Preferred Language
Articles
/
jbcd-194
Evaluation of the effect of addition of polyester fiber on some mechanical properties of heat cure acrylic resin
...Show More Authors

Background: This study aimed to evaluate the effect addition of polyester fibers on the some mechanical properties of heat cured acrylic resin (implant strength, flexural strength and hardness) Materials and methods: Ninety specimens were used in the study. Thirty specimens were used for impact strength measurements (80mm X 10mm X 4mm) length, width and thickness respectively. The specimens divided into three test groups (n=10), first group formed from heat cure acrylic resin without fiber reinforcement. Second group was formed from heat cure acrylic resin was reinforced with 2 mm length polyester fiber and third group was formed from heat cure acrylic resin reinforced with 4mm length polyester fiber, impact strength measured by impact testing device. 30 specimens with (65 mm X 10mm 2.5mm) length, width and thickness respectively were used in 3 groups (n=10) flexural strength test. The flexural strength was measured by using flexural testing device. 30 specimens with (65mm X 10m X 2.5mm) length width and thickness respectively were used for hardness test. The specimens were divided into 3 group (n=10) as in impact strength and flexural strength. Hardness measured by using (shore D hardness tester TH210). Results: revealed statistically significant increase on impact strength especially on 4mm length when compared to control group. Significant decreases in flexural strength of PMMP. When compared to control group with 4mm length fiber reinforcement. Non significant decrease when compared control group with 2mm length fiber reinforced PMMA. Significant decrease in hardness of PMMA resin after reinforcement with 2mm, 4mm lengths polyester fibers. Conclusions: Strengthening with the polyester fiber decreased the flexural strength and hardness of the resin, but increased impact strength. Thus when high impact acrylic resins are needed, fiber reinforced resins may be the material of choice.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Kirkuk University Journal For Agricultural Sciences
THE IMPORTANCE OF HAVING SOME BASIC COMPETENCIES AMONG WORKERS IN DIGITAL AGRICULTURAL EXTENSION FROM THE POINT OF VIEW OF SENIOR MANAGEMENT, MIDDLE MANAGEMENT AND HIGHER DEGREE HOLDERS
...Show More Authors

The research aims to identify the availability of some basic competencies that are required to be available to workers in digital agricultural Extension from the point of view of senior management, middle management, and, employees with Post-graduate education degrees, represented by the following: Transition to digital agricultural Extension for sustainable and smart family farms, benefiting from international expertise and experiences in applying for Digital agricultural Extension, preparing and implementing Extension messages through platforms, factors affecting the effectiveness of digital agricultural Extension and its platforms, following up and evaluating the activities and programs of the digital Extension platform. The research pop

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 02 2025
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Morphometric Evaluation of Lips in Iraqi Subjects with its Possible Esthetic Benefits
...Show More Authors

Objectives: to assess the normal range of different lip parameters with gender difference and its role in esthetic procedures for Iraqi people. Methods: direct lip measurements were performed with closed lip position using a digital vernier caliper in 132 young Iraqi subjects (89 female and 43 male). Results: Lip measurements showed sexual dimorphism with higher value in men than women in six parameters. Cutaneous height of the upper lip was higher in both sexes. The mustache area in males was longer in males compared to females.  Also, it was noticed that upper lip vertical thickness had a higher value, especially in subjects with cosmetic procedures. In addition to that, vertical upper lip thickness showed a higher rise in values

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Sep 22 2016
Journal Name
Applied Sciences
Analysis and Evaluation of Performance Gains and Tradeoffs for Massive MIMO Systems
...Show More Authors

View Publication
Scopus (16)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Jan 10 2012
Journal Name
Iraqi Journal Of Community Medicine
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
...Show More Authors

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages rang

... Show More
Publication Date
Fri Oct 01 2010
Journal Name
Saudi Pharmaceutical Journal
Comparative clinical evaluation of ketotifen and montelukast sodium in asthmatic Iraqi patients
...Show More Authors

View Publication
Scopus (8)
Crossref (3)
Scopus Crossref
Publication Date
Sun Feb 22 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Sonographic evaluation of masseter muscle thickness in bruxist and non-bruxist subjects
...Show More Authors

Background: Masseter muscle is a jaw closing muscle of the mandible involved in Para functional habits; which include lip and cheek chewing, fingernail biting, and teeth clenching or bruxism which can be classified as awake or sleep bruxism. Patients with sleep bruxism are three to four times more likely to experience jaw pain and limitation of movement than people who do not experience sleep bruxism. The aim of this study is to measure the thickness of the masseter muscle in bruxist subjects and compare it with non-bruxist subjects by using sonography. Materials and Method: Forty Iraqi subjects with age ranged (20-40) divided into two groups according to the presence of bruxism. Clinical examination was made and masseter muscle thickness

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Evaluation Yield of Okra with Associated Traits Using Analysis Correlation and Path
...Show More Authors
Abstract<p>The study was conducted at the fields of the Department of Horticulture and Landscape Gardening, College of Agriculture Engineering Sciences, University of Baghdad. During the spring 2017. All the recommended practices were followed during experimentation. The experimental material consisted four Genotype it is Batraa, Btera, Mosulle, and local selection. The experiment was applied in Randomized Complete Block Design (RCBD). The objectives of Study were to estimate the some genetic parameters and path coefficient for some traits Okra, The results of statistical analysis for these genotypes were highly significant differences for all traits except the traits number of leaves, the numbe</p> ... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jul 01 2013
Journal Name
Optics & Laser Technology
Evaluation of PMMA joining to stainless steel 304 using pulsed Nd:YAG laser
...Show More Authors

This paper reports an experimental study of welding of dissimilar materials between transparent Polymethylmethacrylate (PMMA) and stainless steel 304 sheets using a pulsed mode Nd:YAG laser. The process was carried out for two cases; laser transmission joining (LTJ) and conduction joining (CJ). The former is achieved when the joint is irradiated from the polymer side and the latter when the joint is irradiated from the opposite side (metal side). The light and process parameters represented by the peak power (Pp), pulse duration (τ), pulse repetition rate (PRR), scanning speed (ν) and pulse shape have a significant effect on the joint strength (Fb), joint bead width (b), joint quality and appearance. The optimum parameters were determined

... Show More
View Publication
Scopus (79)
Crossref (71)
Scopus Clarivate Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Mandibular Third Molar Position by Using Space-Width Ratio Method
...Show More Authors

Background: The prediction of changes in the mandibular third molar position and eruption is an important clinical concern because third molar retention may be beneficial for orthodontic anchorage. The aims of this study were to assess the mandibular third molar position by using medical CT scan and lateral reconstructed radiograph and evaluate gender differences. Materials and Methods: The sample of present study consisted of 39 patients (18 males and 21 females) with age range 11-15 years who were attending at Al-Suwayra General Hospital/ the Computerized Tomography department. The distance from anterior edge of ramus to distal surface of permanent mandibular second molar and mesio-distal width of developing mandibular third molar were

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 10 2022
Journal Name
Oral Surgery
Evaluation of buffered local anaesthesia in dental extraction: A randomized controlled study
...Show More Authors

Buffering of Local anaesthesia (LA) has been suggested as a mechanism to improve injection comfort and hasten the onset of anaesthesia. Aim This study aimed to evaluate the effectiveness of buffered LA in the extraction of maxillary premolars and molars. Materials and Methods This randomized controlled study included 100 patients who were indicated for extraction of maxillary posterior teeth, they were randomly divided into two groups; a study group that received infiltration of buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA, and a control group that received non-buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA. The buffering was performed using the Onset® LA buffering system (Onpharma®). The outcome va

... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Crossref