Shisha smoke represents one of the causes of indoor air pollution. Heavy metals represent the main components in shisha smoke. In this research study, the indoor concentrations of heavy metals in shisha smoke café sites was investigated, samples were taken from two café sites (site1, site 2) which differ in their volume. Site1 volume was 77m3, while site 2 was 437.5m3. Sample were taken by using a low volume sampler (sniffer), and then examined by the Atomic Absorption Spectrometry (AAS). The results showed that indoor air shisha smoke samples for both experimental sites have shown a significant amount of heavy metals as compared with control sampling values. The mean concentration values of (Pb, Zn, Co, Ni, Cr) in site 1 were (11.004, 9.544, 24.088, 19.84, 24.98 μg/m3) respectively, while the mean concentration values of these heavy metal in site 2 were (5.574, 6.578, 16.684, 26.114, 9.636 μg/m3) respectively. Results and conclusions referred those indoor air concentrations during shisha smoking times were high and exceed the WHO standard limits
This study deals with the shallow alluvial aquifer situated beneath the urban area of kirkuk city. The ancient part of the city (Shorja) is affected by seepage from local agricultural areas causing relatively high heavy metals concentration in groundwater. The selection of polluted site depended on the highest TDS value (3856 mg/L) associated with the highest heavy metal concentrations (Pb, Ni, Co and Zn) in groundwater. This study focuses on the evaluation of natural attenuation effectivity for long-term protection of groundwater quality using realistic three-dimensional reactive-transport groundwater model. The requirements of 3-dimensional reactive transport model were obtained from field observation and laboratory works, in addition
... Show MoreSwabs from two hospitals at Baghdad city were collected from the period 28-October-2013 to 31-March-2014, to found out the prevalence and distribution of fungi. These isolates were collected from hospitals' environment and most of the items used for hospital work in order to detect the nosocomial pathogens persistent. All fungal isolates were identified depending on the morphological and microscopic examinations as well as biochemical tests. Out of 220 environmental samples, 146 fungal isolates was obtained, Aspergillus flavus was more frequency and occurrence 23.29% and 15.45% respectively, followed Aspergillus niger was 15.57% and 10.45% then Penecillium spp. was 13.27% and 8.64%. In Al -Yarmouk Teaching Hospital more places contaminat
... Show MoreModern cities suffer from heavy metal pollution due to urban expansion and population increase. Heavy metals have a great impact on human health. The objective is to determine the contamination level of heavy metals Cr, Mn, Ni, Cu, Zn, As, Zr and Pb at industrial and residential in Hilla city. The mean concentration of Cr, Mn, Ni, Cu, Zn, As, Zr and Pb enrichment factors of the investigated industrial soils are 3.43, 0.74, 6.45, 3.95, 5.60, 3.44, 1.17 and 11.44, respectively. The means of Cr, Mn, Ni, Cu, Zn, As, Zr and Pb in residential soils are 3.30, 1.09, 11.40, 0.94, 2.08, 5.39, 0.9 and 3.6, respectively. The I-geo mean values of heavy elements in the industrial area may be ordered in the following: Mn> Pb> Ni>
... Show MoreThe present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water
... Show MoreIn the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the rang
This work involves hard photon rate production from quark -gluon plasma QGP interaction in heavy ion collision. Using a quantum chromodynamic model to investigate and calculation of photons rate in 𝑐𝑔 → 𝑠𝑔𝛾 system due to strength coupling, photons rate, temperature of system, flavor number and critical. The photons rate production computed using the perturbative strength models for QGP interactions. The strength coupling was function of temperature of system, flavor number and critical temperature. Its influenced by force with temperature of system, its increased with decreased the temperature and vice versa. The strength coupling has used to examine the confinement and deconfinement of quarks in QGP properties and inf
... Show MoreIn this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p
... Show MoreThis study was conducted to detect the concentration of lead and cadmium in baby foods, (18) samples were examined, which are the most available from various local markets in the city of Baghdad (at a rate of (9) samples of baby food consisting of cereals and (9) samples of baby foods consisting of vegetables). All samples were examined using an atomic flame absorptiometry (AAS-7000), all results showed the presence of lead and cadmium and the highest concentration value of lead in baby foods consisting of cereals (1.0986) and cadmium in baby foods consisting of vegetables (0.0015) ppm. Lead exceeded 100% limitations and cadmium did not exceed that. The results reported on the risks of contamination, as the mean daily intake (g/kg/d) for
... Show MoreExperimental and numerical studies have been conducted for the effect of injected air bubbles on the heat transfer coefficient through the water flow in a vertical pipe under the influence of uniform heat flux. The investigated parameters were water flow rate of (10, 14 and 18) lit/min, air flow rate of (1.5, 3 and 4) lit/min for subjected heat fluxes of (27264, 36316 and 45398) W/m2. The energy, momentum and continuity equations were solved numerically to describe the motion of flow. Turbulence models k-ε was implemented. The mathematical model is using a CFD code Fluent (Ansys15). The water was used as continuous phase while the air was represented as dispersed. phase. The experimental work includes design, build and instrument a test
... Show MoreThe aim of this study is to determine the level of pollution with heavy metals (Cd, Cr, Cu, Ni, Pb, Zn) and their potential sources in dust samples collected from schools in Ramadi City, Iraq. The dust samples were collected from 40 primary schools and two kindergartens and analyzed by using atomic absorption spectrophotometer. The heavy metal concentrations were found to follow the order Cr > Cu > Pb > Ni > Zn > Cd. The results indicated that the concentrations of Cd, Cu, and Pb exceeded the permitted background values. The pollution level was assessed using the geo-accumulation index (Igeo) and pollution load index (PLI). The classification of dust samples according to Igeo values showed that
... Show More