Preferred Language
Articles
/
ijl-136
Evaluation of breast mass excision by 810 nm diode laser
...Show More Authors

Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range of cutting was 2-3 mm. The speed of cutting was 0.6 cm/s. In the clinical work, the power needed for excision was 15 W (5.3 kW/cm2 power density). Power used for coagulation was ranging between 10-15W depending on diameter of blood vessel, the overall blood loss during surgery and postoperatively appeared to be less than that in conventional method. The contact laser scalpel produced clear appearance of surgical margin and saved dissection. Hemostatic capability assured clear anatomical visualization and few ligatures. No clinical evidence of infection at the wound site postoperatively. The results showed that the diode laser is effective in minimizing the intra-operative blood loss, postoperative blood loss, and effective in reducing the postoperative pain, swelling and edema. On follow up the patients were presented with relatively better healing progress, no wound infections, and no need for strong pain killer postoperatively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
The Structure and Optical Properties of Ag doped CdO Thin Film Prepared by Pulse Laser Deposition (PLD)
...Show More Authors

At a temperature of 300 K, a prepared thin film of Ag doped with different ratios of CdO (0.1, 0.3, 0.5) % were observed using pulse laser deposition (PLD). The laser, an Nd:YAG in ?=1064 nm, used a pulse, constant energy of 600 mJ ,with a repetition rate of 6 Hz and 400 pulses. The effect of CdO on the structural and optical properties of these films was studied. The structural tests showed that these films are of a polycrystalline structure with a preferred orientation in the (002) direction for Ag. The grain size is positively correlated with the concentration of CdO. The optical properties of the Ag :CdO thin film we observed included transmittance, absorption coefficient, and the energy gap in the wavelength range of 300-1100

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Apr 01 2019
Journal Name
The Saudi Dental Journal
Implementation and characterization of coating pure titanium dental implant with sintered β-TCP by using Nd:YAG laser
...Show More Authors

Objectives This work presents laser coating of grade 1 pure titanium (Ti) dental implant surface with sintered biological apatite beta-tricalcium phosphate (β-TCP), which has a chemical composition close to bone. Materials and methods Pulsed Nd:YAG laser of single pulse capability up to 70 J/10 ms and pulse peak power of 8 kW was used to implement the task. Laser pulse peak power, pulse duration, repetition rate and scanning speed were modulated to achieve the most homogenous, cohesive and highly adherent coat layer. Scanning electron microscopy (SEM), energy dispersive X-ray microscopy (EDX), optical microscopy and nanoindentation analyses were conducted to characterise and evaluate the microstructure, phases, modulus of elasticity

... Show More
View Publication
Scopus (26)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Acta Facultatis Medicae Naissensis
A correlation between body mass index and refractive errors
...Show More Authors

Background. Body mass index (BMI) is a person's weight in kilograms (or pounds) divided by the square of height in meters (or feet). Obesity affects a wide spectrum of age groups, from the young to the elderly, and there are several eye diseases related to obesity like diabetic retinopathy, floppy eyelid syndrome, retinal vein occlusion, stroke-related vision loss, age-related macular degeneration, and possibly, refractive errors. Refractive errors (RE) are optical imperfections related to the focusing ability of the eye and are the main cause of visual impairment which may result in missed education and employment opportunities, lower productivity and impaired quality of life. Aim. The study aimed to find an association between bod

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Volumetric Mass Transfer Capacity Coefficient in the RTL Extractor
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Medical Toxicology & Legal Medicine
The relationship between body mass index and asthma control
...Show More Authors

Asthma and obesity are both a major public health problems affecting large numbers of individuals across the globe. Link between obesity and asthma is now considered as a recognized fact, and many epidemiological studies, found that overweight and obese people had a higher chance of developing asthma, with more severe symptoms. Assessment of the relationship between body mass index and asthma control. A cross-sectional study, that included 100 patients diagnosed with asthma, attending the respiratory disease consultatory unit at Baghdad teaching hospital. Body mass index was calculated by (BMI= weight in Kg/Height in m2), and Asthma control was assessed using asthma control test questionnaire forma. Statistical analysis done using, Test of

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Aug 01 2021
Journal Name
Laser Micro- And Nano-scale Processing
Physical principles of laser–material interaction regimes for laser machining processes
...Show More Authors

Lasers, with their unique characteristics in terms of excellent beam quality, especially directionality and coherency, make them the solution that is key for many processes that require high precision. Lasers have good susceptibility to integrate with automated systems, which provides high flexibility to reach difficult zones. In addition, as a processing tool, a laser can be considered as a contact-free tool of precise tip that became attractive for high precision machining at the micro and nanoscales for different materials. All of the above advantages may be not enough unless the laser technician/engineer has enough knowledge about the mechanism of interaction between the laser light with the processed material. Several sequential phenom

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of laser energy and pulses on size and concentration of gold nanoparticles in DDDW by LALP method
...Show More Authors

The size and the concentration of the gold nanoparticles (GNPs)
synthesized in double distilled deionized water (DDDW) have been
found to be affected by the laser energy and the number of pulses.
The absorption spectra of the nanoparticles DDDW, and the
surface plasmon resonance (SPR) peaks were measured, and found to
be located between (509 and 524)nm using the UV- Vis
spectrophotometer. SPR calculations, images of transmission
electron microscope, and dynamic light scattering (DLS) method
were used to determine the size of GNPs, which found to be ranged
between (3.5 and 27) nm. The concentrations of GNPs in colloidal
solutions found to be ranged between (37 and 142) ppm, and
measured by atomic absorptio

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
effect of doping with nitrogen on the optical constant of the sic films prepared by TEA-Co2 Laser
...Show More Authors

In this research prepare membranes pure silicon carbide (SiC) as well as gas Alloy (ammonia) and using a laser was leaked membrane of glass flooring. To Drasesh optical properties of membranes prepared depending on the technique (Swanepoel) and Adhrt results obtained in general increased permeability pure silicon membranes

View Publication Preview PDF
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Effect of thickness on the optical properties of ZnO thin films prepared by pulsed laser deposition technique (PLD)
...Show More Authors

Zinc Oxide (ZnO) thin films of different thickness were prepared
on ultrasonically cleaned corning glass substrate, by pulsed laser
deposition technique (PLD) at room temperature. Since most
application of ZnO thin film are certainly related to its optical
properties, so the optical properties of ZnO thin film in the
wavelength range (300-1100) nm were studied, it was observed that
all ZnO films have high transmittance (˃ 80 %) in the wavelength
region (400-1100) nm and it increase as the film thickness increase,
using the optical transmittance to calculate optical energy gap (Eg
opt)
show that (Eg
opt) of a direct allowed transition and its value nearly
constant (~ 3.2 eV) for all film thickness (150

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Calculation the mass attenuation coefficient of beta-particles through Polyvinyl chloride
...Show More Authors

The mass attenuation coefficient for beta particles through pure Polyvinyl chloride (PVC) and flax fibers- reinforced PVC composite were investigated as a function of the absorber thickness and the absorber to source distance. The beta particles mass attenuation coefficients were obtained using a NaI(Tl) energy selective scintillation counter with 90Sr/ 90Y beta source having an energy range from (0.546-2.275) MeV. Pure PVC polymer samples were prepared by compacting the PVC powder in a mould at high pressure (10bar) and temperature about 140°C for 30 minutes. A hot press system was used for this process. The experimentally obtained values of mass attenuation coefficients for 90Sr and 90Y were found to be 7.72 cm2.g-1and 0.842 cm2.g-1 r

... Show More
View Publication Preview PDF