Preferred Language
Articles
/
jih-913
Spectrophotometric Determination of Isoptin (Verapamil Hydrochloride) in Pharmaceutical Preparations
...Show More Authors

Verapamil Hydrochloride (VH) has been determined spectrophotometrically by using Methyl Orange (MO).  In our previous researches MO was used for determination of Mexiletine Hydrochloride [1]. The method was based on complexation between (MO and VH).  After shaking and diluting the complex solution with D.W, the pH was adjusted with NaOH and HCl to pH 4. The colored complex formed between VH and the reagents were transferred into separating funnels and extracted using 4.5 ml CH2Cl2 and were shaken for (4 minutes).  The extracted organic layer was used for the preparation of the calibration curves for spectrophotometric measurements of VH at 437nm.  The blanks were carried out in exactly the same way throughout the whole procedure.  Molar absorptivity (ε L.mol-1.cm-1), detection limit, limit of linearity (µg.ml-1) and r2 were, 1.75*105, 0.009253, 0.08 and 0.993 for (VH-MO) respectively. The method was used with reasonable accuracy and precision for the determination of (VH) in synthetic samples of tablets, capsules and ampoules.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Determination of the Time and Coordinates Required for Measuring the Milky Way’s Rotation Curve Using BURT in 2023
...Show More Authors

     Baghdad University Radio Telescope (BURT) is a 3 meter radio telescope that was installed in the main campus of the University of Baghdad in Jadiriyah. Radio telescopes, in general, offer a wide range of applications in radio astronomy, which are usually used to detect the neutral hydrogen emission line at a wavelength of 21 cm. One of the key applications of BURT is to observe the Milky Way galaxy and to determine its rotation curve. However, performing such observations requires accurate determination of the appropriate observing time as well as the coordinates. This paper focuses on how the observing time and coordinates are calculated correctly and accurately.  The horizontal coordinate that corresponds to the galactic coor

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Modifying Plaque assay and Clearance test as tools in determination of phage typing for E. Coli bacterial interspecies
...Show More Authors

Bacteriophage of E. Coli interspecies from sewage samples were isolated , the phage particles were isolated from two different sewage samples . The first sample was collected from sewage sample of Baghdad university and the second sample was isolated from domestic sewage sample , first sample showed phages specialized for three E. Coli interspecies bacteria (first plate ) and two E. Coli interspecies bacteria (second plate ) , meanwhile second sample showed phage specialized for two E. Coli. interspeciesThe study of appearance of E coli phages from first sample showed three types of E. coli phages with different size of inhibition zone ( 1 , 0.7,0.5 )Cm respectively ( first plate ) , meanwhile E. Coli interspecies bacteria showed phages

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 25 2012
Journal Name
Journal Of Chromatographic Science
Direct Acetylation and Determination of Chlorophenols in Aqueous Samples by Gas Chromatography Coupled with an Electron-Capture Detector
...Show More Authors

A method was developed that offers a rapid, simple and accurate technique for the determination of chlorophenols at trace levels in aqueous samples with very limited volumes of organic solvents. These compounds were acetylated, then preliminarily extracted with n-hexane. The enriched chlorophenols were directly analyzed using gas chromatography with an electron-capture detector. The detection limits were in the range of 0.001–0.005 mg/L, except for 2-chlorophenol, which was always above 0.013 mg/L. Relative standard deviation for the spiked water samples ranged from 2.2 to 6.1%, while relative recoveries were in the range of 67.1 to 101.3%.

View Publication
Scopus (13)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Determination the concentrations of radon gas and exhalation rate in some phosphate fertilizer using CR-39 track detector
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Separation and Micro Determination of Zinc(II) and Cadmium(II) in Food Samples Using Cloud Point Extraction method
...Show More Authors

    The cloud point extraction technique has become increasingly popular in recent years for trace metal separation and preconcentration. When heated to a specific temperature, cloud point extraction utilizes the property of nonionic surfactants in aqueous solutions to generate micelles and become turbid (so-called cloud point temperature). For analytical chemists, developing a simple and selective technology for the separation and determination of metals and medicinal drugs is a critical concern. Therefore, a sensitive, accurate, and green cloud point extraction (CPE) procedure was developed for the micro-determination of metal cations like zinc (II) and cadmium (II) in food samples. Triton X–114 and 1-(4-(Phenyldiazenyl) phenyl) a

