In this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average value
3.354mSv/y, and 852 to 2951 with an overall average value 2013,
respectively. For thoron gas only, the results showed that the thoron
activity concentration varied from 15.05 to 172.40 Bq/m3 with an
overall average 76.48 Bq/m3, and 0.021to 0.240for WLM with an
overall average 0.106, respectively. The values of Eff and ELC have
been found to vary from 0.256 to 2.94 mSv/y with an overall
average1.30 mSv/y and from 57 to 652 with an overall average of
298, respectively. The concentration of radon progeny varied from
59.44 to 301.39 Bq/m3 with an overall average 157.62 Bq/m3. The
results illustrated that there is a large variation in the values of the
measured concentrations. This is due to the wide variation in the
construction of the houses in Al-Madaan city. However, all
investigated locations have radon concentration below the action
level (200-300Bq/m3) that recommended byICRP. Therefore, there is
no health hazard of radon in the region of Al-Madaan city where
measurements have been performed.
The aim of this work is to determine radon and its decay product concentratiQns indoor and outdoor in different areas in north and middle are·a of Iraq by using nuclear trak detectors , CR-39 , CN- 85 andLR-115. -
For CR-39 detectors , the highest radon concentration was
(64.07Bq/m3)indoor and (52.4 Bq/m3)
outdoor &n
... Show MoreIn the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon
Radon is the most dangerous natural radioactive component affecting the human population, since it is a radioactive gas that results from the decomposition process of uranium deposits in soil, rocks, and water, and it is damaging both humans and the ecosystem. The radon concentrations and exhalation rate in soil samples from various locations were determined using a passive approach with a CR-39 (CR-39 is Columbia Resin #39; it is allyl diglycol carbonate C12H18O7) detector in Amiriya region in Baghdad Governorate. The average values of radon concentrations are ranged from 47.3 to 54.2 Bq·m−3. From the obtained results, we can conclude that the values of all studied locations are
In the present work , radon concentration was measured indoor buildings in the College of Education for Pure Science/ Ibn Al- Haitham University of Baghdad using detector (CR-39) by counting track of alpha resulting from decay series of uranium on the detectors which have exposure to air inside the rooms for (30) days , have been applied the equation (1) and (2) to calculate concentrations of Radon and the results showed that all samples were within the allowable range globally except two samples F1 and F2 where concentrations were (445.868Bq/m3) and (436.791Bq/m3) respectively , they were higher than allowable range globally which was (200-300) Bq/m3 recorded by (ICRP) [1] .
This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in the study were
... Show More