Various types of storing tanks are used to store municipal water at homes. This study was carried out to examine several water physical and chemical variables such as pH, EC, TSS and TDS after different storing periods. The obtained results showed no significant differences between the mean of pH values which ranged from 7.27 ± 0.04 in a water sample of galvanized tank after six days of storing to 8.10 ± 0.12 in water sample of aluminum tank after nine storing days. In case of electric conductivity, Highest mean values (1.85±0.09 μS/cm and 1.44 ± 0.21μS/cm) were found in galvanized tank samples for different storing periods while the lowest mean values (0.58±0.06 μS/cm and 1.04±0.06 μS/cm) were recorded in aluminum tank samples. However in plastic tanks samples, the mean values were moderated (0.94 ±0.05 μS/cm and 1.16±0.03 μS/cm) between means of both tanks. In case of TSS, the current data have shown significant differences between mean values of examined stored water samples where highest values (730.0±31.97 mg/l - 1060.0±141.42 mg/l) were in galvanized tank water samples and the lowest mean values (27.67±21.36 mg/l – 118.33 ±18.46 mg/l) were in plastic tank water samples whilst in aluminum tank water samples, these values were varied from 193.33±10.66 mg/l – 253.33±22.2 mg/l). In general, only water samples stored in galvanized tank had mean value significantly higher that of control sample which had 251.33±3.21 mg/l. Regarding TDS, this study has found that highest mean values (800.0±40.0 mg/l – 1600.0±100.0 mg/l) were recorded in water samples of aluminum tank and the lowest mean values (40.0±10.0 mg/l – 120.0±10.0 mg/l) were found in water samples of plastic tank while water samples of galvanized tank had mean values varied from 680.0 ±10.0 mg/l – 1172.0 ±18.08 mg/l. Control sample, however had mean value of 495.0±5.0 mg/l which was only higher than that of plastic tank
The purpose of this paper is to give the condition under which every weakly closed
function is closed and to give the condition under which the concepts of weaklysemi
closed function and weakly pre-closed function are equivalent. Moreover,
characterizations and properties of weakly semi closed functions and weakly preclosed
function was given.
Choosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show MoreDenture cleansing is an essential step that can stop cross‑contamination and adds to the health of the patient, denture durability, and the general quality of life. A disinfection technique must be practical and devoid of damaging effects on the material's properties used to construct the denture base. The main aim of this study is to evaluate the effect of three concentrations of electrolyzed water denture cleanser on heat cure acrylic and polyamide after immersion in electrolyzed water. The evaluation is based on their efficacy on surface hardness, wettability, and color stability compared with one submerged in distilled water as a control group. The method consists of eighty samples of heat-cured acrylic and polyamide material.
... Show MoreDissolution of gypsum rock in water is significant, which may result in hydrocarbon reservoir formation and evaporate deposits. However, the complexity of the gypsum dissolution process is still of interest because of its uncleanness that requires more critical analysis. The objectives of this experimental study are emphasis on the dissolution characteristics of gypsum rock under room temperature and by various types of water; namely: deionized, tap, fresh, acidic, well, and normal rainwatre. In addition, the influences of dissolution on gypsum rock's mechanical and physical characteristics. Gypsum rock was obtained from Agjalar area, in the southwest of Sulaymaniyah city, Northern Iraq. Experimental results show that we
... Show MoreThe main objective of this thesis is to study new concepts (up to our knowledge) which are P-rational submodules, P-polyform and fully polyform modules. We studied a special type of rational submodule, called the P-rational submodule. A submodule N of an R-module M is called P-rational (Simply, N≤_prM), if N is pure and Hom_R (M/N,E(M))=0 where E(M) is the injective hull of M. Many properties of the P-rational submodules were investigated, and various characteristics were given and discussed that are analogous to the results which are known in the concept of the rational submodule. We used a P-rational submodule to define a P-polyform module which is contained properly in the polyform module. An R-module M is called P-polyform if every es
... Show MoreElection study included four sites for the waters in area of Youssifiyah south of Baghdad (river water, tank water, liquefactions water, and water filtrate and seethed and purifier by alum and chloride), the samples were collected during the month of June in 2007. Temperature, electrical conductivity and acidity are measured. Also , the concentration of chloride , sulphate , carbonate , nitrate , sodium , calcium , magnesium , hard total and total dissolved substances are determined , as well as heavy metals assess environmental risk (such as Cu, Pb, Zn, Fe). It was also a study of bacterial totals included both total Bacteria (TB) and Total Coliform Bacteria (TC) and Fecal Coliform (FC) and Fecal Streptococci (FS). The stu
... Show MoreThe cartographic representation of geographical phenomenon considers the essential base in geographical analysis since as it supports the vertical house which is apartment houses consist of apartments which represent civil phenomenon , the aim of this study is to project the rule of cartographic representation methods in geographical analysis and make comparison in economic and social aspects for two approaches , the vertical and construction building methods.
The expand of city horizontally represent a problem in itself because it leads to loss of civil lands and overpass the agricultural lands as a result ,the ratio of habitation of land usage is so large in comparison with another usages of lands of the cities ; therefore ; many co
Three hospitals were chosen(Maternity hospital, Raperin hospital and Rhizgari hospital) for the present survey within Erbil city. Water samples were collected at regular monthly interval periods beginning in January 2012 to December 2012. pH of all the studied sites were found to be up 7. Electrical conductivity ranged from (1318-1790 μs.cm-1 in Maternity Hospital, 1770-2232 μs.cm-1 in Raperin Hospital, 1010-1615 μs.cm-1 in Rhizgari Hospital). BOD5 and COD values ranged from 22- 80 mg.L1 and 280- 1410 mg.L-1 respectively, this indicated a high pollution situation in the studied sites in respect to organic matter content. The quantitative analysis of counted microorganisms was more than that describe by WHO guidelines standard.
The study area soils suffer from several problems appear as tkhesvat and cracks in the roads and waterlogging which reduces the susceptibility of soil to withstand pressure, this study was conducted on the soil of the Karkh district based on field study that included (6) samples of soil physical analyses contain different ratios of (mud, sand, silt) as percentages (52%, 45%, 3 #) respectively, and liquidity limit rate (39%) Stroke rate plasticity was (20.6%) The rate coefficient of plasticity total (19.2%)0
In this research, a selection of some mineral water was selected on the basis of being the most marketed by the owners of shops in Najaf province, with six types, where daily samples of this water were taken by 50 ml for two months from (1/11/2018 -1/1/2019). The following ions concentrations were measured (Br-, Cl-, F-, NO3-, SO42-, Na+, K+, Ca2+, Mg2+), pH and the electrical conductivity were measured and the results were compared with the allowable rates according to the international organizations. It was noted that they conform to international and Iraqi standards.