Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium screws. The tibia of 4 white New Zealand rabbits was chosen as implantation sites. Each tibia of rabbit received two screws, one strontium chloride coated and one hydroxyapatite coated and a total 30 histological sections were obtained for each coating material in each period of time. Histomorphometric analysis was performed to measure new bone formed ratio between implant and original bone, after 2 and 6 weeks healing periods. Results: There was increased in new bone formation ratio for the strontium chloride coated implants than hydroxyapatite coated implants and over the two periods of time. There was an increase in the new bone formation ratio at bone-implant interface with time. Conclusion: Coating commercially pure titanium implant with strontium chloride was more efficient in increasing osseointegration at bone implant interface than hydroxyapatite , which was demonstrated by higher new bone formation and maturation at the two periods of time 2 weeks and 6 weeks after implantation. Keywords: Histomorphometric, commercially pure titanium, strontium chloride, hydroxyapatite.
This study showed that liver of Passer domesticus bilobed the right lobe is cardiac shape while the left is elliptical and the liver colour is brown. It is occupying most of anterior and middle parts of abdominal cavity. The liver is surrounded by Glison capsule which is represented by a thin layer of connective tissue with septum extend peripherally in liver tissue. The liver tissue is formed from polyhedral hepatocyte arrange as irregular hepatic cord surrounded the central vein. Each cell contains one or two nucleus with one or more nucleolus. The blood sinusoid appeared between the liver cells .The hepatic cord arranged radially around the central vein. The portal area is clear and surrounded by connective tissue. Gallbladder is almost
... Show MoreThe present work was aimed to form the baseline data of normal morphological and histological structure features of liver in migratory starling (Sturnus vulgaris). Anatomically, the starling liver bird was dark red -brown in colour and located in the cranial third of the abdominal cavity and consisted of undivided lobes (left and right). The liver right lobe was larger than the left. Histological examination revealed that the liver parenchyma was covered by a connective tissue capsule which appears to be thicker in the rim of liver lobes than other area in the liver lobe. Liver parenchyma was arranged in an unlimited hepatic lobules, which composed of polygonal hepatocytes organized as irregular, radial interconnecting cords or laminae of o
... Show MoreThe results of the current study showed that the thyroid gland in adult domestic cat (Felis catus) is located in the neck area on both sides of the trachea at rings (1-5). The gland consists of two lobes (right and left) and it is surrounded by a capsule of connective tissue consisting of two outer and inner layers, and a layer of fatty tissue overlaps with the outer layer of the capsule. In addition, the results of this study found that the histological structure of the thyroid gland is composed of several follicles that appear in different sizes and shapes; the follicles are lined with simple cuboidal epithelial tissue and sometimes appear lined with high and low simple cuboidal epithelial tissue. The gland is histologically composed of t
... Show MoreIn this work, the occurrence conditions of both local Bifurcation and persistence were studied, Saddle-node bifurcation appears near fourth point, near the first point, the second point and the third point a transcritical bifurcation occurred but no pitchfork bifurcation happened near any of the four equilibrium points. In addition to study conditions for Hopf-bifurcation near positive stable point that is the fourth point. Besides discuss persistence occurrence as globally property of the food chain of three species include prey, first predator and top predator with impact of toxin in all species and harvesting effect on the predator’s only. Numerical results for the set of hypothe
Some new complexes of 4-(5-(1,5-dimethyl-3-oxo-2-phenyl pyrazolidin-4- ylimino)-3,3-dimethyl cyclohexylideneamino) -1,5- dimethyl-2- phenyl -1H- pyrazol -3(2H) –one (L) with Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Pd(II), Re(V) and Pt(IV) were prepared. The ligand and its metal complexes were characterized by phisco- chemical spectroscopic techniques. The spectral data were suggested that the (L) as a neutral tetradentate ligand is coordinated with the metal ions through two nitrogen and two oxygen atoms. These studies revealed Octahedral geometries for all metal complexes, except square planar for Pd(II) complex. Moreover, the thermodynamic activation parameters, such as ?E*, ?H, ?S, ?G and K are calculated from the TGA curves using Coa
... Show MoreBackground: Both bladder cancer and schistosomiasis are endemic in Egypt. The former has a unique epidemiological pattern, which has been linked to bladder infestation by Schistosoma. The last decades have witnessed a great reduction in the infection rate of schistosomiasis and a decline in the incidence and changes in the patterns of bladder cancer. Whether these changes are linked to each other or a co-incidence is a subject of investigations.
Method: Literature on epidemiological data of bladder cancer and Schistosoma in Egypt was searched for in Medline, Scopus, PubMed, and Google Scholar. Furthermore, a hand search for literature and reports released by the Egyptian government and involved agencies was perfo
... Show MoreThis paper was aimed to evaluate the polyurethane (PU) and polyurethane/polyvinyl chloride (90 wt. % / 10 wt. %) as organic coating of carbon steel substrate against marine environment (3.5 wt.% NaCl aqueous solution) as a severe corrosion environment . The electrochemical impedance spectroscopy (EIS) and fitting impedance data by ZsimpWin 3.22 software were used to estimate the physical barrier of the samples for different exposure times. Different equivalent electrical circuits were proposed for the physical barrier at different immersion times to get appropriate fitting .Both PU and PU/PVC coatings showed excellent corrosion protection ability for steel .The PU/PVC coating showed better protection and stability than PU coating against
... Show More