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (3)
Scopus Crossref
Publication Date
Mon Oct 03 2016
Journal Name
Applied Research Journal
DETERMINATION OF THE GEOID HEIGHT (GEOID UNDULATION) BY USING MODERN SURVEYING TECHNOLOGIES
...Show More Authors

In this work, a large part of Baghdad University campus has been selected. The determination of Geoidal height for the local area requires Ground Control Points which both Ellipsoidal and Orthometric heights are known to compute the difference between them. The first step of the leveling process began by selected the Ground Control Points (GCPs) around the area of the work, and then divided them into two groups of the network traverse stations. They were leveled and adjusted depend on the number of the Bench Marks (B.M.s). Total Station TS (Nikon Nivo 5C) and Global Positioning System (GPS-Garmin 78 map) are used to do this application. The aim of the proposed work was to determine the height of the Geoid surface in the study area. The Geoi

... Show More
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Total luminescence (Chemiluminescence & Fluorescence)- FIA Method For The Determination of DL-Histidine
...Show More Authors

Histidine was determined via measurement of total luminescence (i:e creation of chemiluminescence and insitu irradiation of released light to an acceptor fluorophore molecule to  initiate fluorescence from fluorescien molecule in flat – spiral micro cell designed for this measurement . A detailed description of robust linear equation for the range of 0.002 – 0.05 mol.L-1 for a sample size of 70 µL with a correlation coefficient of 0.9879 and a coefficient of determination of 97.59% while for a quadratic model of the same concentration range was 0.9881 correlation coefficient and 97.63% coefficient of determination. Analysis of variance was conducted for both kinds of models . It indicated that their was no significa

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 28 2022
Journal Name
Iraqi Journal Of Science
Determination of the shape for (54Xe and 82pb) nuclei from deformation parameters ( , )
...Show More Authors

The shape for even-even (54Xe 118≤ A ≤ 140 and 82Pb 204 ≤ A ≤ 210 ) nuclei have been studied and investigated through the deformation parameters and δ , these deformation parameters were calculated by two different methods. The first one is nucleus quadrupole deformation parameter β2 from reduced transition probability B(E2)↑ for 0+→2+1 transitions and the second is nucleus quadrupole deformation parameters δ from quadrupole moment Qo.The relationship between two deformation parameters ( , ) and neutrons magic number (N=82 & 126) was studied through plotting the deformation parameters ( , ) as a function of neutrons number , from this relationship we can see very cleary that the deformation of nucleus decreased when th

... Show More
View Publication
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Determination of Destruction Levels Caused by Earthquakes Using Grip RADIUS 99 Program
...Show More Authors

The most universal and basic damages caused by an earthquakes are buildings damage and human casualties. A simplified method, the RADIUS 99 Tool is used to calculate seismic intensity (shaking) distribution, buildings damage, number of casualties and lifelines damage, due to assumed earthquake scenario. In this study, Al - Kadhmiya sector in Baghdad city was chosen for assessing seismic risk, for this purpose, this area was divided into mesh of 1*1 km2 cell size, and a scenario of (Manjil) earthquake (that struck Iran in 1990) was utilized with following earthquake magnitudes (5 and 7), with epicenter distance (3, 10 and 100 km), and depths (2 and 5 km). It was found that, the best soil types for constructions are those with medium and h

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Determination of Mono-crystalline Silicon Photovoltaic Module Parameters Using Three Different Methods
...Show More Authors

For modeling a photovoltaic module, it is necessary to calculate the basic parameters which control the current-voltage characteristic curves, that is not provided by the manufacturer. Generally, for mono crystalline silicon module, the shunt resistance is generally high, and it is neglected in this model. In this study, three methods are presented for four parameters model. Explicit simplified method based on an analytical solution, slope method based on manufacturer data, and iterative method based on a numerical resolution. The results obtained for these methods were compared with experimental measured data. The iterative method was more accurate than the other two methods but more complexity. The average deviation of

... Show More
View Publication Preview PDF