Background: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyzed by one way analysis of variance, least significant difference, student's t-test, and Fisher exact test. Results: The mean shear bond strength showed highest values for Resilience adhesive followed by Beauty Ortho Bond and Heliosit adhesives respectively both in dry and wet environments. Interestingly, there was a non-significant difference (P<0.05) between Resilience and Beauty Ortho Bond adhesives using least significant difference at dry environment. In wet environment the Beauty Ortho Bond showed an acceptable mean shear bond strength value (6.39 Mpa) which is considered as a clinically acceptable value. Adhesive remnant index scores demonstrated a tendency towards score 1 in dry environment, and towards score 3 in wet environment, the scores also showed a non-significant difference (P<0.05) between Resilience and Beauty Ortho Bond adhesives using Fischer exact test. Conclusion: Beauty Ortho Bond is less sensitive to wet environment than Resilience and Heliosit adhesives, therefore it has an advantage during clean up, as it reduces the risk of enamel damage during debonding procedure. Keywords: Beauty Ortho Bond, Shear bond strength, light cured composite.
Background: The bond strength of root canal sealers to dentin and gutta-percha seems to be an important property for maintaining the stability of root canal filling, which potentially influences both leakage and root strength. The objective of this, in vitro, study was to evaluate the shear bond strength of three different endodontic sealers (Gutta-Flow, AH Plus, Apexit Plus) to dentin, in the presence and absence of the smear layer and gutta percha. Material and Methods: After slicing off the occlusal 2mm of 60 extracted human maxillary premolar teeth, the exposed dentin served as the tested surfaces; the teeth were fixed with cold cure acrylic, and were divided into two groups according to the smear layer presence, group A without smear
... Show MoreBackground: The bond strength of root canal sealers to dentin was important for maintaining the integrity of the seal in root canal filling in both static and dynamic situations. In a static situation, it should eliminate any space that allowed the percolation of fluids between the filling and the wall while in a dynamic situation; it was needed to resist dislodgement of the filling during subsequent manipulation. Materials and Methods: Forty mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments. Instrumentation was done with copious irrigation of 5.25% sodium hypochlorite. Roots were randomly divided into four groups according to the type of cleaning and method of root canal irrig
... Show MoreTo evaluate the shear bond strength and interfacial morphology of sound and caries-affected dentin (CAD) bonded to two resin-modified glass ionomer cements (RMGICs) after 24 hours and two months of storage in simulated body fluid at 37°C.
Sixty-four permanent human mandibular first molars (32 sound and 32 with occlusal caries, following the International Caries Detection and Assessment System) were selected. Each prepared substrate (sound and CAD) was co
In This research a Spectroscopic complement and Thermodynamic properties for molecule PO2 were studied . That included a calculation of potential energy . From the curve of total energy for molecule at equilibrium distance , for bond (P-O), the degenerated of bond energy was (4.332eV) instate of the vibration modes of ( PO2 ) molecule and frequency that was found active in IR spectra because variable inpolarization and dipole moment for molecule. Also we calculate some thermodynamic parameters of ( PO2 ) such as heat of formation , enthalpy , heat Of capacity , entropy and gibb's free energy Were ( -54.16 kcal/mol , 2366.45 kcal/mol , 10.06 kcal /k/mol , 59.52 k
... Show MoreObjective: To evaluate and compare the effect of mechanical surface treatment (groove, aluminum oxide particles)
with 45 degree bevel type of joint on tensile bond strength of acrylic specimens repaired by two curing methods
(microwave and water both).
Methodology: Eighty specimens (80) were prepared from pink heat cure acrylic resin. They were divided into two
main groups (40 specimen repaired by microwave energy and 40 specimens repaired by water bath method).Each
group can be divided into four subgroups of ten according to the surface treatment. The control group A was left
intact, group B received no surface treatment, group C and D received surface treatment by (groove, 50 m aluminum
oxide particles). Specimens
Background: The present study was carried out to compare shear bond strength of sapphire bracket bonded to zirconium surface after using different methods of surface conditioning and assessment of the adhesive remnant index. Materials and methods: The sample composed of 40 zirconium specimens divided into four groups; the first group was the control, the second group was conditioned by sandblast with aluminum oxide particle 50 μm, the third and fourth group was treated by (Nd: YAG) laser (1064nm)(0.888 Watt for 5 seconds) for the 1st laser group and (0.444 Watt for 10 seconds) for the 2nd laser group. All samples were coated by z-prime plus primer. A central incisor sapphire bracket was bonded to all samples with light cure adhesive res
... Show MoreLead-acid batteries have been used increasingly in recent years in solar power systems, especially in homes and small businesses, due to their cheapness and advanced development in manufacturing them. However, these batteries have low voltages and low capacities, to increase voltage and capacities, they need to be connected in series and parallel. Whether they are connected in series or parallel, their voltages and capacities must be equal otherwise the quality of service will be degraded. The fact that these different voltages are inherent in their manufacturing, but these unbalanced voltages can be controlled. Using a switched capacitor is a method that was used in many methods for balancing voltages, but their respons
... Show MoreThe research presented the experience of creating a new sustainable city, and this experience of establishing an Eco-City (Environmentally friendly) is considered the first experience in Iraq. The current study stressed the importance of the need for environmental planning in the early stages of planning new cities based on realism in planning, design and implementation. Subsequently, that aims to preserve the ecosystem, which is difficult to compensate if degraded or polluted. The research incorporated environmental planning indicators within sustainable urban planning (Reliance on generating electric power that is based on clean and renewable energy sources, Availability of public t
Objectives: This study aimed to identify and study most properties of the specific and general health-related
quality-of-life (HRQoL) in prostate cancer patients, as well as creating a new measurement scale for assessing QoL
among prostate cancer patients.
Methodology: A cross sectional (descriptive) study was conducted to evaluate General Quality of life in patients
with prostate cancer. A sample of 100 prostate cancer patients from Al-Amal National hospital for cancer
management and Oncology Center in Baghdad Medical City. This study applied format of General World Health
Organization Quality of Life-BERF questionnaire. The methods used descriptive statistics to evaluate the General
QoL-Improvements, as well as inf