Preferred Language
Articles
/
jbcd-509
Micro CT analysis of amount of dentin removal created by SAF vs. ProTaper systems
...Show More Authors

Background: Dentin removed during root canal system instrumentation for creating adequate geometry for the canal and cleaning the canal. A new instrument had been marketed with the aim of optimum shaping of all parts of the canal system, however, no information present about the amount of dentin removal compared to conventional rotary system. This study investigated the amount of dentin removal when the canal instrumented by SAF compared with ProTaper by using high resolution computed tomography (micro CT). Materials and Methods: Twenty extracted single canalled teeth were utilized for this study; and randomly divided into 2 groups. In the first group, the root canals were prepared by using protaper rotary system till F2 and the root canal irrigated with 1ml of normal saline after each instrument. The root canals in the second group were prepared using SAF for 2min, with continuous irrigation (normal saline). After rescanning, the amount of dentin removal was calculated. Result: It was clear that the use of SAF system had increase the amount of dentin removal and in quantity larger than that did by ProTaper system & the mean of net difference was (0.288mm ± 0.051). By using t-independent test, there was highly significant difference between the two groups at (p=0.001), with in favor of the SAF system over ProTaper system at p< 0.01; in dentin removal quantity Conclusion: Root canal preparation with SAF-system resulted in more and effectively removed dentin when compared with protaper rotary files.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Synthesis and Characterization of Nanocrystalline Micro-Mesoporous ZSM-5/MCM-41 Composite Zeolite
...Show More Authors

Nanocrystalline micro-mesoporous ZSM/MCM-41 composite was synthesized using alkaline treatment method and two step of crystallization in poly tetraflouroethylene (PTFE) lined autoclave. The synthesized zeolites was characterized by X-Ray diffraction (XRD), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM), Atomic force microscopy (AFM), Fourier transport infrared (FTIR), and N2 adsorption-desorption (BET). It was approved that the best results for alkaline leaching can be got with 1.5M NaOH solution. High surface (BET) area of 630 m2/g with pore volume of 0.55 cm3/g has been got. AFM reports showed a nano-level size for average particle size of 50nm.

View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Micro and Nano Material on Critical Heat Flux (CHF) Enhancement
...Show More Authors

The Nano materials play a very important role in the heat transfer enhancement. An experimental investigation has been done to understand the behaviors of nano and micro materials on critical heat flux. Pool boiling experiments have used for several concentrations of nano and micro particles on a 0.4 mm diameter nickel chrome (Ni-Cr) wire heater which is heated electrically at atmospheric pressure. Zinc oxide(ZnO) and silica(SiO2) were used as a nano and micro fluids with concentrations (0.01,0.05,0.1,0.3,0.5,1 g/L), a marked enhancement in CHF have been shown in the results for nano and micro fluids for different concentrations compared to distilled water. The deposition of the nano particles on the heater surface was the rea

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
The Effects of micro Aluminum fillers In Epoxy resin on the thermal conductivity
...Show More Authors

View Publication
Scopus (29)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Effect of Dentin Surface Pretreatment With Chitosan Nanoparticles on Immediate and Prolonged Shear Bond Strength of Resin Composite: An in Vitro Study
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Nov 03 2023
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
The Effectiveness of Autogenous Dentin Graft as a Biomaterial in Optimizing the Esthetic Outcomes of Immediate Dental Implants: A Prospective Clinical Study
...Show More Authors

Background: Immediate implant placement in the maxillary anterior region was challenging, especially with the jumping gap and limited primary implant stability. Objective: To assess the autogenous dentin graft biomaterial's ability to improve the esthetic outcomes of an immediately inserted implant. Methods: Twenty patients with non-restorable retained roots in the maxillary non-molar region surrounded by natural sound teeth were included in this study after a complete clinical and radiological examination, including patient health and clinical fitness for the immediate dental implant procedure. A single dental implant was inserted for each patient, and the resulting jump distance was filled with the mineralized dentin graft and co

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Tue Dec 15 2015
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Extraction of Fish Oils and Used in Drugs Systems.: Extraction of Fish Oils and Used in Drugs Systems.
...Show More Authors

In this study was undertaken frish fish such as Bigeye Ilisha megaloptera, Nematalos nasus, Suboor Hilsha ilisha and Carp Cyprinus carpio. they were purchased from local marketes in Basrah, Oil was extracted by a solvent extraction method on low temperature. And the level of oil obtiened about (6.08; 10.72; 13.52 and 5.61)% for Bigeye, Jaffout, Suboor and Carp. the Crud oils were compared with vegetable oil (olive oil) and animal fat (tial fat mutton).
The extracted oil from fresh complete fishs with compared oils intraed on pharmacological system through packed in capsul with and with out garlic`s extract. this system analysis with chemical tests.
Results were analyzed statistically by using the SPSS program with using (CRD)

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrosorption of Hexavalent Chromium Ions by MnO2/Carbon Fiber Composite Electrode: Analysis and Optimization of the Process by Box-Behnken Design
...Show More Authors

A nano manganese dioxide (MnO2) was electrodeposited galvanostatically onto a carbon fiber (CF) surface using the simple method of anodic electrodeposition. The composite electrode was characterized by field emission scanning electron microscopy (FESEM), and X-ray diffraction (XRD). Very few studies investigated the efficiency of this electrode for heavy metals removal, especially chromium. The electrosorption properties of the nano MnO2/CF electrode were examined by removing Cr(VI) ions from aqueous solutions. NaCl concentration, pH, and cell voltage were studied and optimized using the Box-Behnken design (BDD) to investigate their effects and interactions on the electrosorption process. The results showed that the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Desalination And Water Treatment
The removal of Pb(II) ions from aqueous solutions by immobilized (Chlorophyta) macroalgae: an equilibrium, kinetic, and desorption-regeneration study
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Removal of Malachite Green from Aqueous Solution using Ficus Benjamina Activated Carbon-Nonmetal Oxide synthesized by pyro Carbonic Acid Microwave
...Show More Authors

Activated carbon derived from Ficus Binjamina agro-waste synthesized by pyro carbonic acid microwave method and treated with silicon oxide (SiO2) was used to enhance the adsorption capability of the malachite green (MG) dye. Three factors of concentration of dye, time of mixing, and the amount of activated carbon with four levels were used to investigate their effect on the MG removal efficiency. The results show that 0.4 g/L dosage, 80 mg/L dye concentration, and 40 min adsorption duration were found as an optimum conditions for 99.13% removal efficiency. The results also reveal that Freundlich isotherm and the pseudo-second-order kinetic models were the best models to describe the equilibrium adsorption data.

 

View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Desalination And Water Treatment
Optimization of chemical oxygen demand removal from petroleum refinery wastewater by electrocoagulation using tubular electrochemical reactor with a novel design
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref