Preferred Language
Articles
/
jkmc-129
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer lens Implantat for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.

Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in  Eye Specialty Private Hospital, Baghdad, Iraq.

Type of the Study: a prospective non randomize intervention study.

Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter (D) ±3.17 (SD) with range from ₋6.00 to ₋18.00D and the mean cylinder was -2.61(D) ±1.16 with range from ₋1.00 to ₋5.50D .The outcome measures that evaluated during a 12 months follow-up period include UDVA, refractive outcomes, CDVA, vault and adverse events.

Results: At 12 months postoperatively the mean Snellen decimal UDVA was 0.77±0.23 and mean CDVA was 0.80±0.21, with an efficacy index 1.16. Twenty nine  eyes (48.33%) showed gain in CDVA with safety index

 

 

1.21.The treatment was highly predictable for spherical equivalent and astigmatic component .The mean SE dropped from (₋12.63D ±3.11) to ( ₋0.11 D±0.20) with 58 eyes within ±0.50 D and 60 eyes with ± 1.00D of target correction . For achieved cylinder 60 eyes (100%) had ≤0.50D and 51 eyes (85%) had ≤0.25D with strong positive linear correlation between achieved and expected cylinder(r=0.94)

Conclusions: The results of the present study support safety, efficacy, predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Magnetic Lens Design Using Analytical Target Field Function
...Show More Authors

Analytical field target function has been considered to represent the axial magnetic field distribution of double polepiece symmetric magnetic lens. In this article, with aid of the proposed target function, the syntheses procedure is dependent. The effect of the main two coffectin optimization parameters on the lens field distribution, polepieces shape, and the objective focal prosperities for lenses operated under zero magnification mode has been studied. The results have shown that the objective properties evaluated in sense of the inverse design procedure are in an excellent correspondence with that of analysis approach. Where the optical properties enhance as the field distribution of the electron lens distributed along a narrow axi

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Design of Electrostatic Unipotential Lens Accelerating And Decelerating Operated Under Finite And Infinite Magnification Conditions
...Show More Authors

  Theoretical study computerized has been carried out in field electron optics , to design electrostatic unipotential lens , the inverse problem is important method in the design of electrostatic lenses by suggesting an axial electrostatic potential distribution using polynomial function. The paraxial –ray equation is solved to obtain the trajectory particles that satisfy the suggested potential function. In this research , design electrostatic unipotential lens three-electrode accelerating and decelerating L=5 mm operated under finite and infinite magnification conditions. The electrode shape of the electrostatic lens was then determined from the solution of the Laplace's equation's. the results showed low values of spherica

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 03 2023
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
The Effectiveness of Autogenous Dentin Graft as a Biomaterial in Optimizing the Esthetic Outcomes of Immediate Dental Implants: A Prospective Clinical Study
...Show More Authors

Background: Immediate implant placement in the maxillary anterior region was challenging, especially with the jumping gap and limited primary implant stability. Objective: To assess the autogenous dentin graft biomaterial's ability to improve the esthetic outcomes of an immediately inserted implant. Methods: Twenty patients with non-restorable retained roots in the maxillary non-molar region surrounded by natural sound teeth were included in this study after a complete clinical and radiological examination, including patient health and clinical fitness for the immediate dental implant procedure. A single dental implant was inserted for each patient, and the resulting jump distance was filled with the mineralized dentin graft and co

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Acta Facultatis Medicae Naissensis
A correlation between body mass index and refractive errors
...Show More Authors

Background. Body mass index (BMI) is a person's weight in kilograms (or pounds) divided by the square of height in meters (or feet). Obesity affects a wide spectrum of age groups, from the young to the elderly, and there are several eye diseases related to obesity like diabetic retinopathy, floppy eyelid syndrome, retinal vein occlusion, stroke-related vision loss, age-related macular degeneration, and possibly, refractive errors. Refractive errors (RE) are optical imperfections related to the focusing ability of the eye and are the main cause of visual impairment which may result in missed education and employment opportunities, lower productivity and impaired quality of life. Aim. The study aimed to find an association between bod

