Background: Coronary artery disease remains the main cause of death despite several preventive programs. Epicardial adipose tissue is a visceral fat depot of the heart located along the large coronary arteries and on the surface of ventricles and apex. Intima media thickness is commonly recognized as the initial stage in the development of atherosclerosis. The development of ultrasound machines, advances in echocardiographic devices and high resolution transducers facilitate comprehensive analysis of epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT).
Aim: To investigate the relationship of echocardiographic epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT) with the severity of coronary artery disease.
Methods: A cross sectional multicenter diagnostic accuracy study carried out at Ibn Al-Nafis Cardiovascular Hospital, Ibn Al- Bitar Cardiology Center and Ghazi Al-Hariri Hospital –Iraqi Center for Cardiology during the period between October 2016 and May 2017 assessing. History regarding demographic data and risk factors was taken. Two dimensional transthoracic echocardiographic measurements were done. EFT was measured from parasternal long axis view perpendicular to the right ventricular free wall. C-IMT was measured according to that recommended by the American society of echocardiography (ASE).
Results: The current study demonstrated that the EFT has a direct and significant correlation with the number of involved vessels (P value ˂ 0.001, r= 0.770). The validity of EFT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.984, cut point > 8mm, sensitivity=92.9%, specificity= 93.3%). There is inverse and significant correlation between ejection fraction (EF) and three vessels disease (P value ˂ 0.001, r= -0.507). Also there is a direct and significant correlation between C-IMT and severity of CAD. ROC analysis for validity of C-IMT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.961, cut point > 1.04mm, sensitivity=92.9%. specificity=86.7%). C-IMT is fair to discriminate between single vessel disease and no vessel involvement (AUC=0.738, cut point ˃ 0.84mm, sensitivity 100%), so if correlated with age, C-IMT above 0.84 can be used as a cut off point for the prediction of CAD. Finally, EFT and C-IMT are more likely to reflect severity of CAD than their ratio.
Conclusions: C-IMT and EFT are simple and reproducible parameters that can be used as a screening tool for the presence and severity of CAD especially before symptoms appearance in high risk patients
Background: Masseter muscle is one of the most obvious muscles of mastication and considered as one indicator of jaw muscle activity. It has a major influence on the transverse growth of the midface and the vertical growth of the mandible. This study undertaken to determine the role of cephalometric analysis for discrimination between Cl I and Cl III skeletal relationships, determine the role of ultrasonography in determination of masseter muscle thickness, compare masseter muscle thickness between Cl I and Cl III skeletal relationships, and determine the effect of gender on masseter muscle thickness. Material and Method: The sample of the current study consisted of 70 Iraqi subjects 40 males and 30 females with age ranging 18-25 years. The
... Show MoreZinc Oxide (ZnO) thin films of different thickness were prepared
on ultrasonically cleaned corning glass substrate, by pulsed laser
deposition technique (PLD) at room temperature. Since most
application of ZnO thin film are certainly related to its optical
properties, so the optical properties of ZnO thin film in the
wavelength range (300-1100) nm were studied, it was observed that
all ZnO films have high transmittance (˃ 80 %) in the wavelength
region (400-1100) nm and it increase as the film thickness increase,
using the optical transmittance to calculate optical energy gap (Eg
opt)
show that (Eg
opt) of a direct allowed transition and its value nearly
constant (~ 3.2 eV) for all film thickness (150
Polycrystalline Cadmium Oxide (CdO) thin films were prepared using pulsed laser deposition onto glass substrates at room temperature with different thicknesses of (300, 350 and 400)nm, these films were irradiated with cesium-137(Cs-137) radiation. The thickness and irradiation effects on structural and optical properties were studied. It is observed by XRD results that films are polycrystalline before and after irradiation, with cubic structure and show preferential growth along (111) and (200) directions. The crystallite sizes increases with increasing of thickness, and decreases with gamma radiation, which are found to be within the range (23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for thickness 350nm and 4
... Show MorePolycrystalline Cadmium Oxide (CdO) thin films were prepared
using pulsed laser deposition onto glass substrates at room
temperature with different thicknesses of (300, 350 and 400)nm,
these films were irradiated with cesium-137(Cs-137) radiation. The
thickness and irradiation effects on structural and optical properties
were studied. It is observed by XRD results that films are
polycrystalline before and after irradiation, with cubic structure and
show preferential growth along (111) and (200) directions. The
crystallite sizes increases with increasing of thickness, and decreases
with gamma radiation, which are found to be within the range
(23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for
Introduction Periodontal diseases are ranked among the most common health problems affecting mankind. These conditions are initiated by bacterial biofilm, which is further modulated by several risk factors. Objectives To investigate the association of different risk factors with periodontal...
A study of the effects of the discharge (sputtering) currents (60-75 mA) and the thickness of copper target (0.037, 0.055 and 0.085 mm) on the prepared samples was performed. These samples were deposited with pure copper on a glass substrate using dc magnetron sputtering with a magnetic flux density of 150 gauss at the center. The effects of these two parameters were studied on the height, diameter, and size of the deposition copper grains as well as the roughness of surface samples using atomic force microscopy (AFM).The results of this study showed that it is possible to control the specifications of copper grains by changing the discharge currents and the thickness of the target material. The increase in discharge curre
... Show MoreBackground: Helicobacter pylori are important gastrointestinal pathogen associated with gastritis, peptic ulcers, and an increased risk of gastric carcinoma. There are several popular methods for detection of H. pylori (invasive and non-invasive methods) each having its own advantages, disadvantages, and limitations, and by using PCR technique the ability to detect H. pylori in saliva samples offers a potential for an alternative test for detection of this microorganism. Materials and methods: The study sample consists of fifty participants of both genders, who undergo Oesophageo-gastrodudenoscopy at the Gastroenterology Department of Al-Kindy Teaching Hospital Baghdad/ Iraq, during five months period from January 2014 to May 2014. They we
... Show MoreThis study aimed new indications that may clarify the relationships between the total and standard lengths, and the length of the otolith, as well as the thickness and weight of these bones compared to the body weights of two different species of invasive fish in the Iraqi aquatic environment, the common carp