Preferred Language
Articles
/
ijp-268
Indoor risk assessment of radon gas in the science college buildings-University of Mustansiriyah using RAD-7 detector
...Show More Authors

In the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the range 3-10 mSv/y [ICRP, 1993]. While the values of lung cancer cases per year per million person vary from 4.50 per million person to 42.84 per million person with an average value 24.35±12 per million person which is lower than the recommended range 170-230 per million person [ICRP, 1993].
The values of the potential alpha energy concentration were found to vary from 10.18 mWL to 1.06 mWL, with an average value 5.79±2.8 mWL which is lower than the recommended value of 53.33 mWL given by [UNSCEAR, 1993].

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 14 2021
Journal Name
Iraqi Journal Of Physics
Measurement of radon and thoron concentrations of soil- gas in Al-Kufa city using RAD-7 detector
...Show More Authors

This work represents the set of measurements of radon and thoron concentrations levels of soil-gas in Al-Kufa city in Iraq using electric Radon meter (RAD-7). Radon and thoron concentration were measured in soil-gas in 20 location for three depth of (50, 100 and 150) cm.
The results show that the emanation rate of radon and thoron gas varied from location to anther, depending on the geological formation. The Radon concentration in soil has been found to vary from (12775±400) Bq/m3 at 150 cm depth in location (sample K2) to (41.45±17) Bq/m3, for depth 150 cm in location (sample K20). The thoron concentration in soil has been found to vary from (198±8.5) Bq/m3 at 150 cm depth in location samples (K1 & K2) to undetected in the mos

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 12 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement of Radon Concentration in College of Education for Pure Science / Ibn Al- Haitham Buildings Using CR-39 Detector
...Show More Authors

   In the present work , radon concentration was measured indoor buildings in the College of Education for Pure Science/ Ibn Al- Haitham University of Baghdad using detector (CR-39) by counting track of alpha  resulting from decay series of uranium on the detectors which have exposure to air inside the rooms for (30) days , have been applied the equation (1) and (2) to calculate concentrations of Radon and the results showed that all samples were within the allowable range globally except two samples F1 and F2 where concentrations were (445.868Bq/m3) and (436.791Bq/m3) respectively , they were higher than allowable range globally which was (200-300) Bq/m3 recorded by (ICRP) [1] .

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Measurement of Indoor Radon Gas Concentration in same Region of Baghdad Governorate Using CR-39 Nuclear Track Detector
...Show More Authors

In this research the activity of radon gas in air in Baghad governorate,Iraq, using “alpha-emitters track registration (CR-39) track detector were measured. This measurement was done for selected areas from Baghdad Governorate, The results obtained shows that the highest average concentrations for Rn-222 is (179.077 Bq/m^3) which was recorded within Al-Shaaib city and less average concentrations was (15.79 Bq/m^3) in the nearby residential area of Baghdad International Airport and the overall average concentrations is (86.508 Bq/m^3) for these regions. Then the radon concentration was measured annual effective dose calculated from radon concentration and found in range from 0.4031 mSv/y to 4.5179 mSv /y with an average value of 2.1824 m

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
Measurements of Radon-222 and its Daughters Concentrations in Buildings of Department Physics in College of Sciences of Baghdad University
...Show More Authors

The present work aims to investigate approaches, measures and detection of indoor radon level in buildings of the department of physics in college of science of Baghdad University. CR-39 solid state nuclear track detectors were used to measure the radon concentrations inside the rooms, including five laboratories and five workplace rooms in ground and first storey of the department. The average radon concentration at first storey was found to be 43.1±13.2 Bq/m3 and 40.1±13.4 Bq/m3 at the ground storey. The highest level of radon concentration at the first storey in the radioactive sources store was 87.5±29 Bq/m3 while at the ground storey in room(2) was 70.2±24 Bq/m3 which is due to the existence radioactive sources in some selected

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 25 2022
Journal Name
Iraqi Journal Of Science
Geotechnical Assessment of Soil at the Campus Site of College of Science, University of Diyala
...Show More Authors

In this study, some physical and mechanical properties of soil samples collected from the campus site of College of Science, University of Diyalahave been evaluated. All laboratory tests were performed according to the standards of American Society for Testing and Materials (ASTM). The test results showed that the range of soil water content wwas (13.89%-16.34%) with an average of 15.44%. The specific gravity range was (2.58-2.77) with an average of 2.66. The range of Liquid Limit LL was (26.20-35.20%) with an average of 32.22%.The range of Plastic Limit PL was (18.63-23.24%) with average of 21.06%. The range of Plasticity Index was (7.57-12.42) with an average of 11.61. Based on USCS classifications, the soil can be considered

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Engineering
Developing an Indoor Environment Assessment Tool for Residential Buildings
...Show More Authors

The Indoor Environmental Quality (IEQ) describes an indoor space condition that the wellbeing and comfortability are provided for the users. Many researchers have highlighted the importance of adopting IEQ criteria, although they are not yet well defined in the Kurdistan region. However, environmental quality is not necessary for the contemporary buildings of the Kurdistan Region, and there is no measurement tool in the Region. This research aims to develop an IEQ assessment tool for the Kurdistan region using Mixed method methodology, both qualitative and quantitative. Therefore, a Delphi Technique was used as a method initially developed as systematic, interactive forecasting on a panel of experts. Thirty-five Delphi C

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Determination the concentrations of radon gas and exhalation rate in some phosphate fertilizer using CR-39 track detector
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Specific activities and radiation hazard parameters calculations of natural radionuclides in AL-Mustansiriyah university soils using NaI(Tl) detector
...Show More Authors

The specific activities of the natural radionuclides U-238 and Th-
232 and K-40 in 14 soil samples collected from different sites from
AL-Mustansiriyah university at two depths (topsoil "surface" and
20cm depth) were be investigated using gamma ray spectrometer
3"x3" NaI(Tl) scintillation detector.
The analysis of the energy spectra of the soil samples show that
these samples have specific activities ranging with (16.08-51.11)
Bq/kg for U-238, (14.79-52.29) Bq/kg for Th-232 and (191.08-
377.64) Bq/kg for K-40, with an average values of 29.37, 34.14 and
289.62 Bq/kg for U-238, Th-232, k-40 respectively. The radiation
hazard parameters of the natural radionuclides; radium equivalent
activity (Raeq), gamma a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
Measurement of radon gas concentration in water and soil samples in AL-Najaf governorate by using nuclear track detector (CR-39)
...Show More Authors

The radon gas concentration in environmental samples soil and water of selected regions in Al-Najaf governorate was measured by using alpha-emitters registrations which are emitted form radon gas in (CR-39) nuclear track detector. The first part is concerned with the determination of radon gas concentration in soil samples, results of measurements indicate that the highest average radon concentration in soil samples was found in (Al-Moalmen) region which was (100.0±7.0 Bq/m3), while the lowest average radon concentration was found in (Al-Askary) region which was (38.5±4.7 Bq/m3), with an average value of (64.23±14.9 Bq/m3) ,the results show that the radon gas concentrations in soil is below the allowed limit from (ICRP) agency which is (

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Measurement of indoor radon levels and assessment of radiological hazards at Al-Tuwaitha nuclear site and the surrounding area
...Show More Authors

In the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalatio

... Show More
View Publication Preview PDF
Crossref