ABSTRACT Background: One of the challenges to use chlorhexidine is its effect on the amount of microleakage after restoration; however, use of the materials with antibacterial properties after tooth preparation and before restoration has been widespread. The objective of this, in-vitro, study was to evaluate the influence of consepsis (chlorhexidine gloconate disinfectant) application on microleakage in class II cavities restored with light cured composite using universal adhesive system; etch and rinse technique –self etch technique. Materials and Methods: Forty class II cavities were prepared on mesial and distal surfaces of 20 non-carious mandibular third molars. The cavities were divided into four groups; (n =10 for each group). G1: cavities were bonded with (single bond universal adhesive, 3MESPE) after etching with 35% phosphoric acid - etch and rinse technique, without chlorhexidine , G2: chlorhexidine was used after etching with 35% phosphoric acid, then cavities were bonded with (single bond universal adhesive, 3MESPE) - etch and rinse technique . G3: cavities were bonded with (single bond universal adhesive, 3MESPE) - self etch technique, without chlorhexidine, G4: The chlorhexidine was used before bonding. All groups were restored with non – hybrid composite resin (Z 350, 3MESPE). Micrlerackage was evaluated at gingival margin using methylene blue dye penetration method. In each cavity the dye penetration in millimeters was measured by strereomicroscope. Statistical analysis for the data was carried out using one-way ANOVA and LSD test. Results: Group G2 produced the least microleakage which is statistically highly significantly different than the remaining groups. Group G3 produced the highest microleakage which is statistically high significant difference than G1 and G2, but the difference is not significant with group G4. Conclusions: Consepsis can be used as cavity disinfectants when restoring the cavities with single bond universal adhesive as etch and rinse technique. However, its effect seems to be lower when using the single bond universal adhesive as self-etch technique.
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreRecently, there has been a notable surge in interest surrounding entrepreneurial orientation and strategic entrepreneurship. These concepts are particularly relevant due to their modern characteristics that aid in adapting to the environment. They also play a crucial role in improving production, service, and technological processes to sustain value, minimize competition, and drive ongoing enhancements, ultimately leading to a position of leadership within public companies. Therefore, the primary focus of this research was to examine the influence of entrepreneurial orientation on achieving strategic entrepreneurship. This influence is further mediated by the presence Iraqi Ministry of Agric
... Show Moreتعد لعبة كرة السلة من الألعاب الرياضية التي تحتاج متطلبات بدنية ووظيفية خاصة بها، وذلك من خلال الانتقال داخل الملعب بالكرة أو بدونها والسبل للتخلص من ملاحقة الخصم أثناء الدفاع وكيفية المناورة أثناء الهجوم مع إجادة التصويب بكافة أنواعه داخل الملعب، ومن هنا تكونت مشكلة البحث في كيفية تطوير تلك العوامل الوظيفية والتي لها الأثر في الارتقاء بمستوى أداء اللاعب أثناء اللعب، وعن طريق استخدام الباحثان لطريقة جهاز ا
... Show MoreBackground: Speckle tracking echocardiography (STE)-derived mitral annular displacement (MAD) utilizes the speckle tracking technique to measure strain vectors, which provides accurate estimates of left ventricular ejection fraction (LVEF).Objectives: To validate the accuracy of mitral annular displacement (MAD), assessed by Speckle Tracking Echocardiography (STE), as a surrogate for determination of left ventricular systolic function in comparison to 2-Dimensions Simpson method in patients with different heart diseases.Methods : This cross-sectional study included patients who referred to outpatient department of Ibn Albitar Center for Cardiac Surgery, Baghdad, Iraq, between October 2012 and April 2013. STE continuously tracked annular
... Show MorePultruded materials made of Fiber-Reinforced Polymer (FRP) come in a broad range of shapes, such as bars, I-sections, C-sections, etc. FRP materials are starting to compete with steel as structural materials owing to their great resistance, low self-weight, and cheap maintenance costs, especially in corrosive conditions. This study aims to evaluate the effectiveness of a novel concrete Composite Column (CC) using Encased I-Section (EIS) as a reinforcement in contrast to traditional steel bars by using Glass Fiber-Reinforced Polymer (GFRP) as I-section (CC-EIS) to evaluate the effectiveness of the hybrid columns which have been built by combining GFRP profiles with concrete columns. To achieve the aims of this study, nine circular co
... Show MoreThe title compound, [Ru(C12H7Br2N2)2(CO)2], possesses a distorted octahedral environment about the Ru atom, with two cyclometallated 4,4′-dibromoazobenzene ligands and two mutually cis carbonyl ligands. The donor atoms are arranged such that the N atoms are mutually trans and the aryl C atoms are trans to carbonyl ligands.
Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randoml
... Show More