A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100μl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5 mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9994 while the percentage linearity (r2%) was 99.88%. The method was applied successfully for the determination of folic acid in pharmaceutical preparation. RSD% for 8 mmo.L-1 (n=6) less than 1% . Using paired t-test it was shown that there was no significant difference between the proposed method and official method (Quoted value- 5mg) and on that basis the new method can be accepted as an alternative analytical method.
The current study is concerned over the benefits from our Prophet ' Surah , these benefits are seven which are : the first : ( The losing , disappointment , weakness in the affairs of those disbelievers ,the second : showing the affairs of the believers in respect to integrity , forgiveness and rest, the third : Indicating the big difference between the believers and disbelievers , each team has his own characteristics that being distinguished from the other, I have explained the benefit that the disbelievers are in a difficult
... Show MoreThe research aims to identify the relationship between spatial ability and the physical structure of concepts to the students of the Faculty of Education for Pure Sciences / Ibn al-Haitham، research involved students from the third class / morning study for the year 2011/2012 totaling (98) male and female students ،distributed into three groups which were selected randomly . The number of students (26 males and females) represented research sample after excluding repeaters and absentees، the research included two tests ; one test of spatial ability، which included (20) items and other test the physical structure of concepts، which included (12) items distributed into four domains ، the first (linking b
... Show MoreThis search include the synthesis of some new 1,3-oxazepine derivatives have been prepared, starting from reaction of L-ascorbic acid with dry acetone in presence of dry hydrogen chloride afforded the acetal (I). Treatment of the latter with p-nitrobenzoyl chloride in dry pyridine yielded the ester (II) which was dissolved in (65%) acetic acid in absolute ethanol yielded the glycol (III). The reaction of the glycol (III) with sodium periodate in distilled water at room temperature produced the aldehyde (IV). The compound (V) [2-amino-5-mercapato-1,3,4-thiadiazole] was prepared through the reaction of thiosemicarbazide with carbon disulphide (CS2) in entity of anhydrous (Na2CO3) in (abs. ethanol ). Compound (VI) [2-(5-mercapto-1,3,4-thiadiaz
... Show MoreBackground: human paillomavirus infections (genital warts) are the most frequent sexually transmitted viral infections. a wide range of treatment options is available with different efficacy.
Objective: To evaluate the efficacy of podophyllin, trichloracetic acid (TCA) in the treatment of genital warts and side effects of them.
Subjects and methods: a total of sixty patients with genital warts were randomly selected, 30 in each group, in the Department of Dermatology, medical city for a Duration of 11 months from January 2009 to December 2009 treated with 35 % podophyllin in the tincture of benzoin or 50% TCA) .Forty-eight patients were followed up for three months.
Results: wart
... Show MoreIn this paper, preliminary test Shrinkage estimator have been considered for estimating the shape parameter α of pareto distribution when the scale parameter equal to the smallest loss and when a prior estimate α0 of α is available as initial value from the past experiences or from quaintance cases. The proposed estimator is shown to have a smaller mean squared error in a region around α0 when comparison with usual and existing estimators.
This study aims to derive a general relation between line loads that acting on two-way slab system and the equivalent uniformly distributed loads. This relation will be so useful to structural designer that are used to working with a uniformly distributed load and enable them to use the traditional methods for analysis of two-way systems (e.g. Direct Design Method). Two types of slab systems, Slab System with Beams and Flat Slab Systems, have been considered in this study to include the effect of aspect ratio and type of slab on the proposed relation. Five aspect ratios, l2/l1 of 0.5, 0.75, 1.0, 1.5 and 2.0, have been considered for both types of two-way systems.
All necessary finite element analyses have been executed with SAFE Soft
Two new halogenated azo-Schiff ligands were prepared in two steps. The first step included a condensation between 4-amino acetophenone and 2-fluoro-4-bromo aniline to give the corresponding Schiff base. In the second step, the diazonium salt of this Schiff base reacted with 2-naphthol and 4,5-diphenylimidazole to form two new azo-Schiff base derivatives as ligands; (3-((E)-(4-((E)-1-((4-bromo-2-fluorophenyl) imino)ethyl) phenyl) diazenyl) naphthalen-2-ol (HSBAN) (L1) and ((E)-N-(4-bromo-2-fluorophenyl)-1-(4-((E)-(4,5-diphenyl-1H-imidazol-2-yl)diazenyl) phenyl) ethan-1-imine) (HSBAI) (L2), respectively. These new ligands were characterized by mass spectrometry, FT-IR, 1H NMR, UV-Visible spectroscopy and elemental microanalysi
... Show MoreThe risk assessment for three pipelines belonging to the Basra Oil Company (X1, X2, X3), to develop an appropriate risk mitigation plan for each pipeline to address all high risks. Corrosion risks were assessed using a 5 * 5 matrix. Now, the risk assessment for X1 showed that the POF for internal corrosion is 5, which means that its risk is high due to salinity and the presence of CO, H2S and POF for external corrosion is 1 less than the corrosion, while for Flowline X2 the probability of internal corrosion is 4 and external is 4 because there is no Cathodic protection applied due to CO2, H2S and Flowline X3 have 8 leaks due to internal corrosion so the hazard rating was very high 5 and could be due to salinity, CO2, fluid flow rate
... Show More