A total of 157 clinical samples were collected from different clinical specimens (urine, sputum, blood, swabs, and cannula) from several hospitals in Iraq. Among the samples, 51 isolates (32.48%) of Klebsiella pneumoniae were identified according to morphologicaland cultural characteristics as well as the Enterosystem 18R test. Higher numbers of K. pneumoniae isolates were observed in urine samples (26, 52%) than the other samples, and in females (70.6%) than males (29.4%) (female: male ratio of about 2.4:1). Antibiotic susceptibility of K. pneumoniae against 12 commonly used antibiotics was determined through the disc-diffusion method. The results revealed a higher resistance rate in 51 isolates (100%) against Cephalexin, followed by Ceftazidime (50, 98%), while the lowest resistance rate (24, 47%) was against each of Imipenem and Meropenem. Also, the investigation of the minimum inhibitory concentration (MIC) of Colistin using E-test (strips) demonstrated that 33 isolates were resistance, as compared to 31 using the disk diffusion assay. DNA was extracted from K. pneumoniae isolates and molecularly tested using polymerase chain technique (PCR) with a specific primer and 108 bp product to detect the rpoB gene that represents this bacteria . Also, all of the 51 isolates of K. pneumoniae identified by the rpoB gene were detected for the expression of the Colistin drug resistance gene mgr-B , which was amplified (347 bp) using a specific primer. Colistin resistance gene mgr-B was amplified and sequenced from the twenty isolates. Only 6 isolates appeared with a single nucleotide substitution; G instead A, A instead G, C instead G and G instead C. Also, this study tested biofilm formation from K. pneumoniae isolates , using the microtiter plate method, in association with Colistin and Carbapenem resistant. The Colistin and Carbapenem resistance pattern was compared to the ability of biofilm-formation as weak formation versus strong and also, Multi-drug resistant isolates were more common among weak versus strong biofilm formers.
The melting duration in the photovoltaic/phase-change material (PV/PCM) system is a crucial parameter for thermal energy management such that its improvement can realize better energy management in respect to thermal storage capabilities, thermal conditions, and the lifespan of PV modules. An innovative and efficient technique for improving the melting duration is the inclusion of an exterior metal foam layer in the PV/PCM system. For detailed investigations of utilizing different metal foam configurations in terms of their convective heat transfer coefficients, the present paper proposes a newly developed mathematical model for the PV/PCM–metal foam assembly that can readily be implemented with a wide range of operating condition
... Show MoreWe aimed to obtain magnesium/iron (Mg/Fe)-layered double hydroxides (LDHs) nanoparticles-immobilized on waste foundry sand-a byproduct of the metal casting industry. XRD and FT-IR tests were applied to characterize the prepared sorbent. The results revealed that a new peak reflected LDHs nanoparticles. In addition, SEM-EDS mapping confirmed that the coating process was appropriate. Sorption tests for the interaction of this sorbent with an aqueous solution contaminated with Congo red dye revealed the efficacy of this material where the maximum adsorption capacity reached approximately 9127.08 mg/g. The pseudo-first-order and pseudo-second-order kinetic models helped to describe the sorption measure
Background: Marginal adaptation is critical for long – term success of crown and bridge restoration. Computer aided design / computer aided manufacture (CAD/ CAM) system is gaining more importance in the fabrication of dental restoration. Objective: The aim of this study is to evaluate the effect of crystallization firing on the vertical marginal gap of IPS. emax CAD crowns which fabricated with two different CAD/CAM systems .Materials and Methods: Twenty IPS e.max CAD crowns were fabricated. We had two major groups (A, B) (10 crowns for each group) according to the CAD/CAM system being used: Group A: fabricated with Imes - Icore CAD/CAM system; Group B: fabricated with In Lab Sirona CAD/CAM system. Each group was subdivided into two s
... Show More