Preferred Language
Articles
/
jbcd-2550
Development of Sinusitis After Sinus Floor Elevation Surgery: A Systematic Review
...Show More Authors

Background: Maxillary sinusitis can arise after sinus floor elevation surgery and should be treated immediately to prevent further complications which included dental implants failure, graft lost, and oro-antral fistula. This is the first systematic review to assess the incidence, causes, and treatment of sinusitis after sinus lift surgery. Materials and methods: An electronic search included MEDLINE (PUBMED) data base site was carried out for articles involving development of sinusitis after sinus lift surgery from September 1997 up to April, 8, 2017. The search was done and reviewed by two independent authors. Results: The total results of electronic search were (182) abstracts and articles, the extracted articles which involved development of sinusitis after sinus lift surgery were (25) studies. Of the 25 articles only (8) articles fit the inclusion criteria. Maxillary sinusitis was calculated for all selected studies and it was ranged from 2.12% to 12.7% with average of 5.4 %. Conclusion: Maxillary sinusitis could be developed after sinus lift surgery with average of 5.4 % and the patients with previous maxillary sinus disease showed to be at increased risk of sinusitis after sinus lift surgery.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Al-khwarizmi Engineering Journal
Effect of Environmental Factors on the Accuracy of a Quality Inspection System Based on Transfer Learning
...Show More Authors

In this research, a study is introduced on the effect of several environmental factors on the performance of an already constructed quality inspection system, which was designed using a transfer learning approach based on convolutional neural networks. The system comprised two sets of layers, transferred layers set from an already trained model (DenseNet121) and a custom classification layers set. It was designed to discriminate between damaged and undamaged helical gears according to the configuration of the gear regardless to its dimensions, and the model showed good performance discriminating between the two products at ideal conditions of high-resolution images. So, this study aimed at testing the system performance at poo

... Show More
Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
A Study of the Structural and Optical Properties of SnS:F prepared by chemical spray pyrolysis technique
...Show More Authors

Thin films of pure tin mono-sulfide SnS and tin mono-sulfide for (1,2,3,4)% fluorine SnS:F with Thicknesses of (0.85 ±0.05) ?m and (0.45±0.05) ?m respectively were prepared by chemical spray pyrolysis technique. the effect of doping of F on structural and optical properties has been studied. X-Ray diffraction analysis showed that the prepared films were polycrystalline with orthorhombic structure. It was found that doping increased the intensity of diffraction peaks. Optical properties of all samples were studied by recording the absorption and transmission spectrum in range of wave lengths (300-900) nm. The optical energy gap for direct forbidden transi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
A comparison study of the Structural and magnetic properties of pure Ni metal and NiZnMn ferrite
...Show More Authors

The magnetic properties of a pure Nickel metal and Nickel-Zinc-Manganese ferrites having the chemical formula Ni0.1(Zn0.4Mn0.6)0.9Fe2O4 were studied. The phase formation and crystal structure was studied by using x-ray diffraction which confirmed the formation of pure single spinel cubic phase with space group (Fd3m) in the ferrite. The samples microstructure was studied with scanning electron microstructure and EDX. The magnetic properties of the ferrite and nickel metal were characterized by using a laboratory setup with a magnetic field in the range from 0-500 G. The ferrite showed perfect soft spinel phase behavior while the nickel sample showed higher magnetic loss an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
International Journal Of Data Analysis Techniques And Strategies
A class of efficient and modified testimators for the mean of normal distribution using complete data
...Show More Authors

View Publication
Scopus (9)
Crossref (2)
Scopus Crossref
Publication Date
Fri Aug 06 2021
Journal Name
Research Journal Of Pharmacy And Technology
Molecular Detection and Genotyping of Human Herpes Virus 8 in a sample of Iraqi Blood Donors
...Show More Authors

Human herpes virus-8 (HHV-8) infection has increased recently in Arabic countries. HHV-8 in healthy persons does not necessarily cause life-threatening infection, and however, it causes a more severe infection among immunocompromised patients. The distribution of HHV-8 genotypes varies according to ethnicity and depends on the geographic region prior rapid development of global travel. A cross sectional prospective study included a hundred healthy blood donor samples with a mean age of (36.60±10.381), 81% were positive for molecular detection of HHV-8 DNA. PCR results for HHV-8 were strongly related with risk factors such as the number of sexual relations, previous surgeries, blood transfusion, dental operation, and the number of b

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Ingénierie Des Systèmes D Information
Performance Evaluation of a Multi Organizations Secure Internet of Vehicles Based on Hyperledger Fabric Blockchain Platform
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Radiological Assessment of Mandibular Retromolar Canal (MRMC) Using CBCT-Radiographs in a Sample of Iraqi Patients
...Show More Authors

Background: Because of its clinical and surgical importance and lack of precise information about this rare and important anatomical landmark, this study was designed to detect the presence, configurations and length of Mandibular Retromolar Canal (MRMC) with aid of CBCT visualization. Materials and methods: In this retrospective study the data was obtained from Specialist Health Center in AL-Sadder city in Baghdad for (100) patients with 200 inferior dental canal, all of them referred to CBCT scan (Kodak 9500, French origin). The scanning was done with tube voltage 90 kVp, tube current with 10mA and exposure time was 10 s., the field of view was measured with 5cm x 3.7cmwith 0.03mm voxel size Results: In the present study the prevalence of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Mar 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study of Absorption Column with Single Bubble Cap Tray in the Production of Sodium Bicarbonate
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Physical Mesomechanics Of Condensed Matter: Physical Principles Of Multiscale Structure Formation And The Mechanisms Of Nonlinear Behavior: Meso2022
Calculation of radon gas concentrations in administration rooms for a number of schools in Diyala governorate
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Nov 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental arches symmetry in a sample of Iraqi children at the mixed dentition stage
...Show More Authors

Background: Little is known about asymmetry of children's dental arches, the purpose of this study was to verify the presence of asymmetry of dental arches among Iraqi children in the mixed dentition stage. Materials and methods: The sample included 52 pairs of dental casts, 27 pairs belong to males and 25 pairs for females. Three linear distances were utilized on each side on the dental arch: Incisal-canine distance, canine-molar distance and incisal-molar distance, which represent the dental arch segmental measurements using the digital sliding calipers, which is accurate up to 0.02 mm. Results: No significant sides' differences with high correlation coefficient were found between the right and left incisal-canine, canine-molar and in

... Show More
View Publication Preview PDF