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Nov 08 2020
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Clinical course and disease outcomes in hospitalized patients with 2019 novel corona virus disease at Ibn- Al Khateeb Hospital in Baghdad, Iraq
...Show More Authors

Background: the novel coronavirus (2019-ncov), formally known as severe acute respiratory syndrome coronavirus 2 (sars-cov-2), the etiological cause of the (corona virus disease 2019) covid-19, appeared in wuhan, hubei province, china. On 11 march 2020, the world health organization (who) declared this disease as a pandemic. As new information on the clinical characteristics, treatment options, and outcomes for covid-19 emerges approximately every hour, physicians should keep themselves up-to-date on this topic.
Objective: to study the demographic features, clinical signs and symptoms and certain vital and laboratory findings of covid-19 hospitalized cases; and to identify the used medication, complications, length of stay at the hosp

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jul 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Simulation and Evaluation of a Variable Effective Focal Length of Refractive Binocular Telescope
...Show More Authors

The telescope works to magnify images of distant objects in general, but it needs special optical elements to complete the task to the fullest. The telescope needs optimal balance values of the optical parameters used to produce the best image, such as the effective focal length and the diameter of the pupil aperture, which are combined in a single concept called the focal number. The ground-based binary telescope relies on special lenses and an exceptional prism to achieve a hybrid design that produces clear images of relatively distant terrestrial objects. The pupil diameter of the telescope is relatively large to ensure that the largest possible amount of light is received, and as a result, a good image is obtained.

In this wo

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Design of Achromatic Combined Quadrupole Lens Using the Modified Bell-Shaped Field Distribution Model
...Show More Authors

The optimization calculations are made to find the optimum properties of combined quadrupole lens consist of electrostatic and magnetic lenses to produce achromatic lens. The modified bell-shaped model is used and the calculation is made by solving the equation of motion and finding the transfer matrices in convergence and divergence planes, these matrices are used to find the properties of lens as the magnification and aberrations coefficients. To find the optimum values of chromatic and spherical aberrations coefficients, the effect of both the excitation parameter of the lens (n) and the effective length of the lens into account as effective parameters in the optimization processing

View Publication Preview PDF
Publication Date
Sun Jul 24 2022
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The The predicting factors of clinical outcomes in patients with COVID-19 in the Kingdom of Saudi Arabia [KSA]: A multi-center cohort study
...Show More Authors

Background: On March 2020, the first case of coronavirus disease-19 was registered in the Kingdom of Saudi Arabia and subsequently the first mortality case. The predicting factors for patients' outcomes are essential to triage patients with COVID-19. This may provide low-cost facilities that help in the fight against the existing global pandemic.   

Objectives: This study aimed to predict hospitalization and death outcomes of COVID-19 patients using the simplest facilities.

Method: The electronic medical records of 280 COVID-19 patients between March 2020 and May 2021 were retrieved from a multi-centre of healthcare facilities across Kingdom of Saudi Arabian cites. All de

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 01 2016
Journal Name
Optics Communications
Temperature effect on nonlinear refractive indices of liquid crystals in visible and NIR
...Show More Authors

View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of the dimensions of the strategic lens on achieving tax pioneer performance: Practical research in the General Authority for Taxes
...Show More Authors

The aim of the research is to shed light on the dimensions of the strategic lens and its impact on achieving the pioneer tax performance and represented by the dimensions (strategic direction, growth, pilot indicator, renewal and modernization, efficiency and effectiveness) in the General Tax Authority. The questionnaire was adopted as a tool to collect data and information from the adult sample They are (91) who are on the site (Assistant Director General, Head of Division, First Division Deputy, Second Division Deputy, Division Officer, Division Officer Associate) The statistical program (SPSS) has been used to calculate (the mean, the standard deviation, the correlation coefficient, the difference coefficient, the F test, the

... Show More
View Publication Preview PDF