Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial stability of dental implants’ design was compared with initial stability of dental implants of the same dimensions and design that engage horizontal plates of 1.5mm thickness at the apical part. All dental implants were implanted into a solid rigid polyurethane foam blocks (artificial bone) of 0.48g/cm3 density and tested by the five initial stability tests. Each test was done with forty samples (twenty samples of 5mm length and twenty samples of 10mm length). Results: The statistical analysis was performed and the result showed that there was very highly significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both 5mm and 10 mm lengths in four initial stability tests which were insertion torque, removal torque, push-in test and pull-out test. The statistical analysis of the resonance frequency analysis showed that there was non-significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both lengths. Conclusion: These results implied that the dental implants with the horizontal plates had better primary stability compared with the dental implants without the horizontal plates confirming that the horizontal plates enhanced the primary stability of the dental implants.
The current study aimed to isolate and diagnose the fungi associated with the inflammatory bowel disease patients with 150 samples distributed between 50 samples from Crohn's patients and 50 samples from ulcerative colitis patients, 50 control from Al-Kindy Al Teaching Hospital in Baghdad, Baghdad. Five types of yeast were isolated and identified, namely C. albicans, C.glabarta, Tropicales, C. parapsilosis, C. and C., krusi C. parapsilosis and.and Aspergillus, Penicillium, Muocer, Rhizopous, Saccharomycosis, and Cryptococcus, The results indicated the dominance of Candida spp. In crohn’s disease, the frequency of isolated Candida albicans was 24 (58.54%), Candida glabrata 11 (26.86%), Candida tropicalis 5 (12.2%) and Candida krusi was 1 (
... Show MoreThe aim of the present study was to demonstrate the possible role of statins on the inflammatory biomarkers in patients with periodontal disease (PD) This cross-sectional study involved 74 patients with PD and/or dyslipidemia divided into Group A: 34 patients with PD (nonstatins users); Group B: 40 patients with PD (statins users); and Group C: 30 healthy controls. Total cholesterol (TC), triglyceride (TG) and high-density lipoprotein, C-reactive protein (CRP), interleukin-6 (IL-6), tumor necrosis factor alpha (TNF-α), and malondialdehyde (MDA) were measured . Blood pressure prolife and indices of PD were evaluated in each group. Statistical analysis was conducted by using SPSS version 20.0.
A finite element is a study that is capable of predicting crack initiation and simulating crack propagation of human bone. The material model is implemented in MATLAB finite element package, which allows extension to any geometry and any load configuration. The fracture mechanics parameters for transverse and longitudinal crack propagation in human bone are analyzed. A fracture toughness as well as stress and strain contour are generated and thoroughly evaluated. Discussion is given on how this knowledge needs to be extended to allow prediction of whole bone fracture from external loading to aid the design of protective systems.
Theoretical and experimental investigations of free convection through a cubic cavity with sinusoidal heat flux at bottom wall, the top wall is exposed to an outside ambient while the other walls are adiabatic saturated in porous medium had been approved in the present work. The range of Rayleigh number was and Darcy number values were . The theoretical part involved a numerical solution while the experimental part included a set of tests carried out to study the free convection heat transfer in a porous media (glass beads) for sinusoidal heat flux boundary condition. The investigation enclosed values of Rayleigh number (5845.6, 8801, 9456, 15034, 19188 and 22148) and angles of inclinations (0, 15, 30, 45 and 60 degree). The numerical an
... Show Morebased search on two variables two main (Administrative empowerment ) and (technical innovation) target detection relationship and influence between the five dimensions (the delegation of authority , personnel training , effective communication, work teams , motivating employees) and
(technical innovation) conducted research in General Company for electrical Industries , and through the sample included the views of managers in the various administrative levels poll .
And adopted a researcher at a major tool for data collection is questionnaire designed to find, as was the contents of the questionnaire analysis according to the Statistical Information System ( Spss), The (55) to identi
... Show More