Coronavirus disease 2019 (COVID-19) is caused by severe acute respiratory syndrome called coronavirus 2 (SARS-CoV-2). Due to its concerning rate of transmission and intensity, coronavirus was classified as a pandemic on March 11, 2020. With the continuous evolution of the viral genome and mutations that may alter infectivity, disease severity or interactions with host immunity, SARS-CoV-2 has evolved into many variants: Alpha (B.1.1.7 lineage), Delta (B.1.617.2 lineage), Delta plus (B.1.617.2.1), Omicron (B.1.1.529 lineage) and other variants. Thus, this study aimed to find and provide database for local clinical characteristics of different variants of SARS-COV-2 and severity of infection with viral load compared with the wild type. A total of 247 nasal swabs were collected from COVID-19 positive patients between March 2021 to March 2022. Specimens were tested by using real time reverse transcriptase polymerase chain reaction rRT-PCR assay to confirm the infection after RNA extraction by specialized kits. Results showed Alpha, Delta, Delta plus and Omicron variants presence in local population at the same time of their global spread at high rates with different cases of severity. The finding showed increase in severity with Alpha 79/87 (90%), wild type 26/32 (81%) (with 3 mortality cases), Delta/ Delta plus 68/84 (80%) and Kappa only one case. Also, Alpha along with the wild type was more associated to severe and critical cases, while mild to moderate group appeared with Omicron variant (32/43 (74%)). In addition, there was an increase in the severity among older patients (>40) and in men more than the women. Results indicate that although the wild type was no less dangerous or severe than Alpha or other variants, but with continuous appearence of new variants led to its reduced prevalence. In conclusion, findings demonstrated that most of the severe and critical cases had infection with Alpha, wild type than Delta or Delta plus variants. Whereas mild to moderate cases occurred in Omicron variants.
This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show More In this paper, we introduce a new type of functions in bitopological spaces, namely, (1,2)*-proper functions. Also, we study the basic properties and characterizations of these functions . One of the most important of equivalent definitions to the (1,2)*-proper functions is given by using (1,2)*-cluster points of filters . Moreover we define and study (1,2)*-perfect functions and (1,2)*-compact functions in bitopological spaces and we study the relation between (1,2)*-proper functions and each of (1,2)*-closed functions , (1,2)*-perfect functions and (1,2)*-compact functions and we give an example when the converse may not be true .
چکیدهی بحث
به نظر میآید که عالم هستی ، بر مسألهی « حرکت» استوار دارد ، و روح ، همیشه دنبال دگرگونی و تکامل و برتری میگردد. حرکت ، همهی چیزها در عالم إمکان را در بر میگیرد. حرکت در بنیادهای فکر مولانا جای مهمی دارد .اشعار مولانا مقدار زیادی از پویایی و حرکت برخوردارست، و از آنجایی که فعل ، عنصر تکانبخش جمله ، و کانون دلالت است ، ترجیح دادیم - علاوه بر دیگر عنا
... Show MoreTwo well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95
... Show MoreThe effect of thickness variation on some physical properties of hematite α-Fe2O3 thin films was investigated. An Fe2O3 bulk in the form of pellet was prepared by cold pressing of Fe2O3 powder with subsequent sintering at 800 . Thin films with various thicknesses were obtained on glass substrates by pulsed laser deposition technique. The films properties were characterized by XRD, and FT-IR. The deposited iron oxide thin films showed a single hematite phase with polycrystalline rhombohedral crystal structure .The thickness of films were estimated by using spectrometer to be (185-232) nm. Using Debye Scherrerś formula, the average grain size for the samples was found to be (18-32) nm. Atomic force microscopy indicated that the films had
... Show More