In this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average value
3.354mSv/y, and 852 to 2951 with an overall average value 2013,
respectively. For thoron gas only, the results showed that the thoron
activity concentration varied from 15.05 to 172.40 Bq/m3 with an
overall average 76.48 Bq/m3, and 0.021to 0.240for WLM with an
overall average 0.106, respectively. The values of Eff and ELC have
been found to vary from 0.256 to 2.94 mSv/y with an overall
average1.30 mSv/y and from 57 to 652 with an overall average of
298, respectively. The concentration of radon progeny varied from
59.44 to 301.39 Bq/m3 with an overall average 157.62 Bq/m3. The
results illustrated that there is a large variation in the values of the
measured concentrations. This is due to the wide variation in the
construction of the houses in Al-Madaan city. However, all
investigated locations have radon concentration below the action
level (200-300Bq/m3) that recommended byICRP. Therefore, there is
no health hazard of radon in the region of Al-Madaan city where
measurements have been performed.
This work represents the set of measurements of radon and thoron concentrations levels of soil-gas in Al-Kufa city in Iraq using electric Radon meter (RAD-7). Radon and thoron concentration were measured in soil-gas in 20 location for three depth of (50, 100 and 150) cm.
The results show that the emanation rate of radon and thoron gas varied from location to anther, depending on the geological formation. The Radon concentration in soil has been found to vary from (12775±400) Bq/m3 at 150 cm depth in location (sample K2) to (41.45±17) Bq/m3, for depth 150 cm in location (sample K20). The thoron concentration in soil has been found to vary from (198±8.5) Bq/m3 at 150 cm depth in location samples (K1 & K2) to undetected in the mos
In this study, radon concentrations were measured in dwellings at specified locations in Baghdad city using ionization chamber radon monitor (ALPHA GUARD PQ2000 PRO). The measurements were carried out at different locations of these dwellings (living rooms, bed rooms, bath rooms, and kitchens). The results of the survey showed that the overall minimum, maximum average and mean average radon concentrations in dwellings were 5.77±0.73 Bq/m3, 23.27±13.57 Bq/m3, and 10.67±4.14 Bq/m3 respectively. The lowest average radon was found in (Ameryia) city, while the highest average radon concentration was found in (Kadmiya) city. Also, the results showed that the highest average radon concentration was found in the kitchens, while the lowest ave
... Show More
Measurement of radon concentration level was carried out in 40 houses in Al – Najaf city during summer season of 2012. Long term measurement of indoor of old building radon concentrations have been taken, using a previously calibrated passive diffusion dosimeters containing CR – 39 solid state nuclear track detectors which are very sensitive for alpha particles. The measurement of the indoor radon concentration obtained in summer in these regions ranged from 11.654±4.216 Bq.m-3 to 53.610±8.777 Bq.m-3. The results were within universally permitted levels. |
In the present work, radon gas concentrations in different surface soil samples in Baghdad governorate were measured using RAD-7 detector. The results have been shown that, the Radon gas concentrations ranged between (41.67±1.78Bq/m3), to (185.67±4.22Bq/m3), a map showing the distribution of the concentration of radon in selected areas was defined to identify areas with high pollution level. The reason for the high concentration of radon is that these surface soil samples are taken from agricultural areas. It is also known that fertilizers contain uranium levels as well as areas bombed in wars in the country. It is worth noting that all radon concentrations in Baghdad governorate are below the recommended minimum of 200-300Bq/m3) (Inte
... Show MoreThe phenomenon of young people frequenting closed cafes spread in Baghdad to smoke hookahs and cigarettes has increased. This phenomenon is associated with unemployment, an increase in leisure time and the deterioration of economic conditions. This phenomenon has an impact on indoor air quality and exposes workers to the risk of exposure to various pollutants, including particulate matter, therefore, we examined some indicators (PM2.5, PM10) IAQ for a month in summer and another month in winter in six different locations in the Rusafa district. PM2.5 and PM10 concentrations, relative humidity (RH) and temperatures were measured using (Multifunction Air Quality Detector BENETECH -China). The results showed an increase in temperatures inside
... Show MoreIn this work, radon concentrations in the polluted environment were measured within the Baghdad sample surface soil conservation, and this was done using a RAD-7 mobile detector. The work consists of four parts:
The first part includes calculating the latitude and longitude of each point of the study area using the Global Positioning System (GPS). The second part of which includes Determination of 222Rn gas concentrations in surface soil samples. In the northeast part of Baghdad, the highest concentration of radon was found in Al-
Shaab area (3.11 ±175.33 Bq / m3), while the lowest gas concentration in AL Gzeera area (6.67±73.00 Bq/ m3), In the northwest part of Baghdad, the highest concentratio
The present work aims to investigate approaches, measures and detection of indoor radon level in buildings of the department of physics in college of science of Baghdad University. CR-39 solid state nuclear track detectors were used to measure the radon concentrations inside the rooms, including five laboratories and five workplace rooms in ground and first storey of the department. The average radon concentration at first storey was found to be 43.1±13.2 Bq/m3 and 40.1±13.4 Bq/m3 at the ground storey. The highest level of radon concentration at the first storey in the radioactive sources store was 87.5±29 Bq/m3 while at the ground storey in room(2) was 70.2±24 Bq/m3 which is due to the existence radioactive sources in some selected
... Show MoreIn this research the activity of radon gas in air in Baghad governorate,Iraq, using “alpha-emitters track registration (CR-39) track detector were measured. This measurement was done for selected areas from Baghdad Governorate, The results obtained shows that the highest average concentrations for Rn-222 is (179.077 Bq/m^3) which was recorded within Al-Shaaib city and less average concentrations was (15.79 Bq/m^3) in the nearby residential area of Baghdad International Airport and the overall average concentrations is (86.508 Bq/m^3) for these regions. Then the radon concentration was measured annual effective dose calculated from radon concentration and found in range from 0.4031 mSv/y to 4.5179 mSv /y with an average value of 2.1824 m
... Show More