Preferred Language
Articles
/
jbcd-631
Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium screws. The tibia of 4 white New Zealand rabbits was chosen as implantation sites. Each tibia of rabbit received two screws, one strontium chloride coated and one hydroxyapatite coated and a total 30 histological sections were obtained for each coating material in each period of time. Histomorphometric analysis was performed to measure new bone formed ratio between implant and original bone, after 2 and 6 weeks healing periods. Results: There was increased in new bone formation ratio for the strontium chloride coated implants than hydroxyapatite coated implants and over the two periods of time. There was an increase in the new bone formation ratio at bone-implant interface with time. Conclusion: Coating commercially pure titanium implant with strontium chloride was more efficient in increasing osseointegration at bone implant interface than hydroxyapatite , which was demonstrated by higher new bone formation and maturation at the two periods of time 2 weeks and 6 weeks after implantation. Keywords: Histomorphometric, commercially pure titanium, strontium chloride, hydroxyapatite.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun May 22 2016
Journal Name
Al-mustansiriyah Journal Of Science
Morphological and histological study of the liver in migratory starling bird (Sturnus vulgaris)
...Show More Authors

The present work was aimed to form the baseline data of normal morphological and histological structure features of liver in migratory starling (Sturnus vulgaris). Anatomically, the starling liver bird was dark red -brown in colour and located in the cranial third of the abdominal cavity and consisted of undivided lobes (left and right). The liver right lobe was larger than the left. Histological examination revealed that the liver parenchyma was covered by a connective tissue capsule which appears to be thicker in the rim of liver lobes than other area in the liver lobe. Liver parenchyma was arranged in an unlimited hepatic lobules, which composed of polygonal hepatocytes organized as irregular, radial interconnecting cords or laminae of o

... Show More
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of The College Of Basic Education
A study effect Histological changes in Kidney
...Show More Authors

Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 25 2022
Journal Name
Lubricants
Development of Hybrid Intelligent Models for Prediction Machining Performance Measure in End Milling of Ti6Al4V Alloy with PVD Coated Tool under Dry Cutting Conditions
...Show More Authors

Ti6Al4V alloy is widely used in aerospace and medical applications. It is classified as a difficult to machine material due to its low thermal conductivity and high chemical reactivity. In this study, hybrid intelligent models have been developed to predict surface roughness when end milling Ti6Al4V alloy with a Physical Vapor Deposition PVD coated tool under dry cutting conditions. Back propagation neural network (BPNN) has been hybridized with two heuristic optimization techniques, namely: gravitational search algorithm (GSA) and genetic algorithm (GA). Taguchi method was used with an L27 orthogonal array to generate 27 experiment runs. Design expert software was used to do analysis of variances (ANOVA). The experimental data were

... Show More
View Publication
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SPECTROPHTOTOMETRIC DETERMINATION OF PURE SULFAMETHOXAZOLE IN PHARMACEUTICAL PREPARATIONS BY OXIDATIVE COUPLING REACTION: SPECTROPHTOTOMETRIC DETERMINATION OF PURE SULFAMETHOXAZOLE IN PHARMACEUTICAL PREPARATIONS BY OXIDATIVE COUPLING REACTION
...Show More Authors

            A new, simple, rapid and sensitive spectrophotometric method for the determination of sulfamethoxazole in both pure form and pharmaceutical preparations has been reported.The adapted technique based on utilization 4-aminobenzene sulfonic acid as a new modern chromogenic through an oxidative coupling reaction with sulfamethoxazole and potassium iodate in basic media to form orange soluble dye product with absorption maxima at 490 nm. Subject to Beer's law in the range 2–32μg mL-1. The values of molarabsorption coefficient (ε) and correlation coefficient were found to be 9.118 × 103 and0.9999 respectively whereas the Sandels index was

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Lipid Profile and Fasting Blood Sugar Analysis in Patients with Cholelithiasis
...Show More Authors

Cholelithiasis is one of the commonest surgical problems and one of the most common gastrointestinal diseases throughout the world but its pathogenesis remains unclear. Many theories have been proposed forward to explain the mechanism of stone formation. It is not fully clear if symptomatic gallstone disease is associated with a specific pattern of some biochemical abnormalities, as lipid profile and fasting blood sugar in serum of patients.

This study was designed to estimate lipid profile and fasting blood sugar in the sera of patients with cholelithiasis in comparison with normal individuals (control).

In this study, 104(male=16, female=88) were symptomatic gallstone patients (aged 42.79± 12.18 years), and 38(male=6

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Wasit Journal Of Engineering Sciences
Analysis attackers’ methods with hashing secure password using CSPRNG and PBKDF2
...Show More Authors

Using the Internet, nothing is secure and as we are in need of means of protecting our data, the use of passwords has become important in the electronic world. To ensure that there is no hacking and to protect the database that contains important information such as the ID card and banking information, the proposed system stores the username after hashing it using the 256 hash algorithm and strong passwords are saved to repel attackers using one of two methods: -The first method is to add a random salt to the password using the CSPRNG algorithm, then hash it using hash 256 and store it on the website. -The second method is to use the PBKDF2 algorithm, which salts the passwords and extends them (deriving the password) before being ha

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Sat Aug 29 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Biomechanical evaluation of porous titanium implants (CpTi) fabricated by powder technology
...Show More Authors

Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um part

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Ecological Engineering
Biosynthetic of Titanium Dioxide Nanoparticles Using Zizyphus Spina-Christi Leaves Extract
...Show More Authors

View Publication
Scopus (15)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Tue Dec 27 2022
Journal Name
Journal Of Lasers In Medical Sciences
Influence of Fiber Laser (1064 nm) on Shear Bond Strength of Titanium Abutment and Resin Cement
...Show More Authors

Introduction: The present study was performed to evaluate the influence of a 1064 nm fiber laser on shear bond strength (SBS) at the interface of titanium and resin cement. Methods: Forty titanium discs of 6 mm × 3 mm (diameter and thickness respectively) were categorized into four groups (n=10): control group without any surface treatment and three groups treated with a fiber laser with 81 ns pulse duration, 30 kHz frequency, 10000 mm/s scanning speed, 0.05 mm spot size, and different average power values (3, 5 and 7 W) depending on the tested group. Titanium disc characterization was performed by the scanning electron microscope (SEM) and surface roughness tester. Phase analysis was achieved using an X-ray diffractometer (XRD). F

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref