A new mode for an on-line determination of Pyrocatechol, Resorcinol, and Pyrogallol in pure commercial samples using CFIA with homemade Ayah 3SBGRx3- 3D solar cell microphtometer analyzer.

A new, simple, accurate, fast and sensitive spectrophotometric method has been
developed for the analysis of Pyrocatechol, Resorcinol, and pyrogallolin pure
commercial samples by continuous flow injection analysis. The method was based on
the oxidation of the organic compounds with Ce(IV)sulfate in acidic medium to
formed a brown colored species which determined using homemade Ayah 3SBGR x3-
3D solar cell flow injection microphotometer. Optimum conditions were obtained
using a high intensity green light emitted diode as an irradiation source
forPyrocatechol, Resorcinol, whileblue light emitted diode as an irradiation source for
pyrogallol. The linear dynamic range for the instrument response versus Pyrocatechol,
Resorcinol, and pyrogallol concentrationswere5-40mmol.L-1 while the L.O.D was of
36.63, 17.17, and 41.61ng / sample respectively. The correlation coefficient (r) was
0.9952, 0.9970, and 0.9960 while percentage linearity (r2%) was 99.05%, 99.41% and
99.22%forPyrocatechol, Resorcinol, and pyrogallol respectively. RSD% for the
repeatability (n=8,7, and 8) was 1.4%, 0.63%, 1.78% for the determination of
Pyrocatechol, Resorcinol,andpyrogallol, respectively at concentration of 30 mmol.L-1.
The method was applied successfully for the determination of three organic
compounds in purecommercial samples. A comparison was made between the newly
developed method and the classical method (UV-Vis spectrophotometry) at wave
length 492, 481, and 438 nm forPyrocatechol, Resorcinol and pyrogallolrespectively
of analysis using the standard additions method via the use of paired t-test. It was
noticed that there is no significant difference between two different methods for
analysis three different organic compounds; in addition to no significant difference in
the contribution of the Pyrocatechol, Resorcinol and pyrogallol to the oxidant reaction
path, at 95% confidence level.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 22 2019
Journal Name
Baghdad Science Journal
Synthesis and Characterization of New Selenonitrone Derivative and Its Effect on Breast Cancer Cell Line Viability in Vitro

          New nitrone and selenonitrone compounds were synthesized. The condensation method between N-(2-hydroxyethyl) hydroxylamine and substituted carbonyl compounds such as [benzil, 4, 4́-dichlorobenzil and  2,2́ -dinitrobenzil] afforded a variety of new nitrone compounds while the condensation between N-benzylhydroxylamine and substituted selenocarbonyl compounds such as [di(4-fluorobenzoyl) diselenide and (4-chlorobenzoyl selenonitrile] obtained selenonitrone compounds. The condensation of N-4-chlorophenylhydroxylamine with dibenzoyl diselenide obtained another type of selenonitrone compounds. The structures of the synthesized compounds were assigned based on spectroscopic data (FT-IR,

... Show More
Scopus (3)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Fri Oct 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Novel Approach of CFIA Technique for Assaying of Furosemide (Sulfa Drug) as Antibacterial Agent in Pharmaceutical and Biological Samples Using Potassium Ferricyanide as Oxidizing Agent

Furosemide drug determination in pharmaceutical and biological urine samples using a novel continuous flow-injection analysis technique that is simple, rapid, sensitive and economical. The complex formed by the reaction of furosemide and O-phenylenediamine with oxidative agent K3[Fe(CN)6] to produce an orange-yellow colored product at 460 nm was the basis for the proposed method.  The proposed method’s linearity ranges (3-100) μg.mL-1and (1-50) μg.mL-1 for CFIA/merging zone methods and batch .The detection limit and Limit of quantification values were 2.7502 μg.mL-1  and 9.1697 μg.mL-1 the relative standard deviation was 0.7143 %, and the average recovery is 98.80%

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Construction of New Ion Selective Electrodes for Determination Fe(III) and Their Application in Pharmaceutical samples

Liquid membrane electrodes for the determination iron(III) were constructed based on chloramphenicol sodium succinate and iron(III) CPSS-Fe(III) as ion pair complex, with four plasticizers Di-butyl phosphate (DBP); Di-butyl phthalate (DBPH); Di-octyl phthalate (DOP); Tri-butyl phosphate (TBP); in PVC matrix . These electrodes give Nernstian and sub-Nernstian slopes (19.79, 24.60, 16.01 and 13.82mV/decade) and linear ranges from (1x10-5-1x10-2 M, 1x10-5-1x10-2 M, 1x10-6-1x10-2 M and 1x10-5-1x10-2 M) respectively. The best electrode was based on DBP plasticizer which gave a slope 19.79 mV/decade, correlation coefficient 0.9999, detection limit of 9×10-6 M, lifetime 37 day displayed good stability and reproducibility and used to determine

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Chemiluminometric- CFIA for the Determination of Cobalt (ll) Ion in Commercial Cobalt-Molybdenum Catalyst (K F124-3E) Used in Desulphurization Processes of Petroleum Products via Multi Gel Beads Reactor.

