Preferred Language
Articles
/
1BeUX5MBVTCNdQwCetKO
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
...Show More Authors

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages ranging between (16- 82) and is divided between 29 people from healthy people (I) which contain (13 males and 16 females) ages ranging between (16- 82) and a standard deviation of 22.6. Twenty nine of patients with mitral valve stenosis were divided into group (II) contains (6 males and 8 females) ages ranging between (28-76) and the standard deviation of 17.8, group (III) contains (5 males and 4 females) ages ranging between (40-71) and the standard deviation of 16.1 and group (IV) contain (3 male and 3 female) ages ranging between (56-72) and the standard deviation of 17.9. Studying changes developments in physical factors resulting from mitral valve stenosis and depending on these factors were calculated to change the resistance and conductivity and studying the relationship of the change in area and the change of physical factors. Results: The flow rate and area of mitral valve was significantly less in group IV than other groups, but pressure gradient, max velocity, pressure half time, max pressure were higher and more significantly in group IV. Resistance is significantly increases and it is higher in group IV compared with other groups. Conductance is higher in group I but more significant in group II. Conclusion: There is a strong correlation between the pressure half time and area of mitral valve. Resistance was significantly increased and it is higher in sever mitral stenosis. Conductance is high in mild mitral stenosis. The increase in mitral pressure gradient is frequently compensated by a decreased conductance. Age was highly influential but sex exerts less influence to change the physical parameters.

Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Medicinal And Chemical Sciences
Echocardiographic Assessment of the Aortic Stenosis Valve Area: Parameters and Outcome
...Show More Authors

Background: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.

Scopus (10)
Scopus
Publication Date
Tue Jun 30 2009
Journal Name
Al-kindy College Medical Journal
Carotid Intima-Media Thickness in Rheumatoid Arthritis Detected by Doppler Ultrasound
...Show More Authors

Background: The excess mortality associated with
rheumatoid arthritis is largely due to
cardiovascular disease. Rheumatoid arthritis is of
primary importance in atherogenesis. The intimamedia thickness of extracranial carotid arteries is a
measurable index of the presence of
atherosclerosis.
Objective: To assess carotid intima-media
thickness in rheumatoid arthritis by Doppler
ultrasound.
Methods: Fifty two Iraqi patients with rheumatoid
arthritis were studied and compared with another
fifty two, healthy individuals matched for age and
sex as a control group. Full history was taken and
complete clinical examination was done for all
individuals in both groups. Rheumatoid arthritis
diagnosis was

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Mitral Valve Prolapse In Patients With Benign Joint Hypermobility Syndrome (BJHS)
...Show More Authors

Background: Joint hypermobility  was first mentioned by Hippocrates as an isolated feature, when he described the Celts' Incapacity to Pull a Bowstring or Throw a Dart, Due to The Slackness of Their Limbs

Objective: to determine the prevalence of mitral valve prolapse(MVP)in patients with benign hypermobility syndrome (BJHS).

Type of the study: Cross –sectional study.

Methods: Ninety patients with BJHS were included in this study. Full cardiological assessment was done for all of them,  which  include clinical examination, electrocardiography and echocardiography. Cardiac assessment was done for another sixty age and sex matched (

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Iraqi Journal Of Science
Evaluation of the Physical Parameters on Ischemic Heart Disease Patients Using Echocardiography
...Show More Authors

      Background: Left ventricular function and volumes have major diagnostic and prognostic importance in patients with various cardiac diseases, such as ischemic heart disease which is a life-threatening heart disease condition characterized by systolic dysfunction and a decrease in cardiac output. 

According to left ventricular ejection fraction, the degree of ischemic heart disease was classified as mild, moderate, and severe. To determine cardiac function and hemodynamics, the echocardiography technique is used, which is a noninvasive diagnostic method.

