Background: Controversy exists concerning the presence and amount of the Bennett mandibular immediate side shift among patients and whether it is necessary to accommodate for it in adjustable articulators. The aim of this study was to register and calculate the amount of any immediate side shift (ISS) present in patients requiring full mouth rehabilitation. Materials and methods: 3- dimensional condylar movements of 50 Iraqi TMD-free patients were recorded using a stereographic fully adjustable articulator system during protrusion, left and right eccentric mandibular movements. Protrusive angles of each patient were verified to figure out the suitable fossa analog for each case. The thickness of each right and left premade fossa analog selected was measured with a vernier caliper and was tightly secured in the articulator fossa compartment. Functionally-generated path recordings were performed using custom-made intraoral clutches. Bennett ISSs, verified by the stereographic system in the molded fossae, were measured using the vernier caliper. The final right and left ISSs were estimated by subtracting the thickness of the blank fossa analog from that of the molded one. The final ISSs were recorded and statistically compared. Results: Stereographic recordings of eccentric mandibular movements revealed ISSs within all patients involved in this study. The ISSs varied among the patients and bilaterally within them. Their average values ranged between 0.80 mm for females and 1.68 mm for males, showing significant statistical differences between them but with no relevancy to age advancement. Mean values of ISSs of males' and females' mandibular left joints were more than those recorded by their right joints. Conclusion: Verifying the mandibular ISS in the molded fossae is an essential step to efficiently rehabilitate full mouth cases; thus it would be helpful to use a fully adjustable articulator system to restore complicated cases since very minor intraoral occlusal adjustments might be required for the finished restorations prior to the final cementation.
In this article, performing and deriving te probability density function for Rayleigh distribution is done by using ordinary least squares estimator method and Rank set estimator method. Then creating interval for scale parameter of Rayleigh distribution. Anew method using is used for fuzzy scale parameter. After that creating the survival and hazard functions for two ranking functions are conducted to show which one is beast.
The charge transfer at C23H17F8N8O2PRu, C44H30BF4N5O4Ru, C56H52CL5N5OOsP2 and C76H88F80N24O11P10Ru4 nitrosyl complexes are investigation and studies theoretically using the quantum consideration. Charge transfer behavior largely rely to the electric properties of nitrosyl complexes system whose depending on the main important parameters for the transmission rate constant such that: orientation transition energy, overlapping coupling coefficient, driving force energy, height barrier and Temperature T (K). Data results have been evaluated using a MATLAB program. Results show that rate of charge transfer increases due to increases the orientation transition energy.
In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.
In this research we assumed that the number of emissions by time (𝑡) of radiation particles is distributed poisson distribution with parameter (𝑡), where < 0 is the intensity of radiation. We conclude that the time of the first emission is distributed exponentially with parameter 𝜃, while the time of the k-th emission (𝑘 = 2,3,4, … . . ) is gamma distributed with parameters (𝑘, 𝜃), we used a real data to show that the Bayes estimator 𝜃 ∗ for 𝜃 is more efficient than 𝜃̂, the maximum likelihood estimator for 𝜃 by using the derived variances of both estimators as a statistical indicator for efficiency
By driven the moment estimator of ARMA (1, 1) and by using the simulation some important notice are founded, From the more notice conclusions that the relation between the sign and moment estimator for ARMA (1, 1) model that is: when the sign is positive means the root gives invertible model and when the sign is negative means the root gives invertible model. An alternative method has been suggested for ARMA (0, 1) model can be suitable when
In this study the design and installation of evaporative air cooler was carried out using completely outdoor air (fresh air) according to two stage evaporative cooling principle. The laboratory equipment was installed by designing and manufacturing a cross flow plate heat exchanger, where aluminum plates used for this purpose with dimensions (50 × 30 × 40 cm). The surfaces of heat exchanger were covered by sawdust from wetted channels side, to increase the percentage of wetting these surfaces and hence improve the performance and efficiency of air cooler.
An experimental study was carried out to estimate the performance of cooling system, where som
... Show MoreBackground: Diabetes mellitus a major factor that has adverse effects on the vascular system and the heart. It causes an increase in cardiac muscle thickness, resulting in decreased compliance and increased peripheral arterial stiffness. This study aims to assess the left ventricular mass (LVM) and left ventricular hemodynamic changes in diabetic patients measured by Doppler echocardiography. Patients and Methods: The study included 50 diabetic patients ranging in age between 25 and 80 years, (mean age: 54.1 ± 15.10, 19 males, 31 females) and 50 healthy subjects, aged 25 to 80 years (mean age: 48.52 ± 14.45, 11 males, 39 females). Doppler echocardiography was used to assess left ventricular function. The measurements included
... Show MoreObjective: To assess the major anti-tuberculosis drugs available to patients at primary health care centers in Baghdad city. Methodology: A descriptive cross-sectional study design is carried out in order to achieve the objectives of the study by using the assessment technique in primary health care centers from December 29th, 2014 to July 10 th, 2015. probability sampling is select based on the study design. Eighteen primary health care centers are select according to criteria of sample to the study and for the purpose of the study, is select (6) sectors and (11) Primary Health Care Centers (PHCC) from Bagh
IFRS 17 aims to provide a unified basis for accounting for all types of insurance contracts, including reinsurance contracts, in a manner that benefits both investors and insurance companies and enhances the ability of the financial statements of insurance companies for comparison between companies listed in financial markets around the world. According to this standard, insurance contracts are accounted for on the basis of the Asset-Liability Approach and the use of fair values that the standard requires updating regularly in order to provide more useful information to the users of financial statements, as a result of the failure of reporting requirements for insurance contr
... Show More