In the present work, radon gas concentrations in different surface soil samples in Baghdad governorate were measured using RAD-7 detector. The results have been shown that, the Radon gas concentrations ranged between (41.67±1.78Bq/m3), to (185.67±4.22Bq/m3), a map showing the distribution of the concentration of radon in selected areas was defined to identify areas with high pollution level. The reason for the high concentration of radon is that these surface soil samples are taken from agricultural areas. It is also known that fertilizers contain uranium levels as well as areas bombed in wars in the country. It is worth noting that all radon concentrations in Baghdad governorate are below the recommended minimum of 200-300Bq/m3) (International Commission on Radiation Protection, ICRP, 2009).
In this study, the radon gas concentration as well as the annual effective dose in leaves of the Malvasylvestris (Khabbaz) plant used in the traditional treatment and as food in Iraq, for this, it is necessary to evaluate the concentrations radon gas, which were measured using solid state nuclear track detectors (SSNTDs) CR-39 technique. The concentration and annual effective dose in samples were collected from Baghdad city ranged from minimum to maximum value 15.815 , 0.498 , 54.445 , 1.717 respectively, while the values of concentration and annual effective dose in a sample collected from Karbala are 15.297 ,0.482 . These values of concentration and annual effective dose less were compared with th
... Show MoreIn present study, the technique was used, including nuclear track detector type (CR-39), for appreciative concentrations uranium and radon in soil samples from Baghdad University Campus-AL-Jadiriyah utilizing a prolonged -term with a solid-state nuclear path sensor, a technique for charged particles has been developed., the radon concentrations, effective dose rate and uranium concentrations have measured in soil samples. Eight various venues from soil Baghdad University Campus have appointed. The results indicated variant values about uranium and radon concentrations, the average value for radon gas, effective dose rate and uranium concentrations was found to be 281.59 Bq/cm3, 7.09 mSv/y and 0.01 Bq/mm-2 respectively. All results a
... Show MoreEstimation of elements: Pb, Zn, Mn, Cd, and Cu, which were conducted seasonally from October-2021 till March-2022 in residential areas of Baghdad City using Geoaccumulation index (Igeo), enrichment factor ratios (EF), the factor of contamination (CF), contamination degree (Cd), index of pollution load (PLI) and index of potential ecological risk (Eif). The overall contamination factor in the research area is limited from low contamination with Cu, Mn, and Zn, moderately contaminated to very high contamination with Pb and Cd, while the assessment according to the I-geo index shows categories that vary from a slightly polluted to unpolluted by those examined heavy metals. The pollution load index indicates that the soils in some resi
... Show MoreIn the present study, radon gas concentration in the shallow groundwater samples of the Abu-Jir region in Anbar governorate was measured by using Rad-7 detector. The highest radon gas level in the samples is up to 9.3 Bq/L, while the lowest level is 2.1 Bq/L, with an average of 6.44±1.8 Bq/L. The annual effective dose is varied from 33.945 μSv/y to 7.66 μSv/y, with an average of 0.145±0.06 μSv/y. Consequently, the radon level in the groundwater studied is lower than the standard recommended value (11 Bq/L) reported by the United States Environmental Protection Agency (USEPA). The potential source of radon is uranium-rich hydrocarbons that are leakage to the surface along the Abu-Jir Fault. This research did not indicate any ris
... Show MoreAbstract: The aim of the present work is to measure radon concentration in wood. Solid state nuclear track detectors of type CR – 39 was used as measurement device. Eight different samples of imported and local wood were collected from markets. Samples were grinded, dried in order to measure radon concentrations in it. Cylindrical diffusion tube was used as detection technique. Results show that the higher concentration was in Iraqi sample 1 which recorded (14.02 ± 0.9) Bq / m3, while the less was in Emirates Sample which recorded (5.35 ± 1.2) Bq / m3. From the present work, all wood samples were with lowest concentrations of radon gas than other building materials.
In this study a concentration of uranium was measured for twenty two samples of soil distributed in many regions (algolan, almoalmeen, alaskary and nasal streets) from Falluja Cityin AL-Anbar Governorate in addition to other region (alandlos street) as a back ground on the Falluja City that there is no military operations happened on it. The uranium concentrations in soil samples measured by using fission tracks registration in (PM-355) track detector that caused by the bombardment of (U) with thermal neutrons from (241Am-Be) neutron source that has flux of (5×103n cm-2 s-1). The concentrations values were calculated by a comparison with standard samples. The results shows that the uranium concentrations algolan street varies from(1.
... Show More