In recent years, the iris biometric occupies a wide interesting when talking about
biometric based systems, because it is one of the most accurate biometrics to prove
users identities, thus it is providing high security for concerned systems. This
research article is showing up an efficient method to detect the outer boundary of
the iris, using a new form of leading edge detection technique. This technique is
very useful to isolate two regions that have convergent intensity levels in gray scale
images, which represents the main issue of iris isolation, because it is difficult to
find the border that can separate between the lighter gray background (sclera) and
light gray foreground (iris texture). The proposed method tried to find iris radius by
seeking in the two iris halves (right and left) circularly, in term of certain angles
interval for each half, to avoid the existence of the upper and lower eyelids and
eyelashes. After the two radiuses (i.e. for each half) had been determined, the iris
final iris radius would be evaluated to the minimum value of them. This method
tested on all samples of CASIAv4-Interval dataset, which consist of 2639 samples,
captured from 249 individuals, and distributed on 395 classes, the accuracy of the
testing was 100% for outer boundary detection.
The present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.
Doppler broadening of the 511 keV positron annihilation ??? ? was used to estimate the concentration of defects ?? different deformation levels of pure alnminum samples. These samples were compressed at room temperature to 15, 22, 28, 38,40, and 75 % thickness reduction. The two-state ^sitron-trapping model has been employed. 'I he s and w lineshape parameters were measured using high-resolution gamma spectrometer with high pure germanium detector of 2.1 keV resolution at 1.33 MeV of 60Co. The change of defects concentration (Co) with the deformation level (e) is found to obey an empirical formula of the form Cd - A £ B where A and ? are positive constants that depend mainly on the deformation procedure and the temperature at which the def
... Show MoreSimulation of direct current (DC) discharge plasma using
COMSOL Multiphysics software were used to study the uniformity
of deposition on anode from DC discharge sputtering using ring and
disc cathodes, then applied it experimentally to make comparison
between film thickness distribution with simulation results. Both
simulation and experimental results shows that the deposition using
copper ring cathode is more uniformity than disc cathode
Semiparametric methods combined parametric methods and nonparametric methods ,it is important in most of studies which take in it's nature more progress in the procedure of accurate statistical analysis which aim getting estimators efficient, the partial linear regression model is considered the most popular type of semiparametric models, which consisted of parametric component and nonparametric component in order to estimate the parametric component that have certain properties depend on the assumptions concerning the parametric component, where the absence of assumptions, parametric component will have several problems for example multicollinearity means (explanatory variables are interrelated to each other) , To treat this problem we use
... Show MoreIn this work, the effect of laser energy on the properties of a calcium plasma generated by a Q-switched Nd: YAG laser at the fundamental wavelength was studied using spectroscopy. The Boltzmann plot and Stark broadening method were used to measure the main plasma parameters (electron temperature and electron density). The electron temperature ranged ( 0.169 -0.172 ) eV, the electron density ranged ( 2.10 – 2.63 ) for laser energy range of ( 400 – 700) mJ. Other basic plasma properties were also measured, including the Debye length, the number of particles in the Debye sphere, and the plasma frequency. Laser energy affects all plasma parameters, according to our results.
Pure SnSe thin film and doped with S at different percentage (0,3,5,7)% were deposited from alloy by thermal evaporation technique on glass substrate at room temperature with 400±20nm thickness .The influences of S dopant ratio on characterization of SnSe thin film Nano crystalline was investigated by using Atomic force microscopy(AFM), X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), Hall Effect measurement, UV-Vis absorption spectroscopy to study morphological, structural, electrical and optical properties respectively .The XRD showed that all the films have polycrystalline in nature with orthorhombic structure, with preferred orientation along (111)plane .These films was manufactured of very fine crystalline size in the ra
... Show MoreStoring and transferring the images data are raised in recent years due to requisiteness of transmission bandwidth for considerable storage capacity. Data compression method is proposed and applied in an attempt to convert data files into smaller files. The proposed and applied method is based on the Wavelet Difference Reduction (WDR) as considered the most efficient image coding method in recent years. Compression are done for three different Wavelet based Image techniques using WDR process. These techniques are implemented with different types of wavelet codecs. These are Daub2+2,2 Integer Wavelet transform, Daub5/3 integer to integer wavelet transform, and Daub9/7 Wavelet transform with level four. The used mu
... Show MoreThe aim of this paper is to present a semi - analytic technique for solving singular initial value problems of ordinary differential equations with a singularity of different kinds to construct polynomial solution using two point osculatory interpolation. The efficiency and accuracy of suggested method is assessed by comparisons with exact and other approximate solutions for a wide classes of non–homogeneous, non–linear singular initial value problems. A new, efficient estimate of the global error is used for adaptive mesh selection. Also, analyze some of the numerical aspects
... Show More