Background: Hydrocephalus is an imbalance of cerebro-spinal fluid (CSF) formation & absorption of sufficient magnitude to produce a net accumulation of fluid within to cerebral ventricles.
Aim of study: the main objective of this study is to compare frontal with post parietal shunt regarding the surgery complications , end results & then to compare it with other studies abroad.
Patient & Methods: this study included 920 patients admitted to the Neurosurgical department in the Hospital of surgical specialty,Medical city. The patients had full radiological study including MRI and CT . All patients were surgically managed & followed up for at least one year.
Results: results were & compared regarding the type of surgery we did (VP&VA)shunt. frontal or parieted with other studies.
Conclusion: frontal shunts can be as successful as post parieted shunts, & it carries less complications & lower mortalty although more difficult procedure & needs more experience
The main objective of this study is to characterize the main factors which may affect the behavior of segmental prestressed concrete beams comprised of multi segments. The 3-D finite element program ABAQUS was utilized. The experimental work was conducted on twelve simply supported segmental prestressed concrete beams divided into three groups depending on the precast segments number. They all had an identical total length of 3150mm, but each had different segment numbers (9, 7, and 5 segments), in other words, different segment lengths. To simulate the genuine fire disasters, nine beams were exposed to high-temperature flame for one hour, the selected temperatures were 300°C (572°F), 500°C (932°F) and 700°C (1292°F) as recomm
... Show MoreThe main objective of this paper is to study the behavior of Non-Prismatic Reinforced Concrete (NPRC) beams with and without rectangular openings either when exposed to fire or not. The experimental program involves casting and testing 9 NPRC beams divided into 3 main groups. These groups were categorized according to heating temperature (ambient temperature, 400°C, and 700°C), with each group containing 3 NPRC beams (solid beams and beams with 6 and 8 trapezoidal openings). For beams with similar geometry, increasing the burning temperature results in their deterioration as reflected in their increasing mid-span deflection throughout the fire exposure period and their residual deflection after cooling. Meanwhile, the existing ope
... Show MoreThe main objective of this paper is to study the behavior of Non-Prismatic Reinforced Concrete (NPRC) beams with and without rectangular openings either when exposed to fire or not. The experimental program involves casting and testing 9 NPRC beams divided into 3 main groups. These groups were categorized according to heating temperature (ambient temperature, 400°C, and 700°C), with each group containing 3 NPRC beams (solid beams and beams with 6 and 8 trapezoidal openings). For beams with similar geometry, increasing the burning temperature results in their deterioration as reflected in their increasing mid-span deflection throughout the fire exposure period and their residual deflection after cooling. Meanwhile, the existing ope
... Show MoreThere are a lot of measures for Post Traumatic Stress Disorder (PTSD), but what distinguishes it from other measures is the number of short paragraphs and concise depending on the classification of American Psychiatric Association (APA), which can be applied by the researchers on a large number, Because the Iraqi society suffered from psychological trauma due to wars, conflicts and occupation and the resulting psychological disorders of the members of Iraqi society, especially post-traumatic stress disorder, as mentioned by many studies and researches.
Therefore, the aim of this study was to standardize the PTSD scale for students at Baghdad University. For the Psychologist Fua . E. which was applied in many foreign studies.
A d.c. magnetron sputtering system was designed and fabricated. The chamber of this system is consisted from two copper coaxial cylinders. The inner one used as the cathode and the outer one used as anode with magnetic coil located on the outer cylinder (anode). The axial behavior of the magnetic field strength along the cathode surface for various coil current (from 2A to 14A) are shown. The results of this work are investigated by three cylindrical Langmuir probes that have different diameters that are 2.2mm, 1mm, and 0.45mm. The results of these probes show that, there are two Maxwellian electron groups appear in the central region. As well as, the density of electron and ion decreases with increases of magnetic field strengths.
Background: The normal decline in systolic blood pressure during recovery phase of treadmill exercise dose not occur in most patients with coronary artery disease, in others recovery values systolic blood pressure may even exceed the peak exercise value. Objectives: Treadmill exercise test parameters indicating the presence and extent of coronary artery disease have traditionally included such as exercise duration, blood pressure and ST-segment response to exercise. The three –minute systolic blood pressure ratio is another important indicator of presence and significance of coronary artery disease is useful and obtainable measure that can be applied in all patients who are undergoing stress testing for evaluation of suspected is
... Show MoreBackground: Exposure to Contrast media is the third leading cause of hospital acquired acute kidney injury. It follows a predictable time of onset and a less predictable scenario in recovery. This is related to certain factors, but at the end there will be asubstantial association with increased mortality, morbidity, and length of hospitalization.
Objectives: To define the Incidence of persistent contrast induced renal impairment a month after angiography and to define the risk factors for such persistence
Patients and Methods: One hundred and one patients (101) were enrolled in this study. All were referred to the Iraqi Center for Heart Diseases in Baghdad/ Iraq for coronary and/or peripheral vascular angi
This paper presents experimental results regarding the behaviours of eight simply supported partially prestressed concrete beams with internally unbonded tendons, focusing particularly on the effect of three different variables: concrete compressive strength,
This study deals with the serviceability of reinforced concrete solid and perforated rafters with openings of different shapes and sizes based on an experimental study that includes 12 post-fire non-prismatic reinforced concrete beams (solid and perforated). Three groups were formed based on heating temperature (room temperature, 400 °C, and 700 °C), each group consisting of four rafters (solid, rafters with 6 and 8 trapezoidal openings, and rafter with eight circular openings) under static loading. A developed unified calculation technique for deflection and crack widths under static loading at the service stage has been provided, which comprises non-prismatic beams with or without opening exposed to flexure concentra
... Show MoreIn this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul
... Show More