Background: Rheumatoid arthritis is a chronic inflammatory autoimmune disease characterized by joint inflammation, involvement of exocrine salivary and lacrimal glands may occur as extra-articular mani¬festations in this disease. This study aimed to provide evidence of altered in function and composition of salivary gland in patients with rheumatoid arthritis by determine salivary flow rate and some biochemical parameters(total protein, amylase, peroxidase) and to investigate the relationship between disease activity and changes in function and composition of salivary gland. Materials and Methods: Fifty five patients with RA (7 males and 48 females) were enrolled in this study with age range (20-69) years. The patients were separated into two groups in proportion to their salivation: normal salivation group (37) and hypo salivation group (18). Thirty five (9 male and 26 female) apparently healthy volunteers were also participated in the study. Three ml of unstimulated saliva was collected from all patients and control to determine salivary flow rate on one hand and salivary total protein, α-amylase and peroxidase by colorimetric method on other hand. Results:Resultsshowed that there is highly significant decrease (P< 0.01; p< 0.001) in the median salivary levels of (flow rate, total protein, α-amylase and peroxidase) among RA patients when compared to control. There was highly significant reduction (P< 0.01) in median salivary levels of flow rate, total protein, α-amylase and peroxidase in two study groups (normal salivation and hypo salivation) as compared to that in control group. Also the levels of all these parameters (sialometry and sialochemistry) were significantly decrease (P =0.00) in RA patients with hypo salivation as compared to that in patients with normal salivation. There was strong positive correlation between total protein and salivary flow rate (r= 0.651, P=0.000), in one hand, and on the other hand, there was strong positive correlation between α-amylase and both salivary flow rate (r=623, P= 0.000) and total protein r=658, P=0.000). Conclusion: These findings indicate that the changes in salivary composition may represent involvement of salivary glands in patients with rheumatoid arthritis.
The present study aims to detect CTX-M-type ESBL from Escherichia coli clinical isolates and to analyze their antibotic susceptibility patterns. One hundred of E. coli isolates were collected from different clinical samples from a tertiary hospital. ESBL positivity was determined by the disk diffusion method. PCR used for amplification of CTX-M-type ESBL produced by E. coli. Out of 100 E. coli isolates, twenty-four isolates (24%) were ESBL-producers. E. coli isolated from pus was the most frequent clinical specimen that produced ESBL (41.66%) followed by urine (34.21%), respiratory (22.23%), and blood (19.05%). After PCR amplification of these 24 isolates, 10 (41.66%) isolates were found to possess CTX-M genes. The CTX-M type ESBL
... Show MoreIn current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show MoreIn this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.
This paper deals with finding an approximate solution to the index-2 time-varying linear differential algebraic control system based on the theory of variational formulation. The solution of index-2 time-varying differential algebraic equations (DAEs) is the critical point of the equivalent variational formulation. In addition, the variational problem is transformed from the indirect into direct method by using a generalized Ritz bases approach. The approximate solution is found by solving an explicit linear algebraic equation, which makes the proposed technique reliable and efficient for many physical problems. From the numerical results, it can be implied that very good efficiency, accuracy, and simplicity of the pre
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show MoreZinc Oxide nanoparticles were prepared using pulsed laser ablation process from a pure zinc metal placed inside a liquid environment. The latter is composed of acetyltrimethylammonium bromide (CTAB) of 10−3 molarity and distilled water. A Ti:Sapphire laser of 800 nm wavelength, 1 kHz pulse repetition rate, 130 fs pulse duration is used at three values of pulse energies of 0.05 mJ, 1.11 mJ and 1.15 mJ. The evaluation of the optical properties for the obtained suspension was applied through ultraviolet–visible absorption spectroscopy test (UV/VIS). The result showed peak wavelengths at 210 nm, 211 nm and 213 nm for the three used pulse energies 0.05 mJ, 1.11 mJ and 1.15 mJ respectively. This indicates a blue shift,
... Show More