Preferred Language
Articles
/
ijs-3478
Preliminary Assessment of the Soil Foundation Characteristics Utilizing the 2D Resistivity Imaging and Down-Hole Seismic Refraction Techniques: A Case Study in Tenth of Ramadan City, Egypt
...Show More Authors

      Two-dimensional electrical resistivity imaging and seismic refraction, in the form of down-hole survey, were applied to delineate the subsurface section and elastic moduli and identify geotechnical characteristics of subsurface materials in the 10th of Ramadan industrial area, Cairo, Egypt. The results of four 2-D profiles of electrical resistivity, in the form of dipole–dipole and Wenner configurations, revealed that the subsurface section contains two main geo-electrical layers; the first is made of sand, some silt, and gravels, reflecting low resistivity values ranging from 25 to 65.5 ohm m. This layer is overlying a high resistivity layer (65.5 to135 ohm m), corresponding to medium to coarse sand, with gravel and calcareous materials. It is worth noting that that the down-hole technique was used to measure velocities of P and S waves in order to derive the low strain dynamic elastic properties, such as Poisson’s ratio, Shear modulus, stress ratio, concentration index, N-value, and the ultimate and allowable bearing capacities of the subsurface soil, down to an approximate depth of 30 m in the borehole at the site. In addition, the Vs30 value was calculated and revealed that the soil is categorized as a NEHRP class (D). Furthermore, the results of geotechnical parameters and elastic moduli were found to be realistic and sensible for the purposes of engineering constructions and imply that the soil in the study area is characterized by fairly to moderately competent quality. A new empirical correlation is proposed between the obtained Vs and resistivity values, where Vs = 1.0302 ρ + 172.74.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Engineering
Assessment of Bearing Capacity and Settlement Characteristics of Organic Soil Reinforced by Dune Sand and Sodium Silicate Columns: A Numerical Study
...Show More Authors

Organic soil is problematic soils in geotechnical engineering due to its properties, as it is characterized by high compressibility and low bearing capacity. Therefore, several geotechnical techniques tried to stabilize and improve this soil type. In this study, sodium silicate was used to stabilize sand dune columns. The best sodium silicate concentration (9%) was used, and the stabilized sand dune columns were cured for seven days. The results for this soil were extracted using a numerical analysis program (Plaxis 3D, 2020).In the case of studying the effect of (L/D) (where ‘’L” and ‘’D’’ length and diameter of sand dune columns) of a single column of sand dunes stabilized with sodium silicate with a diff

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 30 2021
Journal Name
Iraqi Journal Of Science
Stratigraphic Study for the Cretaceous-Tertiary period in Qasab-Jawan area in north weastern Iraq by using 2D seismic survey
...Show More Authors

     A seismic study was conducted to re-interpret the Qasab and Jawan Oil fields in northwestern Iraq, south of the city of Mosul, by reprocessing many seismic sections of a number of field surveys by using the Petrel software. Two reflectors, represented by the Hartha formation, deposited during the Cretan age, and the Euphrates formation, formed during the Tertiary age, were delineated to stabilize the structural picture of these fields.

The stratigraphic study showed that the Qasab and Jawan fields represent areas of hydrocarbon accumulation. Seismic attribute analysis showed low values of instantaneous frequency in the areas of hydrocarbon accumulation. Instantaneous phase was used to determine the limits

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Aug 31 2021
Journal Name
Iraqi Journal Of Science
An Investigation of Seismic Velocity Variation through a Tectonic Boundaries-Case Study in Central Iraq
...Show More Authors

      A 3D velocity model was created by using stacking velocity of 9 seismic lines and average velocity of 6 wells drilled in Iraq. The model was achieved by creating a time model to 25 surfaces with an interval time between each two successive surfaces of about 100 msec.  The summation time of all surfaces reached about 2400 msec, that was adopted according to West Kifl-1 well, which penetrated to a depth of 6000 m, representing the deepest well in the study area. The seismic lines and well data were converted to build a 3D cube time model and the velocity was spread on the model. The seismic inversion modeling of the elastic properties of the horizon and well data was applied to achieve a corrected veloci

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Iraqi Journal Of Science
2D Seismic Data Analysis of Judaida Structure, Northern Iraq
...Show More Authors

This research aims to study the structural analysis of the 2D reflection seismic data for the Judaida subsurface structure located in Kirkuk province, northern Iraq. It is located 60 Km southwest of Kirkuk oil field, and 35 Km southwest of Jambur oil field, the Daquq River passes through the study area. The reflectors in the seismic section were picked and identified by using the synthetic seismograms generated from the logs data of the Jd-1 well. Three main seismic reflectors, Fatha, Jeribe, and the Euphrates were chosen. These mentioned sedimentary formations were deposited during the Middle Miocene, Lower Miocene, and Early-Mid Miocene respectively. Time and depth maps were drawn for these three reflectors by processing average data f

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Iraqi Journal Of Science
The Relation Between the Variation of Electrical Resistivity Values and Moisture of Soil at Baghdad University, Iraq
...Show More Authors

     Six ERI profiles using Wenner Schlumberger array were carried out at Baghdad University (ALJadiriya campus) to investigate soil at two sites. The spacing between electrodes of four profiles surrounding the new building in the Campus at the first site is 1 m, and the profile length ranges from 50 to 90 m. In comparison, two across profiles in the garden to detect water seepage in the site. The inverted model of the studied profiles shows many high and low resistivity zone. The sedimentology and mineralogy of the soil samples analysis from a depth range of 15 to 100 cm from three pits confirm the high homogeneity of the soil in the studied site composed of (silt and clay). The low resistivity values coincided with the moisture a

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Feb 13 2023
Journal Name
International Conference Of Computational Methods In Sciences And Engineering Iccmse 2021
Management of the flood disaster and assessment their damaged areas using remote sensing and GIS techniques: A case study of Tigris River – Maysan Governorate, Iraq
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Heave Behavior of Granular Pile Anchor-Foundation System (GPA-Foundation System) in Expansive Soil
...Show More Authors

Granular  Pile  Anchor  (GPA)  is  one  of  the  innovative  foundation  techniques,  devised  for mitigating heave of footing resulting from the expansive soils. This research attempts to study the heave behavior of (GPA-Foundation System) in expansive soil. Laboratory tests have been conducted on an experimental model in addition to a series of numerical modeling and analysis using the finite element package PLAXIS software. The effects of different parameters, such as (GPA) length (L) and diameter (D), footing diameter (B), expansive clay layer thickness (H) and presence of non-expansive clay are studied. The results proved the efficiency of (GPA) in reducing the heave of exp

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Agronomy
A Case Study of Potential Reasons of Increased Soil Phosphorus Levels in the Northeast United States
...Show More Authors

Recent phosphorus (P) pollution in the United States, mainly in Maine, has raised some severe concerns over the use of P fertilizer application rates in agriculture. Phosphorus is the second most limiting nutrient after nitrogen and has damaging impacts on crop yield if found to be deficient. Therefore, farmers tend to apply more P than is required to satisfy any P loss after its application at planting. Several important questions were raised in this study to improve P efficiency and reduce its pollution. The objective of this study was to find potential reasons for P pollution in water bodies despite a decrease in potato acreage. Historically, the potato was found to be responsible for P water contamination due to its high P sensitivity a

... Show More
View Publication
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Effect of Saturation of Sandy Soil on the Displacement Amplitude of Soil Foundation System under Vibration
...Show More Authors

In this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. A physical model was manufactured to simulate steady state harmonic load at different operating frequencies. The effect of relative density, depth of embedment, foundation area as well as the imposed harmonic load was investigated. It was found that the amplitude of displacement of the foundation increases with increasing the amplitude of dynamic force and operating frequency meanwhile it decreases with increasing the relative density of sand, degree of saturation, depth of embedment and contact area of footing. The maximum displacement was noticed at 33.34 to 41.67 Hz. The maximum displaceme

... Show More
View Publication Preview PDF