Background: The marginal adaptation has a key role in the success and longevity of the fixed dental restoration, which is affected by the impression and the fabrication techniques .The objective of this in vitro study was to evaluate and compare the marginal fitness of lithium disilicate crowns using two different digital impression techniques (direct and indirect techniques) and two different fabrication techniques (CAD/CAM and Press techniques). Materials and Methods: Thirty two sound upper first premolar teeth of comparable size extracted for orthodontic reason were selected in this study .Standardized preparation of all teeth samples were carried out with modified dental surveyor to receive all ceramic crown restoration with 1 mm deep chamfer finishing line, 4 mm axial length and 6 degree convergence angle. Half of the teeth were duplicated and poured in type IV dental stone to have sixteen dies and then these dies and the remaining teeth divided in to two groups according to the type of digital impression techniques (n=16) as follow: Group A: Indirect digital impression technique scanned by inEos X5 camera; Group B: Direct digital impression technique scanned by CEREC AC Omnicam camera. Each group was subdivided according to the technique of fabrication into two subgroups (n=8): Press technique using IPS e-max press (A1, B1); CAD/CAM technique using IPS e-max CAD (A2, B2).Marginal gaps were evaluated on the prepared teeth at four defined points on each aspect using digital microscope at a magnification of (280X). One way ANOVA and LSD tests were used to identify and localize the source of difference among the groups. Results: The results showed that indirect digital impression with IPS e-max CAD/CAM group A2 revealed the poorest marginal integrity with (55.93 μm ± 3.300). Group B2 and group A1 were next in line with(44.49 μm ± 6.840 and 37.74 μm± 5.433) respectively, while in the first group of restorations, the result of 29.9 μm ± 5.534 obtained with direct digital impression with pressable ceramic was clearly better. Conclusions: All the tested digital impression techniques showed clinically acceptable accuracy and intraoral scanning with pressable ceramic significantly enhanced the marginal fit
Dyes are extensively water-soluble and toxic chemicals. The disposing of wastewater rich with such chemicals has severely impacted surface water quality (rivers and lakes). In the current study, an anionic dye, methyl orange, were extracted from wastewater fluids using bulk liquid membranes supplemented with an anionic carrier (Aliquat 336 (QCI)). Parameters including solvent type (carbon tetrachloride and chloroform), membrane stirring speed (100-250 rpm), mixing speed of both phases (50-100 rpm), The feed pH (2-12) and implemented temperature (35-60 °C) were thoroughly analyzed to determine the effect of such variables on extraction effectiveness. Furthermore, the effect of methyl orange (10-50 ppm) in the feed stage and NaOH (0
... Show MoreA novel demountable shear connector for precast steel-concrete composite bridges is presented. The connector uses high-strength steel bolts, which are fastened to the top flange of the steel beam with the aid of a special locking nut configuration that prevents bolts from slipping within their holes. Moreover, the connector promotes accelerated construction and overcomes the typical construction tolerance issues of precast structures. Most importantly, the connector allows bridge disassembly. Therefore, it can address different bridge deterioration scenarios with minimum disturbance to traffic flow including the following: (1) precast deck panels can be rapidly uplifted and replaced; (2) connectors can be rapidly removed and replaced; and (
... Show MoreA new Ni(II) nanostructured chelating system (DHN) was introduced for selective optical heavy-metal ion sensing in an aqueous medium. The cooperative chelating system comprising 8-hydroxyquinoline (8-HQ) and dimethylglyoxime (DMG) has been developed for the first time in association with fibre optic sensing for selective optical heavy-metal ion sensing in an aqueous medium. The Ni(II) nanocompound fluoresces upon 578 nm excitation, showing a highly sensitive optical response with a linear calibration curve in the range 0–100 ng/mL. The regression equation of the calibration curve is y = 0.0035x + 0.9990, which indicates very good linearity, implying R2 = 0.999 with high sensitivity (calibration slope of 0.0035) and low baseline noise (bla
... Show MoreThe temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show MoreThe conservation for biodiversity in Iraqi freshwater environments is important to protecting native species from the environmental impacts of alien species. Clarias gariepinus (Burchell, 1822) (Siluriformes, Clariidae) has been recognized as an alien species in Iraqi water bodies. This study aims to use molecular DNA to identify this catfish and trace its origins using. The DNA sequences of C. gariepinus were done using the mitochondrial DNA cytochrome c oxidase subunit 1 (COI) gene, and a specific primer set. The polymerase chain reaction (PCR) amplification was used to align the COI gene as a barcoding marker. After analysis, the sequences were compared with sequences in the National Center for Biology Information (NCBI) database
... Show More