During the winter, in the industry region (Shaikh Omer) and by applying a passive radon detector (CR-39), lung cancer risk has been measured in twelve rooms of different workshops of two old factories in this site. The radon concentration is ranged from (123.345 Bq/m3) to (328.985 Bq/m3) with an average of (244.19±61.52 Bq/m3). Lung cancer risk ranged from 55.993 to 149.346 per million people and with an average of (110.855 per million people) which were lower than the recommended values (170-230 per million people), so there was no cancer risk on workers in these locations.
In this research, the concentration of radon gas has been calculated in the classrooms of schools in Diyala Governorate by using the nuclear track detector (CR-39), which was one of the organic solid-state nuclear detectors (SSNTDs). After calculating the radon gas concentration, the lung cancer cases were calculated. The results showed that the lowest value was found in (Alshumue) school (4.753) people. In contrast, the highest value was found in (Habhib) school (20.421). The average values of lung cancer cases in Diyala governorate were equal to (9.319) per person. The results showed that the number of lung cancer cases per year per million persons in Diyala Governorate schools was below the allowed limit from (ICRP) agency (170-230) p
... Show MoreIn this research the activity of radon gas in air in Baghad governorate,Iraq, using “alpha-emitters track registration (CR-39) track detector were measured. This measurement was done for selected areas from Baghdad Governorate, The results obtained shows that the highest average concentrations for Rn-222 is (179.077 Bq/m^3) which was recorded within Al-Shaaib city and less average concentrations was (15.79 Bq/m^3) in the nearby residential area of Baghdad International Airport and the overall average concentrations is (86.508 Bq/m^3) for these regions. Then the radon concentration was measured annual effective dose calculated from radon concentration and found in range from 0.4031 mSv/y to 4.5179 mSv /y with an average value of 2.1824 m
... Show MoreConcentration of NORM then radiological hazard indices were investigated and assessed in different stages of oil and gas production industry that belongs to East Baghdad Oil Field. Sixteen samples of different types of materials were collected representing oil and gas production from first stage to final stage. The samples are prepared then sent to Radiation Protection Center (RPC) / Ministry of Environment for radioactivity analysis using gamma ray spectrometry system based on HPGe. The results show that max value of Ra-226 is 252.4 Bq/kg in sediment sample collected from the final stage of water treatment before it is transferred to disposal well and min value is 1.2 Bq/kg in formation water. The max. activity of Th-232 is 79.4Bq/kg al
... Show MoreInstruments for the measurements of radon, thoron and its decay
products in air are based mostly on the detection of alpha particles.
The health hazards of radon on general public are well known. In
order to understand the level and distribution of 222Rn concentrations
indoor in Al-Fallujah City; new technique was used, this technique
was three radon–thoron mixed field dosimeters is made up of a twin
chamber cylindrical system and three LR-115 type II detectors were
employed. The aim of this work was to measurement radon gas using
SSNTD technique door in in Al-Fallujah City, and estimation of
excess in cancer due to increment in radon gas. Results for samples
which are collected from January to
In the present work, radon gas concentrations in different surface soil samples in Baghdad governorate were measured using RAD-7 detector. The results have been shown that, the Radon gas concentrations ranged between (41.67±1.78Bq/m3), to (185.67±4.22Bq/m3), a map showing the distribution of the concentration of radon in selected areas was defined to identify areas with high pollution level. The reason for the high concentration of radon is that these surface soil samples are taken from agricultural areas. It is also known that fertilizers contain uranium levels as well as areas bombed in wars in the country. It is worth noting that all radon concentrations in Baghdad governorate are below the recommended minimum of 200-300Bq/m3) (Inte
... Show MoreIn this work, radon concentrations in the polluted environment were measured within the Baghdad sample surface soil conservation, and this was done using a RAD-7 mobile detector. The work consists of four parts:
The first part includes calculating the latitude and longitude of each point of the study area using the Global Positioning System (GPS). The second part of which includes Determination of 222Rn gas concentrations in surface soil samples. In the northeast part of Baghdad, the highest concentration of radon was found in Al-
Shaab area (3.11 ±175.33 Bq / m3), while the lowest gas concentration in AL Gzeera area (6.67±73.00 Bq/ m3), In the northwest part of Baghdad, the highest concentratio
Hookah smoking has become very popular in Iraq among women and men. Hookah tobacco contains natural radioactive elements, such as radon, radium, and uranium, as well as toxic elements, such as polonium, which are released during the combustion of tobacco and are inhaled by smoking. Most reviews focus on hookah tobacco, and only a few have investigated the blood of hookah smokers. In this study, a CR-39 detector was used to measure radon, radium, and polonium concentrations and conduct risk assessments in female hookah smokers of different ages. The results show that the concentrations of radon-222, polonium-218, and polonium-214 varied between 61.62 and 384.80, 5.45–33.64 on the wal
Radon and its daughters are of the natural radioactive decay of the uranium series. Exposure to radon gas leads to lung cancer, so the risks are significantly higher for smokers than for non-smokers. Therefore, the risk of radon increases for both active and passive smokers. The radioactivity of alpha particles emitted by radium 226, the main source of radon 222, has become harmful because its prevalence and inhalation increase with increased smoking. In this study, a CR-39 detector was used to measure radon, radium, and uranium concentrations and then calculate risk parameters in seven cigarette-smoking females in vitro study of human blood samples, and three normal females with no actual and passive cigarette smoking. The rado
... Show MoreAbstract
In this study the radon gas concentration in air in Al - Haswaa city in province of Baghdad in Iraq have been calculated using CR-39 solid–state nuclear track detector technique. A total of 8 samples selected from 8 region in Al – Haswaa city in province of Baghdad have been placed in the dosimeters for 30 day. The average radon gas concentration was found to be 486.26 Bq/m3 which is lower than the standard international limit (1100 Bq/m3). The potential alpha energy concentration and annual effective dose have been calculated. A proportional relationship between the annual effective dose and radon gas concentration within the studied region has been certified.