In this research, the influence of the orientation and distance factors on the lowest usable frequency (LUF) parameter has been studied theoretically. The calculations of the (LUF) parameter have been made using the (VOACAP) international communication model for the connection links between the capital Baghdad and many other locations that distributed on different distances and directions over the Middle East region. The results shown in this study indicate there is a slight affection of the link direction (orientation) on the LUF parameter, while the influence of the distance factor is more significant on the values of the LUF parameter. The day/night effect appears for the long distance HF links (i.e. more than a 500 Km)
The paper presents research results of the vibration transmitted from the steering wheel of the
tractor with a 2-wheel drive to the driver’s hands. The vibration measurements were carried out on the
tractor randomly chosen from the collage of agriculture / university of Baghdad. Before testing the
tractor was examined and adjusted following the producer’s recommendations. The vibration levels
were measured during the operation tillage at idling and at full load .The field was 3١٫٧ m above level
sea. Soil was treated at soil constant moisture (1٧-20 %) with depth of plowing (١٧ cm). During
operation the weather temperature was measured (15 C) and humidity was ( 27 % ) The vibration level
on the steering whee
Experimental work was carried out to investigate the effect of fire flame (high temperature) on specimens of one way slabs using Self Compacted Concrete (SCC). By using furnace manufactured for this purpose, twenty one reinforced concrete slab specimens were exposed to direct fire flame. All of specimens have the same dimensions. The slab specimens were cooled in two types, gradually by left them in the air and suddenly by using water. After that the specimens were tested under two point loads, to study, the effect of
different: temperature levels (300ºC, 500ºC and 700ºC), and cooling rate (gradually and sudden cooling conditions) on the concrete compressive strength, modulus of rupture, flexural strength and the behavior of reinf
Background: One way to target polypharmacy and inappropriate medication in hemodialysis (HD) patients is with medication deprescribing. Objective: To assess the impact of implementing a pharmacist-led deprescribing program on medication adherence among HD patients. Method: A prospective interventional, one-group pretest-posttest-only design study was conducted at a hemodialysis center in Wasit Governorate, Iraq. Medication reconciliation followed by medication review based on the deprescribing program was done for all eligible patients, and the patients were monitored for three months for any possible complications. Results: Two hundred and seventy patients were screened for eligibility. Only one hundred and eighteen were enrolled i
... Show MorePurpose To test the effect of strategic Supremacy on strategic success A case study in Thi Qar Governorate, methodology/approach – this is a mandatory entry.
a case study was used and applied to the Department managers of Government of the province of Thi Qar, Research limitations/implications – It is clear that the strategic Supremacy variable is not being used effectively to achieve strategic success.
Practical implications – use strategic supremacy positively to Support for strategic success. implementing and monitoring ignorance of them in how to use thi
... Show MoreThe purpose of this study was to determine the influence of environmental pH on production of biofilms and virulence genes expression in Pseudomonas aeruginosa.
Among 303 clinical and environmental samples 109 (61 + 48) isolates were identified as clinical and environmental P. aeruginosa isolates, respectively. Clinical samples were obtained from patients in the Al-Yarmouk hospital in Baghdad city, Iraq. Waste water from Al-Yarmouk hospital was used from site before treatment unit to collect environmental samples. The ability of prod
Kurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.
The effects of three different additives formulations namely Lubrizol 21001, HiTEC 8722B and HiTEC 340 on the efficiency of VII namely OCP of three base lubricating oils namely 40 stock and 60 stock and 150 stock at four temperatures 40, 60, 80 and 100oC were investigated. The efficiency of OCP is decreased when blended with 4 and 8 wt% of Lubrizol 21001 for all the three base oil types. But it is increased when adding 4 wt% and 8 wt% of H-8722B in 40 stock. While for 60 stock and 150 stock the OCP efficiency decreased by adding 4 and 8 wt% of H-8722B. In the other hand, it is decreased with a high percentage by adding 4 and 8 wt% of H-340 for 60 stock and 150 stock and for 40 stock it is increased by adding 4 wt% of H-340 and decreased
... Show MoreThe chlorine concentration variation in Baghdad water networks was studied. The
chlorine data were collected from Mayoralty of Baghdad and Ministry of Environment
(MOE) for the networks for both sides of the city Karkh and Rasafa for (2008-2009). The
study of these data indicates that there are no systematic testing program .Classified GIS
maps showed that the areas far from the treatment plants have almost always low
chlorine concentration .This indicates that the problem of the low chlorine concentration
in the far areas is due to cracks of pipe along the conveyance path ,as expected. The area's
most frequently have low concentration are Al-sadir,Al-Kadhimya, and Al-Amiria . It
was found also that the chlorine c
The water supply network inside the building is of high importance due to direct contact with the user that must be optimally designed to meet the water needs of users. This work aims to review previous research and scientific theories that deal with the design of water networks inside buildings, from calculating the amount of consumption and the optimal distribution of the network, as well as ways to rationalize the use of water by the consumer. The process of pumping domestic water starts from water treatment plants to be fed to the public distribution networks, then reaching a distribution network inside the building till it is provided to the user. The design of the water supply network inside the building is
... Show More