Preferred Language
Articles
/
jbcd-165
The effect of addition of untreated and oxygen plasma treated polypropylene fibers on some properties of heat cured acrylic resin
...Show More Authors

Background: The polymethyl methacrylate is the most reliable material for the construction of complete and partial dentures, despite satisfying esthetic demand itsuffered from having unsatisfactory properties like impact strength and transverse strength. This study was designed to improve the impact strength and transverse strength of heat cure acrylic resin by adding untreated and oxygen plasma treated polypropylene fibers and investigate the effect of this additive on some properties of acrylic resin materials. Materials and methods: Untreated and oxygen plasma treated polypropylene fibers was added to PMMA powder by weight 2.5 %. Specimens were constructed and divided into 5 groups according to the using tests; each group was subdivided in to 3 subgroups. The tests conducted were impact strength, transverse strength, surface hardness, surface roughness, water sorption and solubility. Data were analyzed by one way analysis of variance (ANOVA) and least significant differences (LSD). Results: After incorporation of untreated and oxygen plasma treated polypropylene fibers there was a highly significant increase in impact strength and surface hardness; while there was a non significant difference in transverse strength. Also the value of water sorption increase significantly but with the limit of ADA specification. Conclusion:Within the limit of this study it can be concluded that the reinforcement with polypropylene fibers effective method to increase fracture resistance of denture base; while reinforcement with oxygen plasma treated polypropylene fibers further increase fracture resistance.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Removal of Cu2+, Pb2+ , And Ni 2+ Ions From Simulated Waste Water By Ion Exchange Method On Zeolite And Purolite C105 Resin
...Show More Authors

The removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Fri Mar 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the correlation between the tensile and diametrical compression strengths of 3D-printed denture base resin reinforced with ZrO2 nanoparticles
...Show More Authors

Background: The mechanical properties of 3D-printed denture base resins are crucial factors for determining the quality and performance of dentures inside a patient’s mouth. Tensile strength and diametral compressive strength are two properties that could play significant roles in assessing the suitability of a material. Although they measure different aspects of material behavior, a conceptual link exists between them in terms of overall material strength and resilience. Aim: This study aims to investigate the correlation between tensile strength and diametral compressive strength after incorporating 2% ZrO2 nanoparticles (NPs) by weight into 3D-printed denture base resin. Methods: A total of 40 specimens (20 dumbbell-shaped and

... Show More
Scopus (10)
Crossref (5)
Scopus Crossref
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Engineering
The Effect of Recycled Heating and Cooling and The Effect of The Speciment Size on The Compressive Strength of Concrete Exposed To High Temperature
...Show More Authors

     In the present work effect of recycled heating and cooling on the values of concrete compressive strength due to high temperature of 4000C was studied.

    The tests show that the percent of reduction in compressive strength of the samples which exposed to a temperature of 4000C for one cycle was 32.5%, while the reduction was 52.7% for the samples which were exposed to recycled heating and cooling of ten times .      

   Moreover a study of the effect of specimen sizes on the percentages of compressive strength reduction due to high temperature

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
The effect of compound exercises in developing front and back stroke skills and some physiological indicators of badminton juniors
...Show More Authors

The accuracy of the skillful performance of the front and back dimensions of badminton in volleyball, occurs through the investment of complex exercises (physical skills) in a single performance and its characteristics that give the correct movement behavior and speed to the accuracy of the performance of the strokes as well as the identification of changes in some physiological indicators of By using these compound exercises. The research problem lies: I found a weakness in the accuracy of the performance of the front and back dimensions strike and diagnosed this through the tests that it conducted on the players to identify and know the problem, and attributed this weakness to a weakness in the necessary physical and skill abilities and t

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 14 2014
Journal Name
Arabian Journal Of Geosciences
Wetting and drying collapse behaviour of collapsible gypseous soils treated by grouting
...Show More Authors

View Publication
Crossref (39)
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Rheological Properties of Non-Newtonian Fluids under the Effect of temperature Using Different Chemical Additives
...Show More Authors

   This research studies the rheological properties ( plastic viscosity, yield point and apparent viscosity) of Non-Newtonian fluids under the effect of temperature using different chemical additives, such as (xanthan gum (xc-polymer), carboxyl methyl cellulose ( High and low viscosity ) ,polyacrylamide, polyvinyl alcohol, starch, Quebracho and Chrome Lignosulfonate). The samples were prepared by mixing 22.5g of bentonite with 350 ml of water and adding the additives in four different concentrations (3, 6, 9, 13) g by using Hamilton Beach mixer. The rheological properties of prepared samples were measured by using Fan viscometer model 8-speeds. All the samples were subjected to Bingham plastic model. The temperature range studi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 17 2025
Journal Name
Nano Life
Biomedical Assessment of ZnO, MnO and Se Nanoparticles Synthesized via Laser-Induced Plasma: Effects on Thyroid Hormone Levels
...Show More Authors

In this study, nanoparticles were synthesized using the pulsed laser ablation technique, employing an Nd:YAG laser with a wavelength of 1064 nm. The ablation process was carried out at room temperature under varying laser energy of 950 mJ. The structural characteristics of the resulting nanoparticles were investigated using X-ray diffraction (XRD) and atomic force microscopy (AFM). The biological impact of the synthesized nanoparticles was assessed by administering two different doses (1 ml/kg and 4 ml/kg) to experimental animal models. The study evaluated changes in thyroid hormone levels, specifically thyroid-stimulating hormone (TSH), triiodothyronine (T[Formula: see text] and thyroxine (T[Formula: see text]

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The study of thermal description for non-thermal plasma needle system
...Show More Authors

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An in vitro evaluation of shear bond strength of chemical and light-cured bonding materials with stainless steel, ceramic, and sapphire brackets
...Show More Authors

View Publication
Publication Date
Mon Mar 27 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref