The present work aims to evaluate the content of some toxic metals in chemical and organic fertilizers purchased from local markets in Baghdad, Iraq. The analysis was performed by laser-induced breakdown spectroscopy (LIBS) system. The emission spectral lines of lead (Pb), chromium (Cr), cadmium (Cd) and cobalt (Co) have been recorded to determine the best peak representing each element according to the NIST database. The validity of the LIBS procedure was checked by cross-validating the obtained results using atomic absorption spectroscopy (AAS) with a maximum relative error of 5.3%. Moreover, for qualitative analysis, Pb I 296.64 nm emission line was determined to be superior for the evaluation of lead content in terms of three calibration methods: the external standard (ES), the internal standard (IS), and the multiple linear regression (MLR). The linear correlation coefficient values were : 0.94, 0.97 and 0.992, respectively. LIBS results based on the multiple linear regression (MLR) model have demonstrated better performance and were adopted in the assessment of the Pb content in solid fertilizer samples.
The objective of this study is to determine the concentration of copper and lead (mg/L) in drinking water by using absorption spectrophotometic and Atomic Absorption spectrophotometric method from different area in Baghdad and with different intervals , The results show that the concentration of copper and Lead ( mgL) in tap water which remains motionless in plumbing system for following periods one hours, 3 hours, 6 hours, 12 hours, 24 hours, 7 days and 14 days are (1 , 2.2 , 4 , 5.3 , 7.5 , 10 and 16 mgL copper ) & ( 0.3, 0.5 , 0.8 , 1 , 2.5 , 3 , 3.8 mg /L lead ) respectively .from these results its clear that high levels of copper & Lead occur if tap water comes in contact with copper - lead plumbing and copper lead -containing fix
... Show MorePlasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri
... Show MoreFluorescence excitation by Nd:YAG pumped dye laser and single vibrational level fluorescence
spectra of 1,3 benzodioxole in a supersonic jet have been obtained and interpreted. The previous assignment of
the 0 0
0 band was incorrect. In addition, many other bands involving n20 and n19 vibrations of a2 symmetry were
confirmed. As far as a1 totally symmetric vibration is concerned. The n14 was assigned to be located in the fivemembered
ring whereas n13 seem to be located in the benzene ring as a result of the electronic transition in the
benzene ring which affects n13 and not n14 wavenumber.
The present work investigated the effect of distance from target surface on the parameters of lead plasma excited by 1064nm Q-switched Nd:YAG laser. The excitation was conducted in air, at atmospheric pressure, with pulse length of 5 ns, and at different pulse laser energies. Electron temperature was calculated by Boltzmann plot method based on the PbI emission spectral lines (369.03 nm, 416.98 nm, 523.48, and 561.94 nm). The PbI lines were recorded at different distances from the target surface at laser pulse energies of 260 and 280 mJ. The emission intensity of plasma increased with increasing the lens-to-target distance. The results also detected an increase in electron temperature with increasing the di
... Show MoreA simple, accurate and sensitive spectrophotometric method for the determinaion of epinephrine is described . The method is based on the coordination of Pr (III) with epinephrine at pH 6. Absorbance of the resulting orange yellow complex is measured at 482 nm . A graph of absorbance versus concentrations shows that beer 's low is obeyed over the concentration range (1-50)mg.ml-1 of epinephrine with molar absorpitivity of ( 2.180x103 L.mol-1.cm-1 ), a sandell sensitivity of (0.084 mg.cm-2 ), a relative error of (-2.83%) , a corrolation coffecient (r= 0.9989) and recovery % ( 97.03 ± 0.75 ) depending on the concentration.This method is applied to analyse EP in several commercially available pharmaceutical preparations
... Show Morepresent in the environment could constitute a hazard to food security and public health. These can be accumulated in aquatic animals such as fish.
Objective: In this study, selected heavy metals: Copper (Cu), Nickle (Ni), Chromium (Cr) and Iron (Fe) were evaluated in commercial canned fish products (Sardines) that are commonly consumed in Iraq. The canned fish (Sardine) which studied were Yacout Sardine (Morocco), Marina Sardine (Tunisia), Silver Sardine (Morocco) and Salsa Sardine (China).
Methods: Prospective study was done in Baghdad from January to June 2016 . 40 samples of four different foreign brands (10 samples for each brand were obtained): Yacout Sardine (Morocco), Marina Sardine(Tunisa), Silver Sardine (Morocco) and Sals
The current study was achieved on the effects of laser energy and annealing temperature on x-ray structural and optical properties, such as the UV-Visible spectra of cadmium sulfide (CdS). The films were prepared using pules laser deposition technique (PLD) under vacuum at a pressure of 2.5×10-2 mbar with different laser energies (500-800 mJ) and annealing at a temperature of 473K. X-ray diffraction patterns and intensity curves for the CdS showed that the formation of CdS multi-crystallization films at all laser energies. The optical properties of the films were studied and the variables affecting them were investigated in relation to laser energy and changes in temperature.
The concentrations of Pb, Zn, Hg and Cu were determined in twenty sample of canned fish, samples were collected with different origin with two meals from local markets at Baghdad city for the period (October 2012-February 2013),results of study were appeared variation in mercury concentration of canned fish between November and February .The highest concentration of mercury (0.1 mg/kg) was observed in “Hawesta” brand and “Ocean wave” ” brand , the lowest average concentration for mercury 0.01ppm in “Habar”,”Durra” and ”Sayad” brand during( Nov.2012-Feb.2013 ) and have not recorded any concentration for mercury in “Yasmine” brand during (Nov. 2012-Feb. 2013).The maximum level of zinc reached in November. rather t
... Show MoreIn this work; Silicon dioxide (SiO2) plasma plume was prepared by laser induced plasma (LIP). The electron number density, plasma frequency and Debye length were calculated by reading the data of I-V curve of Langmuir probe which was used as a diagnostic method of measuring plasma properties. Pulsed Nd:YAG laser was used for measuring the electron number density of SiO2 plasma plume under vacuum environment with varying both vacuum pressure and axial distance from the target surface. Some physical properties of the plasma generated such as electron density, plasma frequency and Debye length have been measured experimentally and the effects of vacuum pressure and Langmuir probe distance from the target were studied on those variables. An
... Show MoreLaser cleaning of materials’ surfaces implies the removal of deposited pollutants without affecting the material. Nanosecond Nd:YAG pulsed laser, operating at 1064 nm and 532nm, was utilized. Different laser intensities and number of pulses were used on metallic and non-metallic surfaces under O2 and Ar environments to remove metal oxide and crust. Cleaning efficiency was studied by optical microscope. The results indicated the superiority of 1064 nm over the 532 nm wavelength without any detectable damage to materials’ surfaces. Marble cleaned in Oxygen gas environment was better than in Ar gas.