Background: Errors of horizontal condylar inclinations and Bennett angles had largely affected the articulation of teeth and the pathways of cusps. The aim of this study was to estimate and compare between the horizontal condylar (protrusive) angles and Bennett angles of full mouth rehabilitation patients using two different articulator systems. Materials and Methods: Protrusive angles and Bennett angles of 50 adult males and females Iraqi TMD-free full mouth rehabilitation patients were estimated by using two different articulator systems. Arbitrary hinge axis location followed by protrusive angles and Bennett angles, estimation was done by a semiadjustable articulator system. A fully adjustable articulator system was utilized to locate the terminal hinge axis using a kinematic face bow followed by protrusive angles location by the aid of two square shaped transparent hard plastic protractors attached close to the condylar stylus of the articulator followed by Bennett angles calculation according to the Hanau formula. All results were subjected to statistical analyses. Results: The two articulator systems scored protrusive angles for male patients greater than female patients which were non-significant for the fully adjustable articulator but they were significant for the semiadjustable articulator. Non-significance existed between females of the fully adjustable articulator and males of the semiadjustable articulator while high significance was located between males of the fully adjustable articulator and females of the semiadjustable articulator. Concerning Bennett angles, the highest mean value belonged to the male group of the fully adjustable articulator, while the lowest scored by the female group of the semiadjustable articulator. Highly significant differences were located between the Bennett angle mean values of the groups. Conclusion: Using both articulators, the total mean values of the males were greater than the females regarding both horizontal condylar angles and Bennett angles with the total means scored by the fully adjustable articulator being larger than those of the semi-adjustable type. Using both articulators, the males' right and left condyles exhibited greater Bennett angles than their female equivalents. The precision estimation of the horizontal condylar angles and Bennett angles provided by the condylar axis protractors of the fully adjustable articulator render such type of articulators most suitable for treating full mouth rehabilitation cases. Keywords: Horizontal codylar angles, Bennett angles, two articulator systems.
This research was one of the terms that used by Al-Bazzar in his musnad and this term was (Al-azza) who launched on some ways and hadiths and I collected those narration, and I have graduated and studied it to access to the meaning which Al-Bazzar want that from this description. In the introduction of the research, I have mention the importance of the subject and the reasons for his selection and also my plan, a preface where I mentioned the definition of Al-Bazzar and his musnad, then in the first section I defined Al-azza linguistically and idiomatically , the second section I studied the hadiths that Al-Bazzar described them with azza ,and then I conclude it with my results that I have reach
... Show MoreThis research raises the issue of the obligation to ensure safety as the most important obligation of tourism and travel companies in the organized trip contract، which is why a tourist chooses this type of trip، If the tourist aims for entertainment and pleasure، he seeks to be sponsored by the organized company to ensure his safe and healthy return home without any damage ، particularly physical damage ، Although this commitment is important، it has not received the attention of the Iraqi legislator، so this research is based on an analytical comparative based on Egyptian and French law as well as English law ، The legislative experience of these States، as well as the views of the op
... Show MoreObjectives To tailor composites of polyethylene–hydroxyapatite to function as a new intracanal post for the restoration of endodontically treated teeth (ETT). Methods Silanated hydroxyapatite (HA) and zirconium dioxide (ZrO2) filled low-density polyethylene (LDPE) composites were fabricated by a melt extrusion process and characterised using infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The flexural strength and modulus were determined in dry state and post ageing in simulated body fluid and fractured surfaces analysed by SEM. The water uptake and radiographic appearance of the experimental composites were also measured and compared with a commercially known endodontic fibre
... Show MoreIn this study, the two researchers try to identify the degree of psychological flow among third-stage students in the College of Physical Education and Sports Sciences / University of Baghdad, by constructing a psychometric flow meter for third-stage students in the College of Physical Education and Sports Sciences / University of Baghdad, and the research sample reached 123 female students They represent 100% of the research community, and after conducting the scientific foundations for building the scale, the two researchers reached the final version of the psychometric flow scale with 21 items with four axes.
The efficiency of Nd:YAG laser radiation in removing debris and smear layer from prepared root
canal walls was studied. Fifty-seven human extracted single rooted anterior teeth were divided into three
groups. A group that was not lased is considered as a control group. The remaining teeth were exposed to
different laser parameters regarding laser energy, repetition rate and exposure time. For the case of the set of
parameters of 7 mJ laser energy, the cleaning was maximum at 3 p.p.s. repetition rate for 3 seconds exposure
time for, the coronal, middle and apical thirds. Above and below this energy level, there was an overdose
(melting) or under dose (no effect). Nevertheless for 10mJ laser energy case, the cleaning effi
The performance of flexible pavements is significantly impacted by the permanent deformation (rutting) of asphalt pavements. Rutting shortens the pavement's useful service life and poses significant risks to those using the highway since it alters vehicle handling characteristics.. The aim of this research is to evaluate the permanent deformation of asphalt mixtures under different conditions,to achieve this aim 108 cylindrical specimens has been prepared and tested under repeated loading in uniaxial compression mode. Five factors were considered in this research, these factors represent the effect of environmental condition and traffic loading as well as mixture properties, they include testing temperature, loading condition (stress level
... Show MoreThis research aims at calculating the optimum cutting condition for various types of machining methods, assisted by computers, (the computer program in this research is designed to solve linear programs; the program is written in v. basic language). The program obtains the results automatically, this occur through entering the preliminary information about the work piece and the operating condition, the program makes the calculation actually by solving a group of experimental relations, depending on the type of machining method (turning, milling, drilling). The program was transferred to package and group of windows to facilitate the use; it will automatically print the initial input and optimal solution, and thus reduce the effort and t
... Show MoreThe nonlinear refractive (NLR) index and third order susceptibility (X3) of carbon quantum dots (CQDs) have been studied using two laser wavelengths (473 and 532 nm). The z-scan technique was used to examine the nonlinearity. Results showed that all concentrations have negative NLR indices in the order of 10−10 cm2/W at two laser wavelengths. Moreover, the nonlinearity of CQDs was improved by increasing the concentration of CQDs. The highest value of third order susceptibility was found to be 3.32*10−8 (esu) for CQDs with a concentration of 70 mA at 473 nm wavelength.
Background: Separation and deboning of artificial teeth from denture bases present a major clinical and labortory problem which affect both the patient and the dentist. The optimal bond strength of artificial teeth with denture base reinforced with nanofillers and flexible denture bases and the effect of thermo cycling should be evaluated. This study was conducted to evaluate and compare the shear bond strength of artificial teeth (acrylic and porcelain) with denture bases reinforced by 5% Zirconium oxide nanofillers and flexible bases under the effect of different surface treatments and thermo cycling and comparing the results with conventional water bath cured denture bases. Material and methods: Two types of artificial teeth; acrylic and
... Show More