Preferred Language
Articles
/
jbcd-2923
Comparison between the mesiodistal crown dimensions of second primary molar with stainless steel crowns from different companies
...Show More Authors

Background: Due to the variations in tooth anatomy and size among different populations, this study aimed to compare the mesiodistal width of primary second molars in Iraqi children with the mesiodistal width of stainless-steel crowns from different companies. Materials and Methods: This cross-sectional study was conducted on 220 intact maxillary and mandibular primary second molars selected from boys and girls’ Iraqi children aged 8-9 years collected from different primary schools in Baghdad city. The mesiodistal dimensions of the selected teeth and the available maxillary and mandibular stainless-steel crowns from three different companies were measured by using a 3-D scanner, and then the whole measurements were calculated using 3 shape Ortho-analyzer software program. Results: Data were analyzed statistically via SPSS V 26 software and the results showed that there’s non-significant difference between the MD measurements of second primary molars between right and left sides, and high significant difference were recorded with higher mean values for boys than girls. When comparing the same mesiodistal measurement between molars with that of stainless-steel crowns, only limited sizes of stainless steel crowns were found to be fitted to the molars of Iraqi children. Conclusion: more studies need to be applied using other stainless steel crown companies to find the relation in the mesiodistal measurement of Iraqi populations.

 

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 01 2009
Journal Name
Baghdad Science Journal
The Relationship Between Hyperglycemia and the Rheumatoid Factor in the Serum of Diabetic Patients
...Show More Authors

This study was conducted to determine the relationship between two most common diseases in Iraqis patients , which are Diabetic mellitus (DM) and Rheumatoid Arthritis (RA); seeking rheumatoid factor in hyperglycemic sera. The results revealed that ; 62.5% of hyperglycemic (HG) patients had positive rheumatoid factor (RF) . No difference in number between both gender of HG patients (20 males and 20 females ) , RF reaction was nearly similar in males and females of HG patients ( 12 &13 respectively ) . Only 40% out of patient controls had positive RF . None of the apparently healthy subjects had positive RF .

View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Corrosion behavior of mild-steel in cooling towers using high salinity solution
...Show More Authors

Cooling towers is one of the most important unit in industry, they are used to dispose heat from cooling media used in the integrated units. The choice of the cooling media plays recently an important rule due to fresh-water scarcity. The use of saline as a cooling media become of growing interest, but the corrosion problem has to be taken in consideration. In this study the simultaneous effect of cooling tower operation parameters on the corrosion rate of mild-steel is considered. The role of NaCl content is found to be pronounced more than the working solution temperature and flowrate. The corrosion of mild-steel in these studied factors had shown an interesting result especially with the NaCl% content. Firstly, there was an increase in t

... Show More
View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Thu Mar 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Low Carbon Steel in Sulfuric Acid Using Polyvinyl Alcohol
...Show More Authors

The inhibitive power of Polyvinyl Alcohol (PVA) was investigated toward the corrosion of carbon steel in 0.2N H2SO4 solution in the temperature range of 30-60˚C and PVA concentration range of 150-2000 ppm.

   The corrosion rate was measured using both the weight loss and the electrochemical techniques. The weight loss results showed that PVA could serve as a corrosion inhibitor but its inhibition power was found to be low for the corrosion of carbon steel in the acidic media. Electrochemical analysis of the corrosion process of carbon steel in an electrochemical corrosion cell was investigated using 3-Electrode corrosion cell. Polarization technique was used for carbon steel corrosion in 0.2N H

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 15 2017
Journal Name
School Of Engineering
Development of novel demountable shear connectors for precast steel-concrete composite bridges
...Show More Authors

Two novel demountable shear connectors for precast steel-concrete composite bridges are presented. The connectors use high-strength steel bolts, which are fastened to the steel beam with the aid of a special locking configuration that prevents slip of bolts within their holes. Moreover, the connectors promote accelerated construction and overcome typical construction tolerances issues of precast structures. Most importantly, the connectors allow bridge disassembly, and therefore, can address different bridge deterioration scenarios with minimum disturbance to traffic flow, i.e. (1) precast deck panels can be rapidly uplifted and replaced; (2) connectors can be rapidly removed and replaced; and (3) steel beams can be replaced, while precast

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Mild Steel by Curcuma Extract in Petroleum Refinery Wastewater
...Show More Authors

The inhibitor property of curcuma longa L. extract in different concentrations of simulated refinery wastewater (0.05% - 2% wt) and at various temperatures (30, 35 and 40 ˚C) was investigated using weight loss method. The results showed that the presence of about 1.2 % (v/v) of curcuma extract gave about 84% inhibition indicating its effectiveness on mild steel corrosion in simulated refinery wastewater, besides the adsorption process on the mild steal surface obeyed the Langmuir adsorption isotherm.

View Publication Preview PDF
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Mass Transfer Coefficient During Cathodic Protection of Low Carbon Steel in Seawater
...Show More Authors

The aim of this research is to calculate mass transfer coefficient, kd, during cathodic protection of low carbon steel in neutral seawater (3.5% W/V NaCl in distilled water with pH = 7). Two types of cathodic protection were used:

First: Sacrificial anode cathodic protection (SACP) were a pipeline of steel carrying seawater  using zinc as a sacrificial anode and with variable temperatures ranged (0 – 45oC) and volumetric flow rate ranged (5 – 900 lit/hr). It was found that the kd increases with increasing temperature and volumetric flow rate of seawater, where kd ranged (0.24×10-6 – 41.6×10-6 m/s).

Second: Impressed current cathodic pr

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 01 2026
Journal Name
Civil Engineering Journal
AI-Driven Shear Capacity Model of Steel Studs in Composite Structural Systems
...Show More Authors

In composite steel-concrete structures, shear connectors in the form of headed steel studs are commonly utilized to transfer longitudinal shear force developed at the interface between the two materials. To overcome the shortcomings of design codes, which frequently understate shear capacity and fail to take advantage of sophisticated computational methods, this paper presents an optimization attempt to estimate the shear strength of headed steel studs utilizing the Grey Wolf Optimizer (GWO) technique using MATLAB software. Data from 234 experimental tests are employed to identify and highlight key input parameters influencing the shear strength of headed steel studs. These key parameters include concrete compressive strength (f’c

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Minimal sternotomy surgery in comparison to standard sternotomy in the coronary bypass Surgery
...Show More Authors

Background Median sternotomy is the gold standard incision for most cardiac operations. However, with the advent of minimal invasive surgery, a new approach emerged in cardiac surgery named mini-sternotomy and has been successfully used to perform a variety of operations.

 The aim of this paper is to present our experience of using mini-sternotomy to harvest the left internal mammary artery (LIMA) for off-pump revascularization of the left anterior descending artery (LAD)

 Methodology Over a 2-year period (October 2012-October 2014), 100 patients underwent coronary artery bypass grafting (CABG) via conventional median sternotomy (CMS) (n=80) and mini-sternotomy (MS) (n=20). The

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
2019 First International Conference Of Computer And Applied Sciences (cas)
A Comparison for Some of the estimation methods of the Parallel Stress-Strength model In the case of Inverse Rayleigh Distribution
...Show More Authors

View Publication
Scopus (10)
Crossref (3)
Scopus Crossref
Publication Date
Thu Apr 21 2022
Journal Name
Neuroquantology
New Record of the Species Margarinotus punctiventer, Marseul, 1854 (Histeridae, Coleoptera) with Forensic Study from Sulaymaniyah, City Iraq.
...Show More Authors