Co(II) ion was determined by a new, accurate, sensitive and rapid method via a
continuous flow injection analysis (CFIA) with a chemiluminescence reaction based on
the oxidation of Luminol which is loaded on poly acrylic acid gel beads by hydrogen
peroxide in presence of Cobalt (II) ion as a chemiluminescence catalyst. Chemical and
physical parameters were investigated to obtain the best conditions. Linear dynamic
range of Cobalt (II) ion was from 0.1-20.0 μg.ml-1 with a correlation coefficient r =
0.9758, limit of detection (L.O.D) 0.2 ng/sample from the step wise dilution of lowest
concentration in the calibration graph with the percentage relative standard deviation for
3 μg.ml-1 Co(ll) solution is 0.8537% (n

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Two Spectrophotometric Methods Based on Diazotization Coupling Reaction for Determination of Genistein in Pure and Supplement

      Genistein (GEN) is one of the predominant dietary isoflavones found in legumes such as soybeans. Genistein has been recommended as an osteoporosis treatment for postmenopausal women and elderly men, with the intention of reducing cardiovascular disease and hormone-dependent malignancies. Therefore, two sensitive and simple methods for quantifying it in the supplements preparation were developed.The first method (A) comprised employing the surfactant Triton X-114 to extract the result of the diazotization reaction with 4-Aminoacetophenone(4AMA) utilizing a cloud point extraction technique. The product was extracted using micelles of a non-ionic surfactant (TritonX-114) and then spectrophotometrically detected at a specified wa

... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
View Publication Preview PDF
Publication Date
Thu May 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using Gamma Ray Transmission for Determination of Porosity in Doped Alumina Samples

     In this study, gamma ray transmission method have been used to determine the total porosity in four samples: pure Alumina  ( Al2O3   ),  Al2O3 + (0.2wt%)MgO ,  Al2O3 + (0.6wt% )Y2O3  and Al2O3+ (8wt% ) ZrO2 .

      The experimental setup for the gamma ray transmission consist of 137Cs gamma source ( 662 KeV  ), a  NaI (Tl) scintillation detector measured the attenuation of strongly collimated  gamma beam through alumina samples.

The porosity obtained by the gamma ray transmission method were compare

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Synthesis New Liquid Selective Electrodes of Ciprofloxacin Hydrochloride for Determination Ciprofloxacin in Pure form and Pharmaceuticals Preparation.

New membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0

... Show More
Scopus (8)
Scopus Crossref
View Publication Preview PDF
Publication Date
Wed May 30 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Indirect Way for the Assay of Captopril Drug in Dosage FormsUsing1,10-Phenanthroline as a Selective Spectrophotometric Agent for Fe(II) Via Homemade CFIA /Merging Zones Technique

        A new speed and sensitive batch and merging zones-flow injection analysis spectrophotometric ways for estimation of captopril in a fine material and in pharmaceutical formulations were suggested. The procedure was depended on the  decline of Fe(III) as FeCl3 to Fe(II) by captopril in acetic acid as medium, the produced Fe(II) interplays with 1,10-phenanthroline to compose a soluble orange-red colored product that is determined at maximum wave length of 511nm. The manifold FIA system was able to determine of CPL. with a throughput 51 sample/h. Calibration curves of absorbance against concentration sign of that Beer, s law is submitted to within the concentration scale o

... Show More
Crossref (2)
Crossref
View Publication Preview PDF
Publication Date
Sun Apr 29 2018
Journal Name
Iraqi Journal Of Science
FIA– Spectrophotometric methods for the determination of Naringenin in supplements and urine samples using diazotization coupling reactions

Direct FIA methods for estimation of Naringenin (NG) in different samples were proposed. These methods are based on diazotization coupling reactions of two reagents: method (A) p-chloroaniline (PCA) and method (B) procaine hydrochloride (PRH) with NG in basic medium. Yellow dyes with maximum absorption at 416 and 415 nm were formed respectively. Calibration curves were constructed over different NG concentrations, linearity was from 1- 70 and 1- 40 µgmL-1 with detection limits of 0.55 and 0.24 µgmL-1 for (A) and (B) respectively. All analytical variables involved in the FIA procedure were evaluated and optimized. The established methods were successfully applied for the determination of NG in its supplements and u

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with 4-(2-pyridylazo) Resorcinol-Application to Waters and Veterinary Preparation

This paper describes the development of a simple spectrophotometric determination of bismuth III with 4-(2-pyridylazo) resorcinol (PAR) in aqueous solution in the presence of cetypyridinium chloride surfactant at pH 5 which exhibits maximum absorption at 532 nm. Beer's law is obeyed over the range 5-200 µg/25 mL. i.e. 0.2-8 ppm with a molar absorptivity of 3×104 l.mol-1.cm-1 and Sandell's sensitivity index of 0.0069 µg.cm-2. The method has been applied successfully in the determination of Bi (III) in waters and veterinary preparation.

Crossref
View Publication Preview PDF