified on the base of peak of
the serum creatinine level and decline of glomeru

... Show More
View Publication Preview PDF
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Effect of thickness on structural properties of BixSb2-xTe3 thin films
...Show More Authors

BixSb2-xTe3 alloys with different ratios of Bi (x=0, 0.1, 0.3, 0.5, and 2) have been prepared, Thin films of these alloys were prepared using thermal evaporation method under vacuum of 10-5 Torr on glass substrates at room temperature with different deposition rate (0.16, 0.5, 0.83) nm/sec for thickness (100, 300, 500) respectively. The X–ray diffraction measurements for BixSb2-xTe3 bulk and thin films indicate the polycrystalline structure with a strong intensity of peak of plane (015) preferred orientation with additional peaks, (0015) and (1010 ) reflections planes, which is meaning that all films present a very good texture along the (015) plane axis at different intensities for each thin film for different thickness. AFM measureme

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Apr 13 2021
Journal Name
Latin American Journal Of Pharmacy
The Experience with Hospitalized COVID-19 Patients in Al-Basra, Iraq: Predictors of the disease severity
...Show More Authors

SUMMARY. The objectives of the present study were to assess the possible predictors of COVID-19 severity and duration of hospitalization and to identify the possible correlation between patient parameters, disease severity and duration of hospitalization. The study included retrospective medical record extraction of previous coron avirus COVID-19 patients in Basra hospitals, Iraq from March 1st and May 31st, 2020. The information of the participants was investigated anonymously. All the patients’ characteristics, treatments, vital signs and laboratory tests (hematological, renal and liver function tests) were collected. The analysis was conducted using the SPSS (version 22, USA). Spearman correlation was used to measure the relations

... Show More
Scopus
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
ESTIMATION OF THE OPTIMUM BED THICKNESS OF A FLOWTHROUGH POROUS ELECTRODE (FTPE) WORKING UNDER MASS TRANSFER CONTROL
...Show More Authors

In this paper, a theoretical analysis of optimum bed thickness operates under mass transfer control for realizing a high efficiency and reaction conversion of an electrochemical reactor has been made based on flowthrough porous electrode (FTPE) configuration. Many models have been used to represent the optimum bed thickness by taking a look into previous works concerned and collecting all related information, data, and models. The parameters that affect the optimum bed thickness have been visualized and reviewed, and almost all of them have been examined by experimental data from different sources and based on the various models. It has been found that the increase in electrolyte flow rate, concentration, limiting current density, and sp

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jan 06 2018
Journal Name
American Institute Of Physics
Synthesis and characterization study of n-Bi2O3/p-Si heterojunction dependence on thickness
...Show More Authors

Abstract. In this work, Bi2O3 was deposited as a thin film of different thickness (400, 500, and 600 ±20 nm) by using thermal oxidation at 573 K with ambient oxygen of evaporated bismuth (Bi) thin films in a vacuum on glass substrate and on Si wafer to produce n-Bi2O3/p-Si heterojunction. The effect of thickness on the structural, electrical, surface and optical properties of Bi2O3 thin films was studied. XRD analysis reveals that all the as deposited Bi2O3 films show polycrystalline tetragonal structure, with preferential orientation in the (201) direction, without any change in structure due to increase of film thickness. AFM and SEM images are used to investigate the influences of film thickness on surface properties. The optical measur

... Show More
Preview PDF