Preferred Language
Articles
/
jbcd-593
Evaluation of shear bond strength of artificial teeth to heat cure acrylic and high impact heat cure acrylic using autoclave processing method
...Show More Authors

Background: Debonding and fracture of artificial teeth from denture bases are common clinical problem, bonding of artificial teeth to heat cure acrylic and high impact heat cure acrylic denture base materials with autoclave processing method is not well known. The aim of this study was to evaluate the effect of autoclave processing method on shear bond of artificial teeth to heat cure denture base material and high impact heat cure denture base material. Materials and methods: Heat polymerized (Vertex) and high impact acrylic (Vertex) acrylic resins were used. Teeth were processed to each of the denture base materials after the application of different surface treatments. The sample (which consist of artificial tooth attached to the denture base at 45 degree) are consist of (80) artificial teeth from the same model of central incisor, they were prepared , treated and bonded to the conventional heat cured and high impact acrylic denture base material then processed. Control group (Group A 40 samples) in which acrylic resins PMMA cured by conventional water- bath processing technique (74°C for 1.5 hours then boil for 30 minutes),the group was subdivided to 20 samples heat cure acrylic and 20 samples high impact acrylic. Experimentalgroups (Group B 40 samples) in which acrylic resins was cured by autoclave at 121°C, 210KPa. For 30min.the group subdivided to 20 samples heat cure acrylic and 20 samples high impact acrylic. For each subgroup, the 20 samples were subdivided according to surface treatment into: 1-Five acrylic teeth without any surface treatment (control). 2- Five acrylic teeth with diatoric preparation (retention grooves). 3- Five acrylic teeth conditioned with thinner. 4- Five acrylic teeth with retention grooves and thinner. Results: Statistical analysis revealed that chemical and mechanical treatment of acrylic teeth improved the shear bond with heat cure and high impact acrylicalsoautoclave processing improvedthe shear bond with acrylic teeth in high impact acrylic. Conclusion: Autoclave polymerization is suggested as alternative method for processing denture base resins. Autoclave polymerization can be easily performed in laboratory conditions. In High Impact Acrylic, there were highly significant differences of autoclave processing technique compared with water bath regarding the shear bond strength with acrylic teeth.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Mathematical Modelling And Numerical Optimisation
Reconstruction of an orthotropic thermal conductivity from non-local heat flux measurements
...Show More Authors

View Publication
Scopus (8)
Crossref (1)
Scopus Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Engineering
Investigation of Optimum Heat Flux Profile Based on the Boiling Safety Factor
...Show More Authors

An experimental study is conducted to investigate the effect of heat flux distribution on the boiling safety factor of its cooling channel. The water is allowed to flow in a horizontal circular pipe whose outlet surface is subjected to different heat flux profiles. Four types of heat flux distribution profiles are used during experiments: (constant distribution profile, type a, triangle distribution profile with its maximum in channel center, type b, triangle distribution profile with its maximum in the channel inlet, type c, and triangle distribution profile with its maximum in the channel outlet, type d). The study is conducted using heat sources of (1000 and 2665W), water flow rates of (5, 7 and 9 lit/min). The water

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Parametric Study of Mixed Convective Radiative Heat Transfer in an Inclined Annulus
...Show More Authors

The steady state laminar mixed convection and radiation through inclined rectangular duct with an interior circular tube is investigated numerically for a thermally and hydrodynamicaly fully developed flow. The two heat transfer mechanisms of convection and radiation are treated independently and simultaneously. The governing equations which used are continuity, momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C) methods. The finite difference approach with the Line Successive Over-Relaxation (LSOR) method is used to obtain all the computational results. The (B.F.C) method is used to generate the grid of the problem. A computer program (Fortran

... Show More
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Effect of Air Bubbles on Heat Transfer Coefficient in Turbulent Convection Flow
...Show More Authors

