Preferred Language
Articles
/
jkmc-129
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer lens Implantat for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.

Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in  Eye Specialty Private Hospital, Baghdad, Iraq.

Type of the Study: a prospective non randomize intervention study.

Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter (D) ±3.17 (SD) with range from ₋6.00 to ₋18.00D and the mean cylinder was -2.61(D) ±1.16 with range from ₋1.00 to ₋5.50D .The outcome measures that evaluated during a 12 months follow-up period include UDVA, refractive outcomes, CDVA, vault and adverse events.

Results: At 12 months postoperatively the mean Snellen decimal UDVA was 0.77±0.23 and mean CDVA was 0.80±0.21, with an efficacy index 1.16. Twenty nine  eyes (48.33%) showed gain in CDVA with safety index

 

 

1.21.The treatment was highly predictable for spherical equivalent and astigmatic component .The mean SE dropped from (₋12.63D ±3.11) to ( ₋0.11 D±0.20) with 58 eyes within ±0.50 D and 60 eyes with ± 1.00D of target correction . For achieved cylinder 60 eyes (100%) had ≤0.50D and 51 eyes (85%) had ≤0.25D with strong positive linear correlation between achieved and expected cylinder(r=0.94)

Conclusions: The results of the present study support safety, efficacy, predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 03 2023
Journal Name
Karbala International Journal Of Modern Science
Performance Estimation and System Modeling for Refractive Index Structure Constant Cn2
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Thu Jul 17 2025
Journal Name
Journal Of Engineering
Correction Procedure for the Determination of Soil Specific Surface
...Show More Authors

View Publication
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
Generated and shifted of Ion beams By Electrostatic Lenses (Einzel lens)
...Show More Authors

In this paper, the path of the extracted and focused ions by the electrostatic lense having three electrodes of the same size and shape have been studied. However, the first and third electrodes had a different potential from the second electrode and the distance between any three electrodes was (d).The beams of the charged particles were controlled by using electrostatic fields which are used for accelerating and focusing. This paper focuses also on the effect of electrodes potentials on ion beam focusing. It is found that the best focusing was achieved when the values of the potential of the first and third electrode are equal to half of the value of the second electrode. Concerning transmiting and acumulating the ions beams, the study sh

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
The Datums Transformation for GPS Navigation Measurements Correction
...Show More Authors

The GPS navigation measurements become more widely used in many civilian and scientific application. All GPS navigation data holds many errors, the main error sources arise from the geodetic Datum variation when user apply the GPS measurements with the map. Geodetic datums define the size and shape of the earth and the origin and orientation of the coordinate systems used to map the earth surface. In this paper, the Datum transformation was evaluated in two mathematical methods to overcome the errors due to the difference between the WGS-84 and our country Datum Clarck-1880. The results was evaluated and investigated using Carmin GPS device for GCPs comparison, topographic map for Hilla city, mid Iraq 1:100000 scale, and two georefrencing

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Effect of Refractive Index on Photon Natural Mass and Wavelength
...Show More Authors

In this article it is proved experimentally that the photon is a particle that has mass and constant wavelength by explaining the effect of refractive index on the wavelength and the natural mass of photon. It is very difficult to measure the mass of photon, a simple and easy process was proposed in this paper to calculate the mass length of photon in vacuum (Y) and in medium (Y*), by measuring the length of laser beam in air (Lair) and in medium (Lmed). A new method was postulated to calculate refractive index by using these relations (n = Y*/Y), and (n = Lmed / Lair) which supposed a new theory of light.

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Study of Microbial Contamination of Some Commercial Contact Lens Solutions
...Show More Authors

Sixty samples of commercially available contact lens solutions were collected from students at the Pharmacy College/Baghdad University. The types of lenses used varied from medical to cosmetic. They were cultured to diagnose any microbial contamination within the solutions. Both used and unused solutions were subject for culturing. Thirty six (60%) used samples showed bacterial growth, fungal growth was absent. Pseudomonas aeruginosa accounts for the highest number of isolates (25%) followed by E. coli (21%), Staphylococcus epidermidis (6.6%), Pseudomonas fluorescence (5%) and Proteus mirabilis (1.6%) respectively. Only one (1) unused (sealed) sample showed growth of P. fluorescence.

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design of six electrode Enzial electrostatic lens low aberrations for electron gun
...Show More Authors

A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering
Correction Factor for Methods of Installation of Piles Group in Sandy Iraqi Soils
...Show More Authors

Many problems are facing the installation of piles group in laboratory testing and the errors in results of load and settlement are measured experimentally may be happened due to select inadequate method of installation of piles group. There are three main methods of installation in-flight, pre-jacking and hammering methods. In order to find the correction factor between these methods the laboratory model tests were conducted on small-scale models. The parameters studied were the methods of installation (in-flight, pre-jacking and hammering method), the number of piles and in sandy soil in loose state. The results of experimental work show that the increase in the number of piles value led to increase in load carrying ca

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering | University Of Baghdad
Correction Factor for Methods of Installation of Piles Group in Sandy Iraqi Soils
...Show More Authors

Many problems are facing the installation of piles group in laboratory testing and the errors in results of load and settlement are measured experimentally may be happened due to select inadequate method of installation of piles group. There are three main methods of installation in-flight, pre-jacking and hammering methods. In order to find the correction factor between these methods the laboratory model tests were conducted on small-scale models. The parameters studied were the methods of installation (in-flight, pre-jacking and hammering method), the number of piles and in sandy soil in loose state. The results of experimental work show that the increase in the number of piles value led to increase in load carrying capacity of piled raft

... Show More
Publication Date
Sun Jan 01 2023
Journal Name
Acta Facultatis Medicae Naissensis
A correlation between body mass index and refractive errors
...Show More Authors

Background. Body mass index (BMI) is a person's weight in kilograms (or pounds) divided by the square of height in meters (or feet). Obesity affects a wide spectrum of age groups, from the young to the elderly, and there are several eye diseases related to obesity like diabetic retinopathy, floppy eyelid syndrome, retinal vein occlusion, stroke-related vision loss, age-related macular degeneration, and possibly, refractive errors. Refractive errors (RE) are optical imperfections related to the focusing ability of the eye and are the main cause of visual impairment which may result in missed education and employment opportunities, lower productivity and impaired quality of life. Aim. The study aimed to find an association between bod

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref