In this paper, the air pollutants concentrations measurements such as Total
Suspended Particles(TSP), Carbon Monoxides(CO),Carbon Dioxide (CO2) and
meteorological parameters including temperature (T), relative humidity (RH) and
wind speed & direction were conducted in Baghdad city by several stations
measuring numbered (22) stations located in different regions, and were classified
into (industrial, commercial and residential) stations. The results show that the
concentrations of pollutants (TSP, CO, and CO2) have exceeded the air quality
standards set by World Health Organization (WHO) and Iraqi limitation in the
stations of the Baghdad city. The program (ArcGIS) used to prepare maps of air
pollution in Baghdad city, as well as MS Excel used for drawing the concentrations
of pollutants in ground and to show changed the concentrations with altitude.
Aircraft measurements of gaseous pollutants including ozone (O3), Carbone
monoxide (CO) , Carbone dioxide (CO2) and the particulate matter concentrations (
PM10 , PM2.5 ) were conducted in the Baghdad city from ( 2 January 2014 to 4
Mars 2014 ),the data of total 10 flight (22 h flight time ),the vertical profile of (CO
,CO2 ,O3 ,PM10and PM2.5 ) have been obtained at different altitude over the
Baghdad city covering the lowermost troposphere up to 2100 feet altitude above
ground level (AGL) during all flights were obtained by A bell 407 aircraft and A
king aircraft. The objective was to characterize the spatial and vertical distributions
of these air pollutants.The results indicate that the air pollution levels were severe
over the Baghdad city. The pollutants concentrations were generally decreasing
with altitude in the boundary layer in the flight measurements .These results are
valuable for studying vertical distribution characteristics of gaseous pollutants and
particulate matters in the boundary layer over the Baghdad city and for providing
important basic data to environmental assessment and decision-making. The reasons
for this increasing due to increase in anthropogenic emissions, mainly due to the
increase in fossil fuel use for heating, the burning of the fuel used in various types
of vehicles, as well as the low quality of fuel and the age of the vehicles, the use of
generators, the dry climate, soil erosion, lack of roadside vegetation, paved areas,
substantial rise in number of vehicles and poorly maintained vehicles have all been
held Responsible.
Heat island is known as the increases in air temperature through large and industrial cities compared to surrounding rural areas. In this study, remote sensing technology is used to monitor and track thermal variations within the city center of Baghdad through Landsat satellite images and for the period from 2000 to 2015. Several processors and treatments were applied on these images using GIS 10.6 and ERDAS 2014, such as image correction and extraction, supervised classification, and selection of training samples. Urban areas detection was resulted from the supervised classification linked to the temperature readings of the surface taken from the thermal bands of satellite images. The results showed that the surface temperature of the c
... Show MoreFor cleaner air and unpolluted continue assessment study air pollution the city of
Baghdad by measuring the concentrations of air pollutants, which included TSP, Pb, where
the adoption of three stations (Andalus Square, Jadiriya, Allawi) are distributed in the city of
Baghdad in order to compare the concentrations of these pollutants with previous studies.
Study pointed out that the city's air contaminant, especially in minutes outstanding after
deducting the amount of atmospheric dust thick mechanism city this year where the highest
concentration of minutes outstanding (9895) micrograms / m 3 at the station Alawi and lower
concentration of 157 micrograms / m 3 at the station Alawi and this was higher than the
det
The phenomenon of young people frequenting closed cafes spread in Baghdad to smoke hookahs and cigarettes has increased. This phenomenon is associated with unemployment, an increase in leisure time and the deterioration of economic conditions. This phenomenon has an impact on indoor air quality and exposes workers to the risk of exposure to various pollutants, including particulate matter, therefore, we examined some indicators (PM2.5, PM10) IAQ for a month in summer and another month in winter in six different locations in the Rusafa district. PM2.5 and PM10 concentrations, relative humidity (RH) and temperatures were measured using (Multifunction Air Quality Detector BENETECH -China). The results showed an increase in temperatures inside
... Show MoreRoughness length is one of the key variables in micrometeorological studies and environmental studies in regards to describing development of cities and urban environments. By utilizing the three dimensions ultrasonic anemometer installed at Mustansiriyah university, we determined the rate of the height of the rough elements (trees, buildings and bridges) to the surrounding area of the university for a radius of 1 km. After this, we calculated the zero-plane displacement length of eight sections and calculated the length of surface roughness. The results proved that the ranges of the variables above are ZH (9.2-13.8) m, Zd (4.3-8.1) m and Zo (0.24-0.48) m.
The ground level ozone concentration at different locations in Baghdad city was identified. Five
different sites have been chosen to identify the ground level ozone concentration. Al- Dora and Al-
Za'afarania were chosen as areas contained point source ( power plant station ) in addition to high traffic
load , while Al –Uma park, Aden square and Al-Mawal square were chosen as area contained heavy
traffic only (line source). The measurement focuses on spring and fall because these periods display
favorable meteorology to ozone formation. During the research period the maximum values (peaks) for
ground level ozone concentration were observed at fall: at Al-Za'afarania area 101ppb as an average, at
Al-Dora 87 ppb as a
When the number of confirmed coronavirus disease cases rose in Iraq in the middle of February 2021, the Iraqi government performed a closure approach to constrain mobility and factory operations and enforce social distancing. In this research, the concentrations of air components (PM2.5, PM10, nitrogen dioxide (NO2) and ozone (O3)), which represent herein the degree of air quality index, were recorded, drawn and evaluated over central (Baghdad, the capital), northern (Kirkuk Province) and southern (Basra Province) Iraq before and during the closure. The experimental duration of this research was 6 months (from 1 January 2021 to 30 June 2021), which
... Show MoreEmissions of particulate matter from nanopapers as well as inks and organic solvents during the printing operationand copying machines constitute a threat to human health, especially with long time exposure in closed working environments. The present study was conducted in some printing houses and copying centers of Baghdad city during February and April .The studyproved the occurrence of an air pollution problem concerning lead and zinc contents in all the study sites. The levels of Pb, Zn and Cu were collected by low volume sampler from the air of the study sites then filter papers digested and determined the heavy metals by flame atomic spectrophotometer. Particulate matter was measured by Aerocet, Microtector meter device was use
... Show MoreIn the present work, radon gas concentrations in different surface soil samples in Baghdad governorate were measured using RAD-7 detector. The results have been shown that, the Radon gas concentrations ranged between (41.67±1.78Bq/m3), to (185.67±4.22Bq/m3), a map showing the distribution of the concentration of radon in selected areas was defined to identify areas with high pollution level. The reason for the high concentration of radon is that these surface soil samples are taken from agricultural areas. It is also known that fertilizers contain uranium levels as well as areas bombed in wars in the country. It is worth noting that all radon concentrations in Baghdad governorate are below the recommended minimum of 200-300Bq/m3) (Inte
... Show MoreIn this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average valu
This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, satura
... Show More