Experimental and numerical studies have been conducted for the effect of injected air bubbles on the heat transfer coefficient through the water flow in a vertical pipe under the influence of uniform heat flux. The investigated parameters were water flow rate of (10, 14 and 18) lit/min, air flow rate of (1.5, 3 and 4) lit/min for subjected heat fluxes of (27264, 36316 and 45398) W/m2. The energy, momentum and continuity equations were solved numerically to describe the motion of flow. Turbulence models k-ε was implemented. The mathematical model is using a CFD code Fluent (Ansys15). The water was used as continuous phase while the air was represented as dispersed. phase. The experimental work includes design, build and instrument a test

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Using Texture Analysis Image Processing Technique to Study the Effect of Microwave Plasma on the Living Tissue
...Show More Authors

The present study is a hybrid method of studying the effect of plasma on the living tissue by using the image processing technique. This research explains the effect of microwave plasma on the DNA cell using the comet score application, texture analysis image processing and the effect of microwave plasma on the liver using texture analysis image processing. The study was applied on the mice cells. The exposure to the plasma is done by dividing the mice for four groups, each group includes four mice (control group, 20, 50, 90 second exposure to microwave plasma). The exposure to microwave plasma was done with voltage 175v and gas flow on 2 with room temperature; the statistical features are obtained from the comet score images and the textur

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Structural Engineering
Experimental and Numerical Evaluation of a Welded Demountable Shear Connector through Horizontal Pushout Tests
...Show More Authors

A novel welded demountable shear connector for sustainable steel-concrete composite structures is proposed. The proposed connector consists of a grout-filled steel tube bolted to a compatible partially threaded stud, which is welded on a steel section. This connector allows for an easy deconstruction at the end of the service life of a building, promoting the reuse of both the concrete slabs and the steel sections. This paper presents the experimental evaluation of the structural behavior of the proposed connector using a horizontal pushout test arrangement. The effects of various parameters, including the tube thickness, the presence of grout infill, and the concrete slab compressive strength, were assessed. A nonlinear finite element mode

... Show More
View Publication
Scopus (19)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis and evaluation of B-cyclodextrin Based Nanosponges of 5- Fluorouracil by Using Ultrasound Assisted Method
...Show More Authors

 

CD-nanosponges were prepared by crosslinking B-CD with diphenylcarbonate (DPC) using ultrasound assisted technique. 5-FU was incorporated with NS by freeze drying, and the phase solubility study, complexation efficiency (CE) entrapment efficiency were performed. Also, the particle morphology was studied using SEM and AFM. The in-vitro release of 5-FU from the prepared nanosponges was carried out in 0.1N HCl.

5-FU nanosponges particle size was in the nano size. The optimum formula showed a particle size of (405.46±30) nm, with a polydispersity index (PDI) (0.328±0.002) and a negative zeta potential (-18.75±1.8). Also the drug entrapment efficiency varied with the CD: DPC molar ratio from 15.6 % to 30%. The SEM an

... Show More
View Publication Preview PDF
Scopus (18)
Crossref (5)
Scopus Crossref
Publication Date
Tue Apr 02 2024
Journal Name
Engineering, Technology & Applied Science Research
Two Proposed Models for Face Recognition: Achieving High Accuracy and Speed with Artificial Intelligence
...Show More Authors

In light of the development in computer science and modern technologies, the impersonation crime rate has increased. Consequently, face recognition technology and biometric systems have been employed for security purposes in a variety of applications including human-computer interaction, surveillance systems, etc. Building an advanced sophisticated model to tackle impersonation-related crimes is essential. This study proposes classification Machine Learning (ML) and Deep Learning (DL) models, utilizing Viola-Jones, Linear Discriminant Analysis (LDA), Mutual Information (MI), and Analysis of Variance (ANOVA) techniques. The two proposed facial classification systems are J48 with LDA feature extraction method as input, and a one-dimen

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Jan 02 2017
Journal Name
Al-nahrain Journal For Engineering Sciences (njes)
Experimental Investigation of Forced Convection Heat Transfer and Pressure Drop in Open Cell Aluminum Fins
...Show More Authors

Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Heat Transfer Analysis of Conventional Round Tube and Microchannel Condensers in Automotive Air Conditioning System
...Show More Authors

In this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel

... Show More
View Publication Preview PDF
Crossref (1)
Crossref