The objective of this study is to determine the concentration of copper and lead (mg/L) in drinking water by using absorption spectrophotometic and Atomic Absorption spectrophotometric method from different area in Baghdad and with different intervals , The results show that the concentration of copper and Lead ( mgL) in tap water which remains motionless in plumbing system for following periods one hours, 3 hours, 6 hours, 12 hours, 24 hours, 7 days and 14 days are (1 , 2.2 , 4 , 5.3 , 7.5 , 10 and 16 mgL copper ) & ( 0.3, 0.5 , 0.8 , 1 , 2.5 , 3 , 3.8 mg /L lead ) respectively .from these results its clear that high levels of copper & Lead occur if tap water comes in contact with copper - lead plumbing and copper lead -containing fixtures in the water distribution system. If tap water remains motionless in the plumbing system for some time. These amounts of copper and Lead are believed to give rise to the symptoms of chemical food poisoning precipitated by the ingestion of alcohol on an empty stomach ( in presence of copper ). Also children under one year of age are more sensitive to copper than adults. Long-term exposure (more than 14 days) to copper - lead in drinking water which is much higher than 1,000 ug/I has been found to cause kidney and liver damage in infants, In case of Lead it can effect a children physical development & ability to learn.
Atotal of 551 water samples drinking( five Water Treatment Plans (WTPs) and raw water( from different sites on Tigris river) were collected.According to morphological characteristics and a set of biochemical tests, one hundred twenty eight of Aeromonas spp isolates were obtained In this study The percentages of Aeromonas recovery from river water was 72.52%, from wells water was (35%).Total percentage of positive aeromonas samples of treated water(Filtration &chlorine tank, supply water of WTPs, distribution system, reserviores and other samples not related to WPTs) was 8.8%.Count of Aeromonas in positive aeromonas samples ranging from 1 to 175 cfu 100 ml.
The results showed that generally no significant correlation between presen
study was conducted on a stretch of Tigris river crossing Baghdad city to determine the concentration of some chlorophenols pollutants. Aqueous samples were preliminary enriched about 500 times and the chlorophenols have determined using high performance liquid chromatography HPLC. Limits of detection LOD were (0.007–0.012 mg L-1), relative standard deviations RSD% were 2.4%–5.59% and relative recoveries were 51.06%– 104.07%. The existence of chlorophenols in Tigris river was in the range 0.023–4.596 mg L-1. The developed method suggested in this study can be applied for routine analysis and monitoring of chlorinated phenols in environmental aqueous samples.
One of the bigger problems in drinking water is disinfection by-products (DBPs) that come from chlorinated disinfection. This study’s goal was to evaluate the drinking water in Al-Yarmouk Teaching Hospital, Ibn Sina Hospital and Ibn-Al-Nafis Hospital. Samples were collected between October 2018 and September 2019. Physical and chemical characteristics of the water were studied, including (temperature, hydrogen ion (pH), total dissolved solids (TDS), electrical conductivity (EC), turbidity, free residual chlorine, total organic carbon (TOC), total trihalomethanes (THMs), total halo acetic acid (THAAs)). Data analysis showed the highest value of study temperatu
... Show MoreThis study was conducted to determine the ability of water treatment system (Vortisand) to reduce some chemical and physical properties for tigris river raw water, It consisted of turbidity, electrical conductivity, pH, total hardness, calcium Hardness as well as temperature in order to determine the unit`s efficiency for reducing their concentration as compared to those in the water produced by some classical potable water projects (Dora and Wathba) in Baghdad. Samples were collected during the cold months (December 2016 and January 2017) and during the hot months (May and June 2017). The results showed that this system has the ability to reduce some properties such as turbidity, the values were 215NTU in raw water and decreased to NTU
... Show MoreIn the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon
Background: The quality of drinking water is directly related to community health. Therefore, improving the quality of drinking reflects positively on the health situation in general. The studies that deal with the quality of drinking water in the city of Baghdad in terms of chemical or microbial content are very scanty. Objective: The current review highlights the most important studies and research articles that concern the quality of drinking water, both bottled water and tap water, in terms of chemical and biological contamination and chemophysical specifications for drinking water. Abstract: Studies have shown that drinking water in the city of Baghdad, especially tap water, contains certain levels of heavy metals,
... Show MoreDue to the significance of hospital drinking water, a study was done to assess the water in three hospitals in Baghdad (Al-Yarmouk Teaching Hospital, Ibn Sina Hospital, and Ibn-Al-Nafis Hospital) for its nature and quality, compare it to other hospitals in terms of its physical, chemical, and bacterial specifications, and compare it to international standards. According to Iraqi standards from 2009 and WHO standards from 2011, Chemical factors were measured, which included pH, Total Dissolved Solids (TDS), and Calcium Ion (Ca+2). Reported readings are all within acceptable ranges for drinking water. In contrast, turbidity, total hardness (T.H.), chlorides (Cl-), magnesium (Mg+2), the number of aerobic plates (APC), total coliform (T
... Show MoreThe current study was conducted on 100 females who were divided into two main groups; 60 with breast cancer and 40 healthy controls. Blood samples were collected from both premenopausal and postmenopausal breast cancer and healthy women. The samples were appropriately processed for the analysis of trace elements (zinc, copper, and lead) by using flame atomic absorption spectrophotometry (FAAS). The results showed a highly significant decrease (p< 0.01) in the mean serum level of zinc of in both pre- and postmenopausal breast cancer women (71.7 + 5.1 and 70.4 + 5.4 µg/dL, respectively) compared with healthy controls (89.7 + 10.2 and 97.5 + 13.2 µg/dL, respectively) . Also, a highly significant
... Show MoreThe ability of A.hydrophila isolates (63 isolates) to form biofilm, was studied and the results showed that fifty six isolates (88.8%) gave positive results in Congo red agar, while 51 isolates ( 80.7%) gave positive results in Christensen method, sixty isolates( 95.2%) produced biofilm on Polystyrene microtiter plates. Results revealed that all drinking water isolates produced biofilm (18 isolates )and 42 raw water isolates produced biofilm (depending on Polystyrene microtiter plates test). The more two efficient isolates(one isolated from drinking water DW, and other isolated from raw watervRW) which produced biofilm was chosen to study the effect of different values of temperature and disinfectants on the ability of A.hydrophila to ad
... Show MoreThe wide use of lead compounds as an engine anti-knock reflects conversely on all components of the ecosystem. This study aimed to detect the concentration of lead in various types of gasoline and gas oil that are highly consumed by vehicles. Eight fuel samples were collected from different feul stations distributed in different districts of Baghdad city. These included two gas oil (diesel) stations and three stations for each type of gasoline (leaded and unleaded). Lead was extracted by the modified chemical method, and then flame atomic absorption technique was applied to assay its concentrations. The results indicated that lead levels were within permitted limits (150 mg Lead L-1) recommended by the
... Show More