Preferred Language
Articles
/
ijp-852
Plasma Dynamics and Pulse Shape Rules in Laser Heating of Opaque Targets in Ai
...Show More Authors

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account both plasma dynamics and time variation of incident laser pulse (i.e. pulse shape or profile).Shock tube relations were employed in formulating plasma dynamics over target surface. Gaussian function was chosen in formulating the pulse profile in the present modeling

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 07 2025
Journal Name
Scientific Reports
Evaluation of how laser photostimulation at two wavelengths alters the antimicrobial potential of Streptomycetes spp
...Show More Authors

The purpose of this study was to isolate and identify additional products produced by direct laser irradiation, as well as to ascertain if laser irradiation may stimulate the synthesis of antibiotic compounds in a local Streptomycetes (Strept). Moreover, we postulate the mechanisms by which lasers function within living bacterial cells and suggest that sequential photochemical reactions may transpire following a designated period of irradiation. Thiophene was found as one of the most significant clinical products with antibacterial and anticancer properties. To accomplish these objectives, we selected two isolates: Streptomyces thinghirensis strain S10 (Strept thin), which inherently synthesizes an antibacterial agent, and Streptomyces lien

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Study the Effect of Gold Film Thickness on the Sensitivity of the U Shape Fiber Sensor by the Occurrence of LSPR Phenomenon: Saffana Z. Maseer*, Bushra R. Mahdi
...Show More Authors

Abstract: In this paper, a U-shaped probe with a curvature diameter of half a centimeter was implemented using plastic optical fibers. A layer of the outer shell of the fibers was removed by polishing to a D-section. The sensor was tested by immersing it in a sodium chloride solution with variable refractive index depending on solution concentrations ranging from 1.333 to 1.363. In this design, the sensor experienced a decrease in its intensity as the concentration of the solution increased. The next step The sensor was coated with a thin layer of gold with a thickness of 20 nm, and the sensor was tested with the same solutions which resulted in a shift in wavelengths where the shift in wavelength was 5.37 nm and sensiti

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Effects of Q-switched Nd: YAG laser irradiation on the aqueous solution of human albumin and calf-thymus double strand DNA (ctds)
...Show More Authors

Q-switched lasers widely used in management skin diseases and
sometimes its effect may be inadequate or associated with
cytotoxicity. The current study aimed to investigate the effect of
Q-switched Nd:YAG laser upon cellular elements using in vitro
experimental model. Aqueous solutions of human albumin and pure
calf thymus double strand deoxyribonucleic acid (ctdsDNA)
irradiated with Q-switched Nd:YAG laser at different rates (1, 3 Hz)
and time exposure (up to 60 seconds) using 532 nm (400 mJ) and
1064 (1200 mJ) nm wavelength with fixed spot size of 4 mm. The
effect of laser irradiation on the albumin solution also studied in the
presence of elemental salts of copper, zinc and iron.
Q-switched laser irrad

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 27 2024
Journal Name
Scientific Journal Of Sport And Performance
effect of a laser device on some biomechanical variables of the rotational phase in the achievement of 100 m freestyle swimming for the Iraqi team (16-18 years old)
...Show More Authors

The researchers have discovered weaknesses in the rotational phase of the 100-meter freestyle event, including a lack of proper movement direction and control of biomechanical variables necessary for swimmers to achieve high rotational accuracy, which leads to outperforming competitors. The objective of this study was to investigate the effect of using a laser device on improving the performance of the rotational phase among swimmers on the Iraqi national team. The experimental approach was conducted on a sample of 6 swimmers, representing 100% of the target population. The researchers concluded that the utilization of a proposed laser device in the rotational phase resulted in positive differences in biomechanical variables, contri

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Laser Peening on Aluminum Alloy 7049 Using Black Paint Surface Coating
...Show More Authors

Abstract

Black paint laser peening (bPLP) technique is currently applied for many engineering materials , especially for aluminum alloys due to high improvement in fatigue life and strength . Constant and variable   bending fatigue tests have been performed at RT and stress ratio R= -1 . The results of the present  work observed that the significance of the surface work hardening which generated high negative residual stresses in bPLP specimens .The fatigue life  improvement factor (FLIF)  for bPLP constant fatigue behavior was from 2.543 to 3.3 compared to untreated  fatigue and the increase in fatigue strength at 107 cycle was 21% . The bPLP cumulative fatigue life behav

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 10 2021
Journal Name
Acta Medica Iranica
Early Stages Non-Traumatic Avascular Necrosis of Femoral Head Treated by Core Decompression With and Without Platelets Rich Plasma Injection: A Comparative Study
...Show More Authors

Core decompression is one of the commonest used techniques in the handling of osteonecrosis of the pre-collapsed head of the femur. Core decompression had succeeded in preserving the hip joint and delaying the requisite for total hip replacement, but it had failed in the induction of osteogenesis in the necrotic area, thus augmenting core decompression with biological agents to induce osteogenic activity. To assess the effects of platelet-rich plasma in non-traumatic avascular necrosis of the hip joint (early stage) after core decompression. Interventional comparative study for twenty-four patients (32 hip joints) with AVN of the head of the femur was involved in this prospective study, and they were separated into two groups of 16

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Gamma Ray Effect on the Properties of Coumarin C47 Laser Dye
...Show More Authors

The research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Diyala Journal Of Engineering Sciences
Generation of entangled photons by short coherence length violet diode laser
...Show More Authors

Pumping a BBO crystal by a violet diode laser with a wavelength of (405 nm) output power of (24 mW) and a line width of (3nm) was employed to generate entangled photons with a wavelength of 810 nm by achieving type II phase matching conditions.The coincidence count rate obtained in this experiment was in the range of (18000) counts/s. Two BBO crystals with different thicknesses of (4 mm and 2 mm) were tested, where maximum count rates of about (18000) counts/s was obtained with a (5*5*2) mm BBO crystal where the short coherence time for the pumping source was tolerated by using shorter BBO crystals. Also, the effect of compensating crystal on the walk-off effect was studied. The coincidence count rates were increased by using these crystal

... Show More
View Publication
Publication Date
Thu Jun 10 2010
Journal Name
Iraqi Journal Of Laser
Improvement of Nonlinear Optical Properties for Mixture Laser Dyes Doped PMMA
...Show More Authors

The spectral characteristics and the nonlinear optical properties of the mixed donor (C-480) acceptor (Rh-6G) have been determined. The spectral characteristics are studied by recording their absorption and fluorescence spectra. The nonlinear optical properties were measured by z-scan technique, using Q-switched Nd: YAG laser with 1064 nm wavelength. The results showed that the optimum concentration of acceptor is responsible for increasing the absorption and the emission bandwidth of donor to full range and to 242 nm respectively by the energy transfer process, also the efficiency of the process was increased by increasing the donor and acceptor concentration. The obtained nonlinear properties results of the mixture C-480/ Rh-6G showed

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Excision of Soft Tissue Oral Lesions by 810 nm Diode Laser
...Show More Authors

The present study was conducted on 20 patients suffering from different types of lesion like
pyogenic granuloma, peripheral giant cell granuloma, mucoceles, pregnancy tumour, Fordyce's granules
and irritating fibroma.The cases were selected from outpatient clinic of the Al Kydhemya Teaching
Hospital. Patients were treated by diode laser (810±20 nm) at the affected areas of the oral cavity with
continuous contact focused mode until excision of the lesion with coagulation of the oozing area after
excision. Patients were followed up after 2 days, 7 days and 2 weeks to assess healing process and any
post operative complication. Some of undiagnosed lesion sent for histopathological examination. No
serious complications w

... Show More
View Publication Preview PDF