Patients and Methods: The study included 216 patients between 25 and 75 years old; 121 males and 95 females; 265 normal individuals (age range: 25 to 75 years ol

... Show More
View Publication Preview PDF
Scopus (6)
Scopus Crossref
Publication Date
Fri Jan 24 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The value of ultrasound and color Doppler ultrasonography in the evaluation of periapical lesions in comparison to histopathological and/or surgical findings
...Show More Authors

Background: Imaging techniques play a very important role in the specialty of endodontic. The ultrasonographic technique is non-expensive procedure, safe, and reproducible. The aim of the study was to determine the sensitivity, specificity, and accuracy of ultrasound and color Doppler ultrasonography in evaluation of periapical lesions (cyst, granuloma, mixed lesion “cyst within graulomas mass”, and abscess. Subject, Material and method: The sample consists of prospective study for 64 Iraqi participants who attended Karbalaa Specialized Center for Dentistry (males & females). Those patients were diagnosed clinically and radiographically as having periapical lesions of dental origin. They were examined by real time ultrasound and color

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Serbian Journal Of Experimental And Clinical Research
Role of Combining Colour Doppler and Grey Scale Ultrasound in Differentiating Benign from Malignant Ovarian Masses
...Show More Authors
Abstract<p>The aim of this study was to evaluate ovarian masses with conventional grey scale ultrasonography and colour Doppler flow imaging and to assess the diagnostic reliability of these methods in differentiating benign and malignant ovarian masses.</p><p>We assessed 56 patients with an ovarian mass. Morphological characterisation of the mass was performed utilising the Sassone score. Colour Doppler parameters were recorded for each patient, and the Caruso vascular score was also applied. The results were compared with surgical/pathological and/or follow-up scans.</p><p>Using the Sassone score, overall reliability in differentiating ovaria</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis and evaluation of B-cyclodextrin Based Nanosponges of 5- Fluorouracil by Using Ultrasound Assisted Method
...Show More Authors

 

CD-nanosponges were prepared by crosslinking B-CD with diphenylcarbonate (DPC) using ultrasound assisted technique. 5-FU was incorporated with NS by freeze drying, and the phase solubility study, complexation efficiency (CE) entrapment efficiency were performed. Also, the particle morphology was studied using SEM and AFM. The in-vitro release of 5-FU from the prepared nanosponges was carried out in 0.1N HCl.

5-FU nanosponges particle size was in the nano size. The optimum formula showed a particle size of (405.46±30) nm, with a polydispersity index (PDI) (0.328±0.002) and a negative zeta potential (-18.75±1.8). Also the drug entrapment efficiency varied with the CD: DPC molar ratio from 15.6 % to 30%. The SEM an

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (5)
Scopus Crossref
Publication Date
Fri Sep 21 2012
Journal Name
Open Journal Of Obstetrics And Gynecology
Evaluation of thalamus echogenicity by ultrasound as a marker of fetal lung maturity
...Show More Authors

View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Dec 25 2015
Journal Name
مجلة اتحاد الجامعات العربية للدراسات والبحوث الهندسية
Smart Sensing for Variable Pressure of Oil Well Safety Valve Using Proportional Pressure Control valve
...Show More Authors

Protection of the oil pipelineswhich extracted from the wells was found to shut the well and prevent the leakage of oil when broken using safety valve. This valve is automatically activated by loss of pressure between the well and pipelines, which take the pressure, signal from hydraulic pressure sensor through pressure control valve which has constant or variable value but it is regulated manually. The manual regulatory process requires the presence of monitoring workers continuously near the wells which are always found in remote areas. In this paper, a smart system has been proposed that work with proportional pressure control valve and also electronic pressure sensor through Arduino controller, which is programmed in a way that satisfie

... Show More
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Variable Parameters on Carbon Residue of Iraqi Vacuum Gas Oil using Ultrasound Techniques
...Show More Authors

An ultrasonic treatment was applied to the vacuum gas oil at intervals of 5 to 30 minutes, at 70°C.  In this work, the improvement of the important properties of Iraqi vacuum gas oil, such as carbon residue, was studied with several parameter conditions that affect vacuum efficiency, such as sonication time (5, 10, 15, 20, 25, and 30) min, power amplitude (10–50%). After ultrasonic treatment, the carbon residue of vacuum gas oil was evaluated using a Conradson carbon residue meter (ASTM D189). The experiment revealed that the oil's carbon residue had decreased by 16%. As a consequence of the experiment It was discovered that ultrasonic treatment might reduce the carbon residual and density of oil samples being studied. It also notice

... Show More
View Publication Preview PDF
Crossref