Preferred Language
Articles
/
ijs-7809
The Relation Between the Variation of Electrical Resistivity Values and Moisture of Soil at Baghdad University, Iraq
...Show More Authors

     Six ERI profiles using Wenner Schlumberger array were carried out at Baghdad University (ALJadiriya campus) to investigate soil at two sites. The spacing between electrodes of four profiles surrounding the new building in the Campus at the first site is 1 m, and the profile length ranges from 50 to 90 m. In comparison, two across profiles in the garden to detect water seepage in the site. The inverted model of the studied profiles shows many high and low resistivity zone. The sedimentology and mineralogy of the soil samples analysis from a depth range of 15 to 100 cm from three pits confirm the high homogeneity of the soil in the studied site composed of (silt and clay). The low resistivity values coincided with the moisture and amount of vegetable and herbs growth. Therefore, the authors believe the main factor causing variation in the resistivity value in the study area is the moisture Factor.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 11 2021
Journal Name
Sustainable Civil Infrastructures
Field Soil Electrical Resistivity Measurements of Some Soil of Iraq
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Detection of A Possible Subsurface Water Seepage Using 2D Electrical Resistivity Imaging Survey at a site in Al-Khwarizmi College of Engineering, University of Baghdad, Iraq
...Show More Authors

     Unknown subsurface leaking water sources and possible subsurface seepage from a sewage tank in a garden at Al-Khawarizmi engineering college, University of Baghdad, were detected in this study. The 2D electrical resistivity imaging. The ERI survey is carried out along two lines, 60m and 50m long, with an electrode spacing of 1 m, forming a cross using the Wenner-Schlumberger array configuration. Line 1 is 60m, while line 2 is 50m. Soil samples were collected from line 1 at positions of electrode 34, which shows a high resistivity value, and electrode 55, which shows low resistivity, for laboratory analysis. Robust inversion and modelling processes showed relative change and high contrast in interpreted resistivities. Soil analy

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Science
Electrical Resistivity Imaging (ERI) for Identifying Near-surface Bodies at Diyala University site, NE of Iraq
...Show More Authors

      The current research demonstrates the ERI method's effectiveness as a supplementary engineering site investigation approach. Engineering site research is important to indicate the subsoil of proposed production sites. The benefit of the dipole-dipole array for ERI electrical resistivity imaging is that it provides informative records of subsurface geology and condition along with profiles. The dipole-dipole array was performed along with three parallel profiles at the Diyala University site to identify the buried facilities (pipes and cables) in the area. The buried electric cable embedded in a plastic tube was used for simulation to report and verify the field resistivity results. Interpretation of field facts confirmed that

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Jun 27 2020
Journal Name
Iraqi Journal Of Science
Application of the Electrical Resistivity Method for Site Investigation in University of Anbar, Ar-Ramadi City, Western Iraq
...Show More Authors

The 2D resistivity imaging technique was applied in an engineering study for the investigation of subsurface weakness zones within University of Anbar, western Iraq. The survey was carried out using Dipole-dipole array with an n-factor of 6 and a-spacing values of 2 m and 5 m. The inverse models of the 2D electrical imaging clearly show the resistivity contrast between the anomalous parts of the weakness zones and the background resistivity distribution. The thickness and shape of the subsurface weakness zones were well defined from the 2D imaging using Dipole-dipole array of 2 m a-spacing. The thickness of the weakness zone ranges between 9.5 m to 11.5 m. Whereas the Dipole-dipole array with a-spacing of 5 m and n-factor of 6 allocated

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (2)
Scopus Crossref
Publication Date
Wed Nov 30 2022
Journal Name
Iraqi Journal Of Science
Comparison of Three Electrical Resistivity Arrays to Investigate Weak Zones in Soil, Along a Profile Southeast Baghdad City, Iraq
...Show More Authors

     The electrical resistivity method is one of the geophysical methods for detecting weak subsurface zone. The 2D resistivity data were used to compare three electrode configurations, Wenner, Dipole-dipole, and Schlumberger, to detect weak subsurface zones along a profile south of Baghdad near the Bismayah pumping station. The results show many zones of low resistivity that may be weak zones. A dipole-dipole array is a large number of measurements and is more sensitive than others. The Wenner-Schlumberger array has a depth also higher than other arrays. Wenner array has higher signal strength than other arrays. Because it is more sensitive to horizontal and vertical structures, the dipole-dipole array is the optimum for mapping sub

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Nov 30 2021
Journal Name
Iraqi Journal Of Science
The Effects of Some Physical and Chemical Factors on Apparent Resistivity of Surface Soil in the University of Mosul, Mosul City, Northern Iraq
...Show More Authors

Soil resistivity depends on many overlapping factors, which influence it in various ways. The aim of this study was to determine the effects of some physical and chemical factors on soil apparent resistivity. The results of field, laboratory, and statistical studies revealed a complex relationship between water content, pH, and salinity with soil apparent resistivity. The results showed that water content had a clear effect on apparent resistivity, as it increased significantly when water content value decreased to less than about 5%. The results also showed that increasing the salinity ratio at the expense of water content led to an increase in the apparent resistivity values. The apparent resistivity values also increased significantly

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Application of 2D Electrical Resistivity Imaging Technique for Detecting Soil Cracks: Laboratory Study
...Show More Authors

Cracking of soils affects their geotechnical properties and behavior such as soil strength and stability. In this paper, 2D Electrical Resistivity Imaging Method, as a non-invasive technique, was adopted to investigate the effect of soil cracks of a centemetric scale on resistivity of sandy soil. The electrical resistivity measurements were carried out using ABEM SAS 300C Terrameter system at a laboratory scale using Wenner array. The measurements were interpreted using horizontal profiles, forward modeling and 2D inverse resistivity sections. The results showed that soil cracks cause significant changes in soil resistivity. These changes can be attributed to the high resistivity contrast between the highly resistive air-filled cracks an

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 30 2023
Journal Name
Iraqi Journal Of Science
3D Resistivity Imaging Investigation for Engineering Construction Project Studies at Al-Muthana Airport in Baghdad, Iraq
...Show More Authors

     Engineering project assessment at Al-Muthana Airport in Baghdad, Iraq, has been studied using a 3D electrical resistivity imaging survey. The site investigation is crucial for assessing the future of the region's infrastructures since it reveals the location of buried facilities or weak zones below the surface and measures localized groundwater levels. Wenner-Schlumberger array was used to conduct four parallel 2D electrical resistivity spreads (MU1 to MU4). Each spread line was 100 m in length with 1 m electrode spacing and an average spacing of 9 meters between any two adjacent lines. The depth of the investigation was around 23.8 m. Survey lines were drawn going from northwest to southeast. These spreads were combined to prov

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jan 15 2021
Journal Name
Int. J. Agricult. Stat. Sci.
THE IMPACT OF PLOWING DEPTH AND SOIL MOISTURE ON SOME TECHNICAL INDICATORS AT USING DISK PLOW
...Show More Authors

An experiment was carried out in a field in Husayniyah sub-district of the Holy Karbala Governorate. The research included studying the impact of the plowing depth and soil moisture on some technical indicators when using the disc plow. The 80 hp New Holland tractor was used in this experiment. Two factors were studied, the first factor is the soil moisture (12- 9%), (16-13%) and (20-17%) and the second factor was the depth of tillage (10-13) cm, (15-18) cm and (20-23) cm, which represented the secondary blocks. Bulk density, percentage of slippage and drawing force were studied. The field trials was conducted according to Split blocks in a randomized complete block design in three replicate. Consequences showed (according to the conditions

... Show More
Publication Date
Mon May 15 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of the Heavy Metals in the Contaminated Soil Zones at College of Education Ibn Al-Haitham -University of Baghdad
...Show More Authors

  Soil is a crucial component of environment. Total soil analysis may give information about possible enrichment of the soil with heavy metals. Heavy metals, potentially contaminate soils, may have been dumped on the ground. The concentrations of soil heavy metals (Cd, As, Pb, Cr, Ni, Zn and Cu) were measured in three zones thought to be deeply contaminated at different depths (5, 25, 50 cm) at Ibn Al-Haitham College. The highest concentration of heavy metals Pb (63.3ppm), Cr (90.7ppm), Ni (124ppm) and Cu (75.7ppm) were found in zone (A) location-1, where the highest concentration of Zn (111.7ppm) was found in zone (C). Cd and As were detected in small amounts in all zones.     PH value, organic matters, carbonat

... Show More