Preferred Language
Articles
/
ijs-10073
New Mode of On- Line Automation: Chemilumino-Fluoro Metric Method for the Determination of Hydrogen Peroxide by Fluorescence Energy Transfer Using Ploy Acrylic Acid Gel Beads
...Show More Authors

Hydrogen peroxide was determined by a new , accurate , sensitive and rapid method via continuous mode of FIA coupled with total luminescence measurement which include the chemiluminescence generated ,based on the oxidation of Luminol which is loaded on poly acrylic acid gel beads by hydrogen peroxide in presence of Cobalt (II) ion as a chemiluminescence catalyst and the fluorescence that was created by the insitu radiation of the released chemiluminescence light. Fluorescien molecule was used as an accepter fluorophore where it is irradiated internally and instantly by the generation of luminol chemiluminescence light as internal source for irradiation of fluorescien molecule (Fluorescence Energy Transfer (FRET) ) . It can easily give fluorescence light (i.e , no external source for irradiation is used ) at λmax =530 nm. The method is based on the absorbance of the donor molecule (Luminol) by fourteen poly acrylic acid gel beads located in specially designed cell, this cell will measure instantly the emitted light (FRET) . A sample volume of 80 μL was used throughout the whole work. Linear calibration curve extend from 0.1 - 100 μMol .L-1 , with correlation coefficient of 0.9985 and limit of detection L.O.D (S/N =3) 217.60 pg/sample using step wise dilution of the minimum concentration that was achieved by the calibration graph. Repeatability (RSD%) of less than 0.5% for six successive measurement of 50 μMol .L-1 of hydrogen peroxide. The method was applied successively in determination of hydrogen peroxide in some pharmaceutical disinfectants 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 27 2019
Journal Name
Iraqi Journal Of Science
Development of Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on Screen-Printed Carbon Electrode Modified With Silver Nanoparticles
...Show More Authors

     The direct electron transfer behavior of hemoglobin that is immobilized onto screen-printed carbon electrode (SPCE) modified with silver nanoparticles (AgNPs) and chitosan (CS) was studied in this work. Cyclic voltametry and spectrophotometry were used to characterize the hemoglobin (Hb) bioconjunction with AgNPs and CS. Results of the modified electrode showed quasi-reversible redox peaks with a formal potential of (-0.245V) versus Ag/AgCl in 0.1M phosphate buffer solution (PBS), pH7, at a scan rate of 0.1Vs-1. The charge transfer coefficient (α) was 0.48 and the apparent electron transfer rate constant (Ks) was 0.47s-1. The electrode was used as a hydrogen peroxide biosensor with a line

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 29 2018
Journal Name
Iraqi Journal Of Science
A new approximate solution for the Telegraph equation of space-fractional order derivative by using Sumudu method
...Show More Authors

In this work, we are concerned with how to find an explicit approximate solution (AS) for the telegraph equation of space-fractional order (TESFO) using Sumudu transform method (STM). In this method, the space-fractional order derivatives are defined in the Caputo idea. The Sumudu method (SM) is established to be reliable and accurate. Three examples are discussed to check the applicability and the simplicity of this method. Finally, the Numerical results are tabulated and displayed graphically whenever possible to make comparisons between the AS and exact solution (ES).

View Publication Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
International Journal Of Electrochemical Science
Synthesis and Characterization of AlyCu0.15Zn0.85-yFe2O4 Ferrite Prepared by the Sol-Gel Method
...Show More Authors

View Publication
Scopus (15)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
...Show More Authors

A newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor

... Show More
View Publication Preview PDF
Publication Date
Sun May 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Temperature On The Dispersability Of The Grafted Acrylic Acid Onto Alumina Particles
...Show More Authors

 The ability of different alumina-grafted particles was examined for adsorption of phenol and p-chlorophenol under different conditions (i.e. concentrations and temperatures). Dispersion stability of alumina in liquid medium (water) was studied using settling under gravity technique. The result shows the settling initial rate of the alumina-grafted acrylic acid particles was faster than initial rate of settling when alumina-graft acrylic acid monomer adsorbed phenol and p-chlorophenol and vice versa to the alumina-graft poly(acrylic acid) polymer.

Thermodynamic parameters values (DG, DS, DH) were calculated for adsorption processes of phenol and p-chlorophenol adsorbed onto different surfaces. The

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 02 2020
Journal Name
International Journal Of Pharmaceutical Research
A turbidimetric method for the quantitative determination of cyproheptadine hydrochloride in tablets using an optoelectronic detector based on the LEDs array
...Show More Authors

View Publication Preview PDF
Scopus (10)
Crossref (2)
Scopus Crossref
Publication Date
Mon Apr 01 2019
Journal Name
International Journal Of Pharmaceutical Research
Sensitive spectrophoto metric determination of doxycycline in pure and dosage forms using p-bromanil
...Show More Authors

A simple, precise, and sensitive spectrophotometric method has been established for the analysis of doxycycline. The method includes direct charge transfer complexation of doxycycline withp-Bromanil in acetonitrileto form a colored complex. The intensely colored product formed was quantified based on the absorption band at 377 nm under optimum condition. Beer’s law is obeyed in the concentration range of 1–50 μg.mL-1 with molar absorptivity of 1.5725x104 L.mol-1.cm-1, Sandell's sensitivity index (0.0283) μg.cm-2, detection limit of 0.1064 μg.mL-1, quantification limit 0.3224 μg.mL-1 and association constant of the formed complex (0.75x103). The developed method could find application in routine quality control of doxycycline and has

... Show More
Scopus (1)
Scopus
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
New Turbidimetric-Continuous Flow Injection Analysis Method for The Determination of Chlorpromazine HCl in Pharmaceutical Preparation Using Linear Array Ayah 5SX1-T-1D-CFI Analyser
...Show More Authors

A new turbidimetric-flow injection method is described for the determination of chlorpromazine HCl in pure and pharmaceutical preparation. The method is characterized by simplicity, sensitivity and fast, it is based on formation of ion pair compound between chlorpromazine HCl and Potassium hexacyanoferrate(III) in an acid medium for the formation of greenish yellow precipitate. This precipitate was determined using homemade Linear Array Ayah 5SX1-T-1D continuous flow injection analyser. Optimum concentrations of chemical reactants, physical instrumental conditions have been investigated. The linear dynamic range of chlorpromazine HCl was 3-30 mmol.L-1 while correlation coefficient (r) was 0.9929 and percentage linearity (%r2) C.O.D was 9

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Eurasian Chemical Communications
New sensitive turbidimetric method for determination of losartan potassium in pharmaceutical formulations using flow injection combined with homemade turbidimeter
...Show More Authors

Scopus
Publication Date
Fri Sep 05 2014
Journal Name
Engineering And Technology Journal
New Method to Increase the Ability of the Water for Dissolving Total Salts in Soil by Using the Magnetism
...Show More Authors