Preferred Language
Articles
/
ijcpe-634
Removal of Wool Dyes from Industrial Wastewater by Reverse Osmosis Process
...Show More Authors

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 03 2022
Journal Name
Egyptian Journal Of Chemistry
Improving Biogas Production from Rice Husk Waste by Mixing with Pomegranate peels Waste by using Anaerobic Digestion
...Show More Authors

Biogas is one of the most important sources of renewable energy and is considered as an environment friendly energy source. The major goal of this research is to see if rice husk (Rh) waste and pomegranate peels (PP) waste are suitable for anaerobic digestion and what effect NaOH pre-treatment has on biogas generation. Rice husk and pomegranate peels were tested in anaerobic digestion under patch anaerobic conditions as separate wastes as well as blended together in equal proportions. The cumulative biogas output for the blank test (no pretreatment) was 1923 and 2526 ml, respectively using a single rice husk (Rh) and pomegranate peel (PP) substrates. The 50% rice husk digestion and 50% of pomegranate peels for blank test gave the result 224

... Show More
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
Study the Impact of Silica Nanoparticles on the Properties of Several Dyes for the Fabrication of a Random Laser Gain Medium
...Show More Authors

Random laser gain media is synthesized with different types of dye at the same concentration (1×10-3 M) as an active material and silicon dioxide NPs (silica SiO2) as scatter centers through the Sol-Gel technique. The prepared samples are tested with UV–Vis spectroscopy, Fluorescence Spectroscopy, Field Emission Scanning Electron Microscopy (FESEM), and Energy Dispersive X-ray Diffraction (EDX). The end result demonstrates that doped dyes with silica nanoparticles at a concentration of 0.0016 mol/ml have lower absorbance and higher fluorescence spectra than pure dyes. FESEM scans revealed that the morphology of nanocrystalline silica is clusters of nano-sized spherical particles in the range (25-67) nm. It is con

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Development and Validation of a Simple and Sensitive Reverse-Phase High Performance Liquid Chromatographic Method for the Determination of Ibuprofen in Pharmaceutical Suspensions
...Show More Authors

The aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (ICH) requirements. The chromatographic parameters were as follows: column of octyldecylsilyl C18 with dimensions (150 × 4.6) mm, mobile phase composed of acetonitrile with phosphoric acid with a ratio of 50 to 50 each using isocratic mode, flow rate of 1.5 mL/min and injection volume of 5 μL. The detection was carried out using UV detector at 220 nm. The method was validated and showed short retention time for ibuprofen peak at 7.651 min, wit

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Apr 17 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
10.28936 STUDY OF THE KINETIC AND ADSORPTION ISOTHERM PARAMETERS FOR REMOVING COPPER AND IRON IONS FROM AQUEOUS SOLUTIONS BY USING AGRICALTURAL BY-PRODUCTS.: STUDY OF THE KINETIC AND ADSORPTION ISOTHERM PARAMETERS FOR REMOVING COPPER AND IRON IONS FROM AQUEOUS SOLUTIONS BY USING AGRICALTURAL BY-PRODUCTS.
...Show More Authors

Wheat straw was modified with malonic acid in order to get low cost adsorbent have a good ability to remove copper and ferric ions from aqueous solutions, chemical modification temperature was 120°C and the time was 12 h. Parameters that affect the adsorption experiments were studied and found the optimum pH were 6 and 5 for copper and iron respectively and the time interval was 120 min and the adsorbent mass was 0.1 g. The values for adsorption isotherms parameters were determined according to Langmuir [qmax were 54.64 and 61.7 mg/g while b values were 0.234 and 0.22 mg/l] , Freundlich [Kf were 16.07 and 18.89 mg/g and n were 2.77 and 3.16], Temkin [B were 0.063 and 0.074 j/mol and At were 0.143 and 1.658 l/g] and for Dubinin-Radushkev

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
The Effect of Authentic Leadership In Business Process Reengineering
...Show More Authors

Abstract  :

The present study aims at identifying the status of the two research variables in the organization under study and specifying the relationship and impact of the authentic leadership with all its four branch dimensions of (self-awareness, transparent relations, balanced processing of information and the moral perspective) on business process reengineering.

The basic problem of the study lies in the attempt to present a new leadership style that is more responsive to the dynamic changes surrounding it based on the authentic leadership behaviors. This is because this pattern has an impact on the nature of the organization's work and its progress.

The research

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Estimation of Mass Transfer Coefficient for Copper Electrowinning Process
...Show More Authors

Mass transfer was examined at a stationary rectangular copper electrode (cathode) by using the reduction of cupric ions as the electrochemical reaction. The influence of electrolyte temperature (25, 45, and 65 oC), and cupric ions concentration (4, 8, and 12 mM) on mass transfer coefficient were investigated by using limiting current technique. The mass transfer coefficient and hence the Sherwood number was correlated as Sh =

 

View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
The role of modern manufacturing systems in process Design
...Show More Authors

The aim of the research to measure the correlation relationship between modern manufacturing systems and process design and measure the effect by adopting the regression; the research consists of two main variables, which are modern manufacturing systems and process design; it was applied in the production lines of the General Company for Construction Industries, There is a sample of managers, engineers, technicians, administrators, and some workers were selected to fill the special questionnaire with (70) forms which distributed and (65) were approved suitable for use, For data analysis the correlation coefficient was adopted to measure the relationship and regression analysis to find out the effect, Using (SPSS), So the first h

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Valuable Metals From Spent Hydrodesulfurization Catalyst By Two Stage Leaching Method
...Show More Authors

Spent hydrodesulfurization (Co-Mo/γ-Al2O3) catalyst generally contains valuable metals like molybdenum (Mo), cobalt (Co), aluminium (Al) on a supporting material, such as γ-Al2O3. In the present study, a two stages alkali/acid leaching process was conducted to study leaching of cobalt, molybdenum and aluminium from Co-Mo/γ-Al2O3 catalyst. The acid leaching of spent catalyst, previously treated by alkali solution to remove molybdenum, yielded a solution rich in cobalt and aluminium.

View Publication Preview PDF