The objective of this study is to evaluate plasma levels of total Sialic acid TSA and Lipid –associated Sialic acid LSA as a marker of Rheumatoid Arthritis AR. Plasma Sialic acid is known as a parameter of inflammation. In the present study, in order to explore the potential role of sialic acid in arthritis rheumatoid, plasma sialic acid levels, plasma LSA and total protein in patients with arthritis rheumatoid were measured. A total 40 patients were compared with 40 healthy control subjects. Plasma TSA, LSA and TP level were determined spectrophotometrically in plasma samples. Plasma Sialic acid levels were significantly increased in RA (88.48±14.15 mg/dl, P<0.05) and LSA level were significantly increased in RA (26.37±2.25 mg/dl, p<0.05). By contrast there wasn’t any significant elevation of TP in RA patients, compared with healthy control (TSA,53.31±7.58 mg/dl, P<0.05), (LSA,18.46±1.45 mg/dl) and (TP, 7.39±0.34 g/dl).
The biomarker significance of three chemokines (CXCL8, CXCL10 and CXCL16) was evaluated in sera of 45 breast cancer (BC) and 28 benign breast lesion (BBL) patients, as well as 20 control women. Clinical stage and tumor expression of estrogen (ER), progesterone (PgR) and human epidermal growth factor receptor-2 (HER-2) receptors were considered in this evaluation. The results demonstrated that CXCL8, CXCL10 and CXCL16 showed a significant increased median in BC and BBL patients compared to control (CXCL8: 47.3 and 25.7 vs. 15.0; CXCL10: 37.6 and 30.7 vs. 13.1; CXCL16; 27.9 and 25.2 vs. 19.2 pg/ml, respectively). The increased levels of CXCL8 and CXCL16 were more pronounced in triple-negative and HER-2 positive p
... Show MoreIn this research ,Undoped Nio and 1%Li doped Nio thin films were deposited utilizing chemical spray pyrolysis on the glass substrates heated (450C). The effects of non-thermal plasma on the structural and optical properties were studied. XRD measurement shows that Nio and Nio:1%Li films were found to be polycrystalline and have cubic structure with a preferred orientation (111). Decreased crystal size after exposure especially at (7) sec. AFM data indicate that the surface roughness average and (RMS) values of the prepared doped films are increasing after exposure to plasma, the transmittance increases after doped samples exposure to plasma, it was found that the energy gap value decreased when doped samples exposure to plasma, also, thickn
... Show MoreAim: The current study was aimed to determine the relationship between the orthodontic force applied by monobloc and the salivary level of alkaline phosphatase (ALP) and lactate dehydrogenase (LDH) enzymes, considering the time factor after insertion of the appliance and whether there is a correlation between these enzymes. Materials and methods: A sample of 28 growing patients requiring orthodontic treatment with myofunctional appliance (Monoblock) was taken for the current study with an age range 9 to 12 years,all patients had Angle's class II division 1 malocclusion with no or mild crowding, the sample was selected using simple random sampling. Only 16 subjects (10 males and 6 females) were included who follow certain inclusion criteria.
... Show MoreRespiratory tract infections in sheep are among the important health problems that affect all sheep ages around the world. Nine bacterial isolates obtained from sheep with respiratory tract infections were selected to be used in the current study. The isolates included 3 Staphylococcus aureus, 4 Klebsiella pneumoniae, and 2 Pseudomonas aeruginosa. Following the primers design by the Primer3Plus software tool and optimization of the conventional polymerase chain reaction (PCR), the primers were validated for their use in the multiplex PCR experiments. The MFEprimer program was used to check the suitability of the primer set combinations for multiplex PCR. The MFEprimer software was successful in designing the multiplex-PCR experiments and de
... Show MoreThis study was designed to evaluate the effect of major surgery on thyroid hormones and thyrotropin in patient undergoing major lower abdominal surgery. The study included fifty patients scheduled for elective major lower abdominal surgery, the serum levels of T3, T4 and TSH were determined one day preoperatively, intraoperative, one day postoperatively, two days postoperatively, and rT3 was determined one day preoperatively, and one day postoperatively. We observed that the levels of (T3, T4, TSH) increased significantly (P<0.05) intraoperatively, one day postoperatively the levels of T3 and T4 reduced significantly (P<0.05), while TSH reduced not significantly (P>0.05), and two days postoperatively T4 and TSH returned to increase si
... Show MoreThis study explains the effect of non-thermal (cold) plasma on wound of diabetic rats by (FE-DBD) system, 3cm probe diameter is used. The output power was ranged from (12-20) W. The effect of non-thermal plasma on wounds of a diabetic was observed with different exposure durations (20,30) sec., the plasma exposure duration decreases the sugar level in blood and the diameter of the wound. These results indicate the cold plasma can be used to enhance the insulin level (i.e., blood sugar) and wounds treatment.
Abstract
In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3 have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r
... Show MoreCadmium sulphide CdS films with 200 nm have been prepared by thermal evaporation technique on glass substrate at substrate room temperature under vacuum of 10-5mbar.In this paper, the effect of Dielectric Barrier Discharge plasma on the optical properties of the CdS film. The prepared films were exposed to different time intervals (0, 3, 5, 8) min. For every sample, the Absorption A, absorption coefficient α , energy gap Eg ,extinction coefficient K and dielectric constant ε were studied. It is found that the energy gap were decreased with exposure time, and absorption , Absorption coefficient, refractive index, extinction coefficient, dielectric constant increased with time of exposure to the plasma. Our study conside